Swan-Ganz catheter-induced pseudoaneurysm of the pulmonary artery

被引:0
|
作者
Tomoki Utsumi
Tetsuo Kido
Toshihiro Ohata
Motoaki Yasukawa
Hiroshi Takano
Tetsuo Sakakibara
机构
[1] Osaka Police Hospital,Department of Cardiovascular Surgery
[2] Osaka Police Hospital,Division of General Thoracic Surgery
关键词
pseudoaneurysm; pulmonary artery; Swan-Ganz catheter;
D O I
10.1007/BF03032630
中图分类号
学科分类号
摘要
Pseudoaneurysm of the pulmonary artery (PA) induced by Swan-Ganz catheter injury is an important complication with high mortality. We report a case of PA pseudoaneurysm treated by PA repair. A 52-year-old woman developing infiltrate in the right lung field in chest radiography after a second mitral valve replacement was diagnosed with PA pseudoaneurysm confirmed by contrast-enhanced computed tomography and pulmonary angiography. The cause was considered Swan-Ganz catheter injury. The patient was carefully observed because there was no evidence of bronchial hemorrhage. The perforation was closed and the cavity plicated under extracorporeal circulation to avoid delayed rupture of the pseudoaneurysm when she underwent a third mitral valve replacement.
引用
收藏
页码:347 / 349
页数:2
相关论文
共 50 条
  • [41] Swan song for the Swan-Ganz catheter?
    Soni, N
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1996, 313 (7060): : 763 - 764
  • [42] False aneurysm of the pulmonary artery induced by a Swan-Ganz catheter: Clinical presentation and radiologic management
    Ferretti, GR
    Thony, F
    Link, KM
    Durand, M
    Wollschlager, K
    Blin, D
    Coulomb, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) : 941 - 945
  • [43] IMPROVED TECHNIQUE FOR BEDSIDE INSERTION OF SWAN-GANZ PULMONARY-ARTERY CATHETER
    BAILEY, LL
    SONDHEIMER, HM
    BLOOM, KR
    WILLIAMS, WG
    [J]. ANNALS OF THORACIC SURGERY, 1976, 21 (05): : 460 - 461
  • [44] HAZARDS OF THE SWAN-GANZ CATHETER
    ROBIN, ED
    [J]. ANNALS OF INTERNAL MEDICINE, 1988, 108 (01) : 151 - 151
  • [45] THOUGHTS ON THE SWAN-GANZ CATHETER
    BRANDSTETTER, RD
    GITLER, B
    [J]. CHEST, 1986, 89 (01) : 5 - 6
  • [46] KNOTTING OF A SWAN-GANZ CATHETER
    GRAYBAR, GB
    ADLER, E
    SMITH, W
    PUYAU, FA
    [J]. CHEST, 1983, 84 (02) : 240 - 240
  • [47] Knotted Swan-Ganz catheter
    Mera Velasco, Santiago
    Rodriguez Canete, Alberto
    Ruiz Lopez, Manuel
    Santoyo Santoyo, Julio
    [J]. CIRUGIA ESPANOLA, 2010, 87 (02): : 113 - 113
  • [48] SWAN-GANZ CATHETER - RESPONSE
    BACIEWICZ, FA
    [J]. INTENSIVE CARE MEDICINE, 1988, 14 (03) : 254 - 254
  • [49] SWAN-GANZ CATHETER - REVIEW
    HATHAWAY, R
    [J]. NURSING CLINICS OF NORTH AMERICA, 1978, 13 (03) : 389 - 407
  • [50] SNARING OF A SWAN-GANZ CATHETER
    BLOCK, PC
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 71 (06): : 917 - 919