Whole-cell optical biosensor for mercury — operational conditions in saline water

被引:0
|
作者
Andrey Solovyev
Gabriela Kuncova
Katerina Demnerova
机构
[1] Institute of Chemical Process Fundamentals ASCR,Department of Biochemistry and Microbiology
[2] Institute of Chemical Technology Prague,undefined
来源
Chemical Papers | 2015年 / 69卷
关键词
mercury detection assay; bioluminescent bioreporter; sea water; ARL1; whole-cell biosensor;
D O I
暂无
中图分类号
学科分类号
摘要
The present study demonstrates the influences of chlorides, fluorides and bromides of potassium and sodium on the growth and Hg2+-induced bioluminescence of bioreporter Escherichia coli ARL1. In a Luria-Bertani medium (LB), cell growth was inhibited by concentrations of sodium and potassium fluorides above 0.2 mol L−1. The addition of NaCl increased cell tolerance to the toxic effects of fluorides and bromides. Lag periods of 10 h and more were observed for cultivations in LB without NaCl and with halides (NaCl, KCl, NaBr, KBr, NaF and KF) at concentrations lower than 0.06 mol L−1. In a phosphate buffer (PB), the bioluminescence of E. coli ARL1, induced with HgCl2, was increased by the addition of NaCl, KCl, NaBr, KBr, NaF and KF (concentration of 0–0.25 mol L−1). In a saline phosphate buffer (PBS), the maxima of induced bioluminescence declined to 50 %, in the case of NaF (0.12 mol L−1), and to zero for KF. An addition of tryptone to the induction medium increased induced light emission ten-fold. Concentrated artificial sea water (ASW) (70–100 % ASW) inhibited bioluminescence induction. The new detection assay with E. coli ARL1 made possible the detection of 0.57 µL−1 of HgCl2 in double-diluted artificial sea water (25 % ASW).
引用
收藏
页码:183 / 191
页数:8
相关论文
共 50 条
  • [41] Electroactive bacteria as whole-cell biosensor for sensitive detection of hydrogen peroxide
    Wen, Junlin
    He, Daigui
    Zhuo, Tongye
    Li, Wanqing
    Liu, Jianbo
    Wu, Jialin
    Zhao, Yurong
    Yuan, Yong
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (02):
  • [42] Whole-cell biosensor for determination of volatile organic compounds in the form of aerosols
    Naessens, M
    Tran-Minh, A
    ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) : 153 - 158
  • [43] Whole-cell arsenite biosensor using photosynthetic bacterium Rhodovulum sulfidophilumRhodovulum sulfidophilum as an arsenite biosensor
    Hiroyuki Fujimoto
    Masato Wakabayashi
    Hidenori Yamashiro
    Isamu Maeda
    Katsuhiro Isoda
    Masuo Kondoh
    Masaya Kawase
    Hitoshi Miyasaka
    Kiyohito Yagi
    Applied Microbiology and Biotechnology, 2006, 73 : 332 - 338
  • [44] ENHANCEMENT OF OPERATIONAL STABILITY OF IMMOBILIZED WHOLE-CELL D-HYDANTOINASE
    KIM, DM
    KIM, GJ
    KIM, HS
    BIOTECHNOLOGY LETTERS, 1994, 16 (01) : 11 - 16
  • [45] A genetically encoded fluorescent whole-cell biosensor for real-time detecting estrogenic activities in water samples
    He, Ruonan
    Yang, Junyi
    Yuan, Shengjie
    Chen, Ling
    Ren, Hongqiang
    Wu, Bing
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 485
  • [46] Advances in bacterial whole-cell biosensors for the detection of bioavailable mercury: A review
    Chen, Yueqian
    Guo, Yingying
    Liu, Yanwei
    Xiang, Yuping
    Liu, Guangliang
    Zhang, Qinghua
    Yin, Yongguang
    Cai, Yong
    Jiang, Guibin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 868
  • [47] Guiding pancreatic beta cells to target electrodes in a whole-cell biosensor for diabetes
    Pedraza, Eileen
    Karajic, Aleksandar
    Raoux, Matthieu
    Perrier, Romain
    Pirog, Antoine
    Lebreton, Fanny
    Arbault, Stephane
    Gaitan, Julien
    Renaud, Sylvie
    Kuhn, Alexander
    Lang, Jochen
    LAB ON A CHIP, 2015, 15 (19) : 3880 - 3890
  • [48] A Whole-Cell Biosensor for Point-of-Care Detection of Waterborne Bacterial Pathogens
    Wu, Ying
    Wang, Chien-Wei
    Wang, Dong
    Wei, Na
    ACS SYNTHETIC BIOLOGY, 2021, 10 (02): : 333 - 344
  • [49] Whole-cell Gluconobacter oxydans biosensor for 2-phenylethanol biooxidation monitoring
    Schenkmayerova, Andrea
    Bertokova, Aniko
    Sefcovicova, Jana
    Stefuca, Vladimir
    Bucko, Marek
    Vikartovska, Alica
    Gemeiner, Peter
    Tkac, Jan
    Katrlik, Jaroslav
    ANALYTICA CHIMICA ACTA, 2015, 854 : 140 - 144
  • [50] Bacterial Whole-Cell Biosensor for Glutamine with Applications for Quantifying and Visualizing Glutamine in Plants
    Tessaro, Michael J.
    Soliman, Sameh S. M.
    Raizada, Manish N.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2012, 78 (02) : 604 - 606