Simulation of convective heat removal in a stratified tank of the integrated collector storage solar water heater with builtin heat exchanger

被引:1
|
作者
Oshchepkov M.Y. [1 ]
Frid S.E. [2 ]
机构
[1] OOO Politermo, Moscow oblast
[2] Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow
关键词
Heat Transfer Coefficient; Heat Exchanger; Heat Removal; Apply Solar Energy; Serial Connection;
D O I
10.3103/S0003701X16010084
中图分类号
学科分类号
摘要
Free convective heat removal in a stratified inclined storage tank with builtin heat exchanger is numerically simulated. The effects of coolant flow rate and tank installation angle on heat transfer are investigated. The possibility of the integration of several of tanks into the battery is analyzed. If there are not many tanks, their serial connection in the battery is more preferable than parallel because of the significant output gain. © 2016, Allerton Press, Inc.
引用
收藏
页码:40 / 46
页数:6
相关论文
共 50 条
  • [41] THE EFFECT OF PITCH ON HEAT TRANSFER TO AN IMMERSED HEAT EXCHANGER IN A SOLAR THERMAL STORAGE TANK WITH AND WITHOUT A BAFFLE
    Nicodemus, Julia Haltiwanger
    Smith, Joshua
    Holme, Alexander
    Johnson, Sarah
    Petitt, Kyle
    PROCEEDINGS OF ASME 2022 16TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, ES2022, 2022,
  • [42] The Effect of Pitch on Heat Transfer to an Immersed Heat Exchanger in a Solar Thermal Storage Tank With and Without a Baffle
    Nicodemus, Julia Haltiwanger
    Smith, Joshua
    Holme, Alexander
    Johnson, Sarah
    Petitt, Kyle
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (06):
  • [43] TRANSIENT ANALYSIS OF A NATURAL CIRCULATION SOLAR WATER HEATER WITH A HEAT-EXCHANGER
    SODHA, MS
    SHUKLA, SN
    TIWARI, GN
    JOURNAL OF ENERGY, 1983, 7 (02): : 107 - 111
  • [44] Experimental study on an integrated collector storage solar air heater based on flat micro-heat pipe arrays
    Wang, Z. Y.
    Diao, Y. H.
    Liang, L.
    Zhao, Y. H.
    Zhu, T. T.
    Bai, F. W.
    ENERGY AND BUILDINGS, 2017, 152 : 615 - 628
  • [45] EFFECT OF HEAT-EXCHANGER ON THE PERFORMANCE OF A SHALLOW SOLAR POND WATER HEATER
    BANSAL, PK
    HRISHIKESAN, DS
    GARG, HP
    ENERGY CONVERSION AND MANAGEMENT, 1984, 24 (04) : 259 - 263
  • [46] Numerical analysis of charging and discharging performance of an integrated collector storage solar water heater
    Hamed, Mouna
    Fallah, Ali
    Ben Brahim, Ammar
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (13) : 8777 - 8789
  • [47] Integrated collector storage solar water heater with compound parabolic concentrator - development and progress
    Devanarayanan, K.
    Murugavel, K. Kalidasa
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 39 : 51 - 64
  • [48] Performance simulation of multiple heat source solar heat pump water heater system
    Yang, Lei
    Zhang, Xiaosong
    Huagong Xuebao/CIESC Journal, 2009, 60 (09): : 2292 - 2298
  • [49] Numerical and empirical evaluation of a novel building integrated collector storage solar water heater
    Garnier, Celine
    Muneer, Tariq
    Currie, John
    RENEWABLE ENERGY, 2018, 126 : 281 - 295
  • [50] Thermal performance of integrated collector storage solar water heater with corrugated absorber surface
    Kumar, Rakesh
    Rosen, Marc A.
    APPLIED THERMAL ENGINEERING, 2010, 30 (13) : 1764 - 1768