Analysis of boron in biological reference materials using prompt gamma activation analysis

被引:0
|
作者
Hyun-Je Cho
Yong-Sam Chung
Young-Jin Kim
机构
[1] Korea Atomic Energy Research Institute,
[2] KAERI,undefined
[3] Korea Atomic Energy Research Institute,undefined
[4] KAERI,undefined
[5] Korea Atomic Energy Research Institute,undefined
[6] KAERI,undefined
关键词
Boron; Bran; Boron Concentration; Oyster Tissue; Apple Leave;
D O I
暂无
中图分类号
学科分类号
摘要
A prompt gamma activation analysis facility has been constructed on the ST1 horizontal beam port at the HANARO research reactor, KAERI in 2003. The detector system consists of a high-purity Ge detector surrounded by BGO/NaI(Tl) scintillators as an annulus type to reject the Compton scattered photons. Detection sensitivity for boron was obtained from the prompt gamma-ray spectra of boric acid, B(OH)3, containing 0.1-65 μg boron. The net peak for the calculation of the boron concentration was obtained by eliminating the sodium 472 keV peak, involved in the boron 478 keV peak. The biological samples used are NIST SRMs such as Peach Leaves, Apple Leaves, Tomato Leaves, Spinach Leaves, Total Diet, Typical Diet, Oyster Tissue and Corn Bran, etc. The measured values for high boron concentration showed up to a 3% of the relative, but in a low concentration below 5 ppm, present values were higher than the certified ones.
引用
收藏
页码:701 / 705
页数:4
相关论文
共 50 条
  • [31] Prompt gamma activation analysis using a chopped neutron beam
    Révay, Z
    Belgya, T
    Szentmiklósi, L
    Molnár, GL
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (02) : 277 - 281
  • [32] The use of prompt gamma activation analysis (PGAA) for the analyses and characterization of materials: Photochromic materials
    Perry, DL
    English, GA
    Firestone, RB
    Leung, KN
    Reijonen, J
    Ludewigt, B
    Garabedian, G
    Molnar, GL
    Revay, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 527 - 529
  • [33] PROMPT GAMMA-RAY NEUTRON-ACTIVATION ANALYSIS OF B-10 IN BIOLOGICAL-MATERIALS
    MATSUMOTO, T
    AIZAWA, O
    APPLIED RADIATION AND ISOTOPES, 1990, 41 (09) : 897 - 903
  • [34] Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source
    Ş. Turhan
    H. Yücel
    A. Demirbaş
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 262 (3) : 661 - 664
  • [35] Determination of boron over a large dynamic range by prompt-gamma activation analysis
    Harrison, R. K.
    Landsberger, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (03): : 513 - 518
  • [36] Prompt gamma activation analysis for boron determination in the tens of milligram range at the HOTNES facility
    Bedogni, R.
    Russo, L.
    Campoy, A. I. Castro
    Dashdondog, D.
    Caballero-Pacheco, M. A.
    Calamida, A.
    Pietropaolo, A.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (07):
  • [37] Development of boron calibration via hybrid comparator method in prompt gamma activation analysis
    Artnak, E. J.
    Biegalski, S. R.
    Landsberger, S.
    Ianno, N. J.
    Alexander, D.
    Byers, M. F.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (01) : 271 - 277
  • [38] Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source
    Ş. Turhan
    H. Yücel
    A. Demirbaş
    Journal of Radioanalytical and Nuclear Chemistry, 2004, 262 : 661 - 667
  • [39] Development of boron calibration via hybrid comparator method in prompt gamma activation analysis
    E. J. Artnak
    S. R. Biegalski
    S. Landsberger
    N. J. Ianno
    D. Alexander
    M. F. Byers
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 318 : 271 - 277
  • [40] Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source
    Turhan, S
    Yücel, H
    Demirbas, A
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 262 (03) : 661 - 664