Prediction of formic acid chromatogram in gradient elution chromatography

被引:0
|
作者
Won H.-J. [1 ]
Kim I.-H. [1 ]
机构
[1] Department of Chemical Engineering, Chungnam National University
关键词
Distribution coefficient; Gradient elution chromatography; Organic acid; Simulation;
D O I
10.1007/BF02942247
中图分类号
学科分类号
摘要
Optimal operation in chromatography is needed to save operation time and the solvent used in multiple chromatographic runs. To this end, many simulation studies of chromatography process have been performed. The relationship between the distribution coefficient and the ionic strength is important in gradient elution ion chromatography. Experimental runs and computer simulations were carried out under linear gradient elution conditions in order to compare the experiments and the simulation. Experiments were performed with formic acid under isocratic conditions to determine the simulation equation parameters. Computer simulation was based on three equations which related distribution with ionic strength as follows; K=αI-β, K=A+BI+CI2 and K=y0+A1 · e(-I/m1)+A2 · e(-I/m2). The effects of gradient slope on the chromatograms are discussed, and good agreement between the experimental and the simulated results is shown.
引用
收藏
页码:31 / 36
页数:5
相关论文
共 50 条
  • [31] Hydrophilic interaction ultra performance liquid chromatography retention prediction under gradient elution
    Gika, Helen
    Theodoridis, Georgios
    Mattivi, Fulvio
    Vrhovsek, Urska
    Pappa-Louisi, Adriani
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (03) : 701 - 709
  • [32] EFFECT OF MODULATOR SORPTION IN GRADIENT ELUTION CHROMATOGRAPHY - GRADIENT DEFORMATION
    VELAYUDHAN, A
    LADISCH, MR
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (01) : 233 - 239
  • [33] CALCULATION OF ELUTION PEAK POSITIONS IN GRADIENT ELUTION CHROMATOGRAPHY WITH AN ION EXCHANGER
    OHASHI, S
    KOGUCHI, K
    JOURNAL OF CHROMATOGRAPHY, 1967, 27 (01): : 214 - &
  • [34] Rate parameters and gradient correlations for gradient-elution chromatography
    Luo, RG
    Hsu, JT
    AICHE JOURNAL, 1997, 43 (02) : 464 - 474
  • [35] Stability of formic acid in methanol solutions and the implications for use in LC-MS gradient elution analysis
    Snoble, Karel A. J.
    Fox, Neal M.
    Lorenz, Sandra M.
    Kemperman, Anthony R.
    Przybytek, J. T.
    LC GC NORTH AMERICA, 2008, 26 (09) : 946 - 950
  • [36] HPLC Separation of Carboxylic Acids Using Porous Graphitized Carbon and Gradient Elution with Formic Acid Solutions
    K. S. Gutenev
    M. A. Statkus
    G. I. Tsizin
    Journal of Analytical Chemistry, 2022, 77 : 1287 - 1293
  • [37] LINEAR ELUTION ADSORPTION CHROMATOGRAPHY .7. GRADIENT ELUTION THEORY
    SYNDER, LR
    JOURNAL OF CHROMATOGRAPHY, 1964, 13 (02): : 415 - &
  • [38] Optimization in preparative gradient elution chromatography.
    Velayudhan, A
    Ramanan, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U270 - U270
  • [39] HPLC Separation of Carboxylic Acids Using Porous Graphitized Carbon and Gradient Elution with Formic Acid Solutions
    Gutenev, K. S.
    Statkus, M. A.
    Tsizin, G., I
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (10) : 1287 - 1293
  • [40] Migration and elution equations in gradient liquid chromatography
    Blumberg, Leonid M.
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1599 : 35 - 45