Numerical simulation of pulsatile blood flow through asymmetric arterial stenoses under EECP

被引:0
|
作者
Du J.-H. [1 ]
Wu C.-L. [1 ]
Zheng Z.-S. [2 ]
Dai G. [2 ]
机构
[1] Department of Engineering, Guangdong Ocean university, Zhanjiang
[2] Key Lab. On Assisted Circulation, Ministry of Health, Guangzhou
关键词
hemodynamics EECP (enhanced external counterpulsation) arterial stenosis;
D O I
10.1007/BF03400454
中图分类号
学科分类号
摘要
In this paper, a three-dimensional model of pulsatile blood flow througth a vessel with an asymmetric stenosis is developed to numerically study the hemodynamics circumstance under EECP (Enhanced External Counter Pulsation). The governing equations are the usual Navier-Stokes equations for unsteady elliptic flows, and are numerically solved by using finite volume method. The numerical computing is based on the animal experiment. The blood flow rate curves in a cadiac cycle pre-EECP and post-EECP are detected in a pig’s carotid respectively, the counterpulsation pressure is 0.03MPa. The blood flow rate curves are transformed to blood velocity distributions along the arterial diameter by using the Womersley arithmetic. And the Womersley velocity profiles are used as inflow boundary conditions to simulate the whole hemodynamics circumstance inside the 3-dimensional artery model. The computational results show that when EECP is applied, the blood flow rate and the wall shear stress level of the artery are increased in a cadiac cycle, as well as the pulsatile character of blood flow and wall shear stress. Which are possibly the hemodynamic actors that lead to the improving of the endothelial function which is thought to be straightly relating to the atherosclerosis. © 2006, China Ship Scientific Research Center.
引用
收藏
页码:246 / 251
页数:5
相关论文
共 50 条
  • [21] Numerical simulation of red blood cell aggregation under pulsatile flow with depletion model
    Li, Ying
    Bok, Tae-Hoon
    Paeng, Dong-Guk
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 442 - 445
  • [22] Numerical simulation of pulsatile blood flow through eccentric double stenosed carotid artery
    Rajmane, Swapnil Narayan
    Tiwari, Shaligram
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2024, 34 (03) : 1323 - 1350
  • [23] Numerical simulation of spatiotemporal red blood cell aggregation under sinusoidal pulsatile flow
    Lee, Cheong-Ah
    Paeng, Dong-Guk
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] Numerical simulation of spatiotemporal red blood cell aggregation under sinusoidal pulsatile flow
    Cheong-Ah Lee
    Dong-Guk Paeng
    Scientific Reports, 11
  • [25] Numerical analysis of pulsatile blood flow and vessel wall mechanics in different degrees of stenoses
    Li, M. X.
    Beech-Brandt, J. J.
    John, L. R.
    Hoskins, P. R.
    Easson, W. J.
    JOURNAL OF BIOMECHANICS, 2007, 40 (16) : 3715 - 3724
  • [26] SIMULATION OF PULSATILE BLOOD FLOW THROUGH A FLEXIBLE CANNULA
    Corbett, Scott C.
    Coskun, Ahmet U.
    N-Hashemi, Hamid
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 245 - 246
  • [27] EFFECT OF ARTERIAL DISTENSIBILITY AND STENOSES ON PRESSURE DROP IN PULSATILE FLOW
    Rotman, Oren
    Zaretsky, Uri
    Shitzer, Avraham
    Einav, Shmuel
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 587 - 588
  • [28] PULSATILE BLOOD-FLOW IN AN ARTERIAL BIFURCATION - NUMERICAL-SOLUTION
    EINAV, S
    STOLERO, D
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (01) : 12 - 17
  • [29] Numerical simulation of pulsatile flow through a compliant stenotic tube
    Li, M
    Beech-Brandt, JJ
    Easson, WJ
    Hoskins, PR
    PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 157 - 162
  • [30] Numerical investigation of physiologically realistic pulsatile flow through arterial stenosis
    Long, Q
    Xu, XY
    Ramnarine, KV
    Hoskins, P
    JOURNAL OF BIOMECHANICS, 2001, 34 (10) : 1229 - 1242