How to achieve accurate blood culture volumes: the BD BACTEC FX blood volume monitoring system as a measuring instrument and educational tool

被引:0
|
作者
L. Cattoir
J. Claessens
R. Cartuyvels
A. M. Van den Abeele
机构
[1] Saint Lucas Hospital,Department of Clinical Microbiology
[2] Jessa Hospital,Department of Clinical Microbiology
关键词
Blood culture; Blood volume; Continuous quality improvement; Becton Dickinson; Blood volume monitoring system;
D O I
暂无
中图分类号
学科分类号
摘要
Collecting adequate volumes of blood in blood culture bottles is crucial for sensitive detection of bacteremia and fungemia. Tools enabling easy collection of data on the degree of blood culture bottle filling at different hospital departments are an important step toward quality measurement and improvement. In this study, we verified the accuracy of a software tool for the monitoring of blood culture bottle filling developed by Becton Dickinson, BD blood volume monitoring system (BVMS) that was adjusted for use on plastic BACTEC bottles, and evaluated its ease of use in routine practice. In total, 538 negative plastic BD BACTEC Plus Aerobic/F blood culture bottles collected in two secondary care hospitals in Belgium were included in the study. The BVMS software demonstrated good performance, with an acceptable mean difference of − 0.3 mL or − 4.0% between the mean volume estimated by BVMS and the mean weight-based volume. Data (mean blood volume and standard deviation) and figures (box-and-whisker and histogram plots) on blood culture bottle filling are easily acquired. They provide information on the current situation in a hospital (department) and can be used as a tool for quality improvement measurements and follow-up. Caution is required when interpreting BVMS results for hospital wards where a substantial amount of the bottles collected come from patients with hematocrit values < 30%. This study demonstrated that BVMS is a reliable and easy to use tool which facilitates monitoring and coordination of optimization of blood culture bottles filling by the clinical laboratory.
引用
收藏
页码:1621 / 1626
页数:5
相关论文
共 25 条
  • [21] Active Monitoring and Feedback to Improve Blood Culture Fill Volumes and Positivity Across a Large Integrated Health System
    Khare, Reeti
    Kothari, Tarush
    Castagnaro, Joseph
    Hemmings, Bryan
    Tso, May
    Juretschko, Stefan
    CLINICAL INFECTIOUS DISEASES, 2020, 70 (02) : 262 - 268
  • [22] MULTICENTER CLINICAL-EVALUATION OF A CONTINUOUS MONITORING BLOOD CULTURE SYSTEM USING FLUORESCENT-SENSOR TECHNOLOGY (BACTEC-9240)
    NOLTE, FS
    WILLIAMS, JM
    JERRIS, RC
    MORELLO, JA
    LEITCH, CD
    MATUSHEK, S
    SCHWABE, LD
    DORIGAN, F
    KOCKA, FE
    JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (03) : 552 - 557
  • [23] Rapid and accurate direct antibiotic susceptibility testing of blood culture broths using MALDI Sepsityper combined with the BD Phoenix automated system
    Hazelton, Briony
    Thomas, Lee C.
    Olma, Thomas
    Kok, Jen
    O'Sullivan, Matthew
    Chen, Sharon C. -A.
    Iredell, Jonathan R.
    JOURNAL OF MEDICAL MICROBIOLOGY, 2014, 63 : 1590 - 1594
  • [24] Early identification of microorganisms in blood culture prior to the detection of a positive signal in the BACTEC FX system using matrix-assisted laser desorption/ionization-time of flight mass spectrometry
    Wang, Ming-Cheng
    Lin, Wei-Hung
    Yan, Jing-Jou
    Fang, Hsin-Yi
    Kuo, Te-Hui
    Tseng, Chin-Chung
    Wu, Jiunn-Jong
    JOURNAL OF MICROBIOLOGY IMMUNOLOGY AND INFECTION, 2015, 48 (04) : 419 - 424
  • [25] Bacteremia after endoscopic retrograde cholagiopancreatography: A prospective study using a high-blood volume continuous monitoring culture system.
    Campos, GMR
    Herani, B
    Pereira, CAP
    Machado, AMO
    Baretta, MCC
    GASTROINTESTINAL ENDOSCOPY, 1998, 47 (04) : AB110 - AB110