摘要
The results of experimental studies of thermal conductivity of the dominant types of external contaminants of air coolers are given. Reed down, peat litter, leaves, sand, pine needles, and ash were investigated, as well as mixtures: sand with ash, sand with reed down, peat litter with leaves. The results are presented as the dependence of thermal conductivity on the density of contaminants. A linear approximation generalizing the found dependences is recommended. It is shown that thermal conductivity is significantly dependent on the pollutant porosity. © 2017, Springer Science+Business Media, LLC.
引用
收藏
页码:244 / 247
页数:3
相关论文
共 50 条
  • [41] AIR-COOLED EXCHANGERS IN COLD CLIMATES
    SHIPES, KV
    CHEMICAL ENGINEERING PROGRESS, 1974, 70 (07) : 53 - 58
  • [42] Thermal performance reduction in air-cooled heat exchangers due to nonuniform flow and temperature distributions
    Beiler, MG
    Kroger, DG
    HEAT TRANSFER ENGINEERING, 1996, 17 (01) : 82 - 92
  • [43] EFFECT OF TUBE BANK INCLINATION ON THE THERMAL HYDRAULIC PERFORMANCE OF AIR-COOLED HEAT EXCHANGERS.
    Monheit, Max
    Freim, James
    Heat Transfer Engineering, 1987, 8 (01) : 19 - 24
  • [44] Shape optimisation of air-cooled finned-tube heat exchangers
    Nemati, H.
    Moghimi, M. A.
    Sapin, P.
    Markides, C. N.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 150
  • [45] The influence of wind on the performance of forced draught air-cooled heat exchangers
    Duvenhage, K
    Kroger, DG
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 62 (2-3) : 259 - 277
  • [46] USE OF INDUSTRIAL EXPERIENCES IN CONSTRUCTING AIR-COOLED HEAT-EXCHANGERS
    BARATOSSY, J
    GANOCZY, J
    CHEMISCHE TECHNIK, 1976, 28 (06): : 380 - 380
  • [47] Constructal design of finned tubes used in air-cooled heat exchangers
    Hossein Shokouhmand
    Shoeib Mahjoub
    Mohammad Reza Salimpour
    Journal of Mechanical Science and Technology, 2014, 28 : 2385 - 2391
  • [48] ELIMINATING HEIGHT AND WIND EFFECTS ON AIR-COOLED HEAT-EXCHANGERS
    STUHLBARG, D
    SZURGOT, AM
    CHEMICAL ENGINEERING, 1987, 94 (17) : 151 - 154
  • [49] SIMULATION OF AIR-COOLED HEAT-EXCHANGERS IN THE CHEMICAL-INDUSTRY
    WUNDERLICH, D
    CHEMISCHE TECHNIK, 1981, 33 (09): : 496 - 496
  • [50] OPERATION OF AIR-COOLED HEAT-EXCHANGERS IN CHEMICAL-INDUSTRY
    KUNZE, R
    NOACK, J
    STUBNER, F
    CHEMISCHE TECHNIK, 1976, 28 (11): : 659 - 661