Seismic behavior of RC moment resisting structures with concrete shear wall under mainshock–aftershock seismic sequences

被引:0
|
作者
Omid Karimzade Soureshjani
Ali Massumi
机构
[1] Kharazmi University,
来源
关键词
Mainshock–aftershock; Seismic sequences; Shear wall; Reinforced concrete; Seismic behavior; Nonlinear behavior; Ratio of aftershock PGA to mainshock PGA;
D O I
暂无
中图分类号
学科分类号
摘要
A structure may be subject to several aftershocks after a mainshock. In many seismic design provisions, the effect of the seismic sequences is either not directly considered or has been underestimated. This study examined the seismic behavior of reinforced concrete (RC) moment-resisting structures with concrete shear walls under seismic sequences. Two three-dimensional structures of short and medium height were designed and analyzed under seven real mainshock–aftershock seismic sequences. The models were loaded and designed according to the Iranian seismic code (4th ed.; Standard No. 2800) and ACI-318. The structures were analyzed using the nonlinear explicit finite element method. The maximum displacement, inter-story drift ratio, residual displacement, and ratio of aftershock PGA to mainshock PGA were investigated and assessed. Because of the high lateral stiffness of the shear walls in addition to their completely elastic behavior, the aftershocks did not increase the inter-story drift ratio or relative displacement in the short structure model. The medium height model under the seismic sequences showed a significant growth in the relative displacement (roughly 25% in some cases), inter-story drift ratio, plastic strain, and residual displacement (42.22% growth on average) compared to the structure that was only subjected to the mainshock. Remarkably, in some cases, the aftershock doubled the residual displacement. Unlike the moment-resisting frames under seismic sequences, the models showed no significant growth in the drift ratio with an increase in height. Assessments indicated that the ratio of aftershock PGA to mainshock PGA is a determinative parameter for structural behavior under seismic sequences, such that high values of this ratio (> 0.6) caused significant increases in the residual and relative displacements.
引用
收藏
页码:1087 / 1114
页数:27
相关论文
共 50 条
  • [21] Seismic assessment and rehabilitation of a RC structure under mainshock-aftershock seismic sequences using beam-column bonded CFRP strategy
    Omid Karimzade Soureshjani
    Gholamreza Nouri
    Bulletin of Earthquake Engineering, 2022, 20 : 4989 - 5016
  • [22] Seismic assessment and rehabilitation of a RC structure under mainshock-aftershock seismic sequences using beam-column bonded CFRP strategy
    Soureshjani, Omid Karimzade
    Nouri, Gholamreza
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (10) : 4989 - 5016
  • [23] SEISMIC EVALUATION OF CODE DESIGNED STEEL PLATE SHEAR WALLS UNDER MAINSHOCK-AFTERSHOCK EARTHQUAKE SEQUENCES
    Favretto, Nik
    Chen, Cheng
    SUSTAINABLE SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2014, : 121 - 126
  • [24] Seismic Performance Assessment of SMRF Structures Subjected to Mainshock-Aftershock Seismic Sequences by Endurance Time Method
    Farivarrad, Amir H.
    Estekanchi, Homayoon E.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (07) : 3281 - 3299
  • [25] Seismic analysis method of unreinforced masonry structures subjected to mainshock-aftershock sequences
    Zhang, Yongqun
    Wang, Zhuolin
    Jiang, Lixue
    Skalomenos, Konstantinos
    Zhang, Dongbo
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (05) : 2619 - 2641
  • [26] Seismic analysis method of unreinforced masonry structures subjected to mainshock-aftershock sequences
    Yongqun Zhang
    Zhuolin Wang
    Lixue Jiang
    Konstantinos Skalomenos
    Dongbo Zhang
    Bulletin of Earthquake Engineering, 2022, 20 : 2619 - 2641
  • [27] Seismic fragility assessment of aqueduct bent structures subjected to mainshock-aftershock sequences
    Du, Min
    Zhang, Sherong
    Wang, Chao
    She, Lei
    Li, Jiabei
    Lu, Tong
    ENGINEERING STRUCTURES, 2023, 292
  • [28] Seismic fragility analysis of masonry structures considering the effect of mainshock-aftershock sequences
    Zhang, Yongqun
    Wang, Zhuolin
    Jiang, Lixue
    Skalomenos, Konstantinos
    Zhang, Dongbo
    ENGINEERING STRUCTURES, 2023, 275
  • [29] Seismic damage accumulation in multiple mainshock-aftershock sequences
    Iervolino, Iunio
    Chioccarelli, Eugenio
    Suzuki, Akiko
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2020, 49 (10): : 1007 - 1027
  • [30] Effect of base shear ratios between moment-resisting frames and shear walls on the seismic behavior factor of RC dual structures
    Louzai A.
    Abed A.
    Asian Journal of Civil Engineering, 2023, 24 (8) : 2863 - 2878