Quality of adverse drug reaction (QADRA) reports: An algorithm to appraise the efficiency of spontaneous reporting systems in pharmacovigilance

被引:4
|
作者
Tuccori M. [1 ,7 ]
Giustarini G. [2 ]
Blandizzi C. [2 ]
Capogrosso-Sansone A. [2 ]
Rossi M. [3 ]
Gori G. [4 ]
Scarpini F. [5 ]
Mantarro S. [2 ]
Montagnani S. [2 ]
Vannacci A. [6 ]
Antonioli L. [2 ]
Fornai M. [2 ]
Lapi F. [6 ]
机构
[1] Adverse Drug Reaction Monitoring Unit, University Hospital of Pisa, Pisa
[2] Interdepartmental Centre for Research in Clinical Pharmacology and Experimental Therapeutics, University of Pisa, Pisa
[3] Department of Pharmacology, University of Siena, Siena
[4] Centre of Clinical Pharmacology for Drug Experimentation, University Hospital of Pisa, Pisa
[5] Department of Internal Medicine, University Hospital of Siena, Siena
[6] Department of Pharmacology, Center for Molecular Medicine (CIMMBA), University of Florence, Florence
[7] Tuscan Regional Centre for Pharmacovigilance, Adverse Drug Reaction Monitoring Unit, University Hospital of Pisa, Via Roma 55
关键词
Adverse drug reaction; Algorithm; Pharmacovigilance; QADRA; Quality; Spontaneous reporting system;
D O I
10.1007/s10389-013-0562-y
中图分类号
学科分类号
摘要
Aim: To design and validate an algorithm for the multidimensional evaluation of the quality of adverse drug reaction (ADR) case reports (QADRA). Subject and methods: One hundred fifty-three patients randomly and retrospectively selected from 15,906 records included in the Italian database of spontaneous ADR reports throughout 2009. Each report was evaluated by two panels of experts blinded to one another as well as by the algorithm developed in the present study. Each case was classified taking three parameters into consideration: plausibility, notoriety and clinical relevance. Results: The two panels assessed that 21.6 % of reports were of "high" quality. When applying the QADRA algorithm (score range 0-15), its median value was 6 (4-7, 25 and 75 percentiles, respectively). The area under the receiver operator characteristics (ROC) curve, which assesses the ability of the risk score to predict the report quality, was 0.93 (95 % CI: 0.88-0.97). Herein, the cut-off points ≤5, 6 or 7 and ≥8 indicated the best balance between sensitivity and specificity, and they could be used to categorize the reports as being of 'high', 'intermediate' and 'low' quality (AUC = 0.87; 95 % CI: 0.80-0.92), respectively. Conclusion: The QADRA algorithm performs as a reliable and complete tool for assessing the quality of ADR reports. Several potential applications of this algorithm should be investigated in the future, both for scientific purposes and healthcare system management. © 2013 Springer-Verlag Berlin Heidelberg.
引用
收藏
页码:365 / 372
页数:7
相关论文
共 50 条
  • [31] Adverse drug reaction reporting: how can drug consumption information add to analyses using spontaneous reports?
    Svendsen, Kristian
    Halvorsen, Kjell H.
    Vorren, Solveig
    Samdal, Hilde
    Garcia, Beate
    [J]. EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2018, 74 (04) : 497 - 504
  • [32] Completeness of Spontaneous Adverse Drug Reaction Reports Sent by General Practitioners to a Regional Pharmacovigilance Centre: A Descriptive Study
    Durrieu, Genevieve
    Jacquot, Julien
    Mege, Mathilde
    Bondon-Guitton, Emmanuelle
    Rousseau, Vanessa
    Montastruc, Francois
    Montastruc, Jean-Louis
    [J]. DRUG SAFETY, 2016, 39 (12) : 1189 - 1195
  • [33] Completeness of Spontaneous Adverse Drug Reaction Reports Sent by General Practitioners to a Regional Pharmacovigilance Centre: A Descriptive Study
    Geneviève Durrieu
    Julien Jacquot
    Mathilde Mège
    Emmanuelle Bondon-Guitton
    Vanessa Rousseau
    François Montastruc
    Jean-Louis Montastruc
    [J]. Drug Safety, 2016, 39 : 1189 - 1195
  • [34] Adverse drug reactions - problems with spontaneous reporting systems
    Balidemaj, F.
    [J]. EUROPEAN JOURNAL OF PUBLIC HEALTH, 2017, 27
  • [35] Turkish physicians' pharmacovigilance and adverse drug reaction reporting knowledge, attitude, and practices
    Guner, M. D.
    Ekmekci, P. E.
    Ozis, S. E.
    [J]. DRUG SAFETY, 2017, 40 (10) : 951 - 951
  • [36] Ototoxic Adverse Drug Reactions: A Pharmacovigilance Study Using the Italian Spontaneous Reporting Database
    Barbieri, M. A.
    Cicala, G.
    Cutroneo, P. M.
    Mocciaro, E.
    Sottosanti, L.
    Freni, F.
    Galletti, F.
    Arcoraci, V.
    Spina, E.
    [J]. DRUG SAFETY, 2018, 41 (11) : 1162 - 1163
  • [37] Patterns of adverse drug reaction reporting in Ethiopia: A database analysis of spontaneous reports from 2013 to 2018
    Anebo, Zelalem Gebretsadik
    Abacioglu, Nurrettin
    [J]. ASIAN PACIFIC JOURNAL OF TROPICAL MEDICINE, 2022, 15 (02) : 56 - 62
  • [38] Patterns of adverse drug reaction reporting in Ethiopia: A database analysis of spontaneous reports from 2013 to 2018
    Zelalem Gebretsadik Anebo
    Nurrettin Abacioglu
    [J]. Asian Pacific Journal of Tropical Medicine, 2022, (02) : 56 - 62
  • [39] Use of proportional reporting ratios (PRRs) for signal generation from spontaneous adverse drug reaction reports
    Evans, SJW
    Waller, PC
    Davis, S
    [J]. PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2001, 10 (06) : 483 - 486
  • [40] Spontaneous Adverse Drug Reaction Reporting in Rural Districts of Mozambique
    Esperança Sevene
    Alda Mariano
    Ushma Mehta
    Maria Machai
    Alexander Dodoo
    David Vilardell
    Sam Patel
    Karen Barnes
    Xavier Carné
    [J]. Drug Safety, 2008, 31 : 867 - 876