How to achieve accurate blood culture volumes: the BD BACTEC FX blood volume monitoring system as a measuring instrument and educational tool

被引:0
|
作者
L. Cattoir
J. Claessens
R. Cartuyvels
A. M. Van den Abeele
机构
[1] Saint Lucas Hospital,Department of Clinical Microbiology
[2] Jessa Hospital,Department of Clinical Microbiology
关键词
Blood culture; Blood volume; Continuous quality improvement; Becton Dickinson; Blood volume monitoring system;
D O I
暂无
中图分类号
学科分类号
摘要
Collecting adequate volumes of blood in blood culture bottles is crucial for sensitive detection of bacteremia and fungemia. Tools enabling easy collection of data on the degree of blood culture bottle filling at different hospital departments are an important step toward quality measurement and improvement. In this study, we verified the accuracy of a software tool for the monitoring of blood culture bottle filling developed by Becton Dickinson, BD blood volume monitoring system (BVMS) that was adjusted for use on plastic BACTEC bottles, and evaluated its ease of use in routine practice. In total, 538 negative plastic BD BACTEC Plus Aerobic/F blood culture bottles collected in two secondary care hospitals in Belgium were included in the study. The BVMS software demonstrated good performance, with an acceptable mean difference of − 0.3 mL or − 4.0% between the mean volume estimated by BVMS and the mean weight-based volume. Data (mean blood volume and standard deviation) and figures (box-and-whisker and histogram plots) on blood culture bottle filling are easily acquired. They provide information on the current situation in a hospital (department) and can be used as a tool for quality improvement measurements and follow-up. Caution is required when interpreting BVMS results for hospital wards where a substantial amount of the bottles collected come from patients with hematocrit values < 30%. This study demonstrated that BVMS is a reliable and easy to use tool which facilitates monitoring and coordination of optimization of blood culture bottles filling by the clinical laboratory.
引用
收藏
页码:1621 / 1626
页数:5
相关论文
共 25 条
  • [1] How to achieve accurate blood culture volumes: the BD BACTEC FX blood volume monitoring system as a measuring instrument and educational tool
    Cattoir, L.
    Claessens, J.
    Cartuyvels, R.
    Van den Abeele, A. M.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2018, 37 (09) : 1621 - 1626
  • [2] Impact of monitoring blood volume in the BD BACTEC™ FX blood culture system: virtual volume versus actual volume
    Chang, Jeonghyun
    Park, Jeong Su
    Park, Sookja
    Choi, Byeonghoo
    Yoon, Nam Seop
    Sung, Heungsup
    Kim, Mi-Na
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 81 (02) : 89 - 93
  • [3] Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure
    Coorevits, L.
    Van den Abeele, A. -M.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2015, 34 (07) : 1459 - 1466
  • [4] Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure
    L. Coorevits
    A.-M. Van den Abeele
    European Journal of Clinical Microbiology & Infectious Diseases, 2015, 34 : 1459 - 1466
  • [5] Validity of reducing blood culture incubation time for the BD BACTEC FX blood culture system considering microbiological and clinical aspects
    Hashimoto, Takehiro
    Yahiro, Takaaki
    Khan, Sakirul
    Kimitsuki, Kazunori
    Nishizono, Akira
    Hiramatsu, Kazufumi
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2025, 31 (01)
  • [6] VALUE COMPARISON OF BACT/ALERT®; VIRTUO® SYSTEM VERSUS BD BACTEC™ FX BLOOD CULTURE SYSTEM FROM A PROVIDER PERSPECTIVE
    Krishnamurthy, P.
    Anaya, P.
    Bilir, S. P.
    Smith, Jurcic K.
    Suchanek, A.
    MacVane, S.
    VALUE IN HEALTH, 2024, 27 (06) : S75 - S75
  • [7] Clinical Significance of BD Bactec FX Blood Culture Incubation Beyond 96 Hours (4 Days)
    Ulrich, Patrizia Sophia
    Bastian, Ingmar N.
    Chen, Derrick J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2022, 60 (07)
  • [8] SPECIMEN VOLUME VERSUS YIELD IN THE BACTEC BLOOD CULTURE SYSTEM
    PLORDE, JJ
    TENOVER, FC
    CARLSON, LG
    JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (02) : 292 - 295
  • [9] The BD BACTEC FX blood culture system with the gentlemacs dissociator is suitable for sterility testing of heart valve and vascular allografts—A validation study
    Ramadan Jashari
    Sarah Vanzeebroeck
    Pieter Petit
    Hector Rodriguez-Villalobos
    Sharon Zahra
    Naziha Ben Said
    Vanessa Bouzet
    Stefano Mastrobuoni
    Cell and Tissue Banking, 2021, 22 : 453 - 466
  • [10] The BD BACTEC FX blood culture system with the gentlemacs dissociator is suitable for sterility testing of heart valve and vascular allografts-A validation study
    Jashari, Ramadan
    Vanzeebroeck, Sarah
    Petit, Pieter
    Rodriguez-Villalobos, Hector
    Zahra, Sharon
    Ben Said, Naziha
    Bouzet, Vanessa
    Mastrobuoni, Stefano
    CELL AND TISSUE BANKING, 2021, 22 (03) : 453 - 466