Calibration method for microscale stereo X-ray imaging system

被引:0
|
作者
Youngjun Kim
Wontae Kim
Sehyung Park
Jong-Hyeong Kim
机构
[1] Korea Institute of Science and Technology,Bionics Research Group
[2] K & I Technology Co.,Institute for Industrial Technology Policy
[3] Seoul National University of Science & Technology,undefined
关键词
Calibration; Dual X-ray; Micro-scale X-ray; Radiographic imaging; Stereo X-ray;
D O I
暂无
中图分类号
学科分类号
摘要
Calibration of an X-ray imaging system involves estimation of the 3D geometrical configuration of the system components. Here, we propose a calibration method for stereo X-ray imaging systems, which capture two X-ray images at two orthogonal positions. The calibration parameters include the relation between image coordinates and world coordinates, the relative 3D positions of the X-ray source and detector, and the rotational axis of the stereo X-ray system. The average error of the proposed calibration method was determined to be approximately 0.03% in evaluation tests.
引用
收藏
页码:877 / 882
页数:5
相关论文
共 50 条
  • [21] Calibration of a soft X-ray projection system
    Schmitt, Robert
    Damm, Bioem
    Volk, Raimund
    TWO- AND THREE-DIMENSIONAL METHODS FOR INSPECTION AND METROLOGY VI, 2008, 7066
  • [22] Optimal calibration of an X-ray detection system
    Spindler, Karlheinz
    PROCEEDINGS OF THE 11TH WSEAS INTERNATIONAL CONFERENCE ON SYSTEMS, VOL 2: SYSTEMS THEORY AND APPLICATIONS, 2007, : 229 - +
  • [23] Polarization properties of X-ray tubes used for Imaging X-ray Polarimetry Explorer calibration
    Ratheesh, Ajay
    Rankin, John
    Costa, Enrico
    Del Monte, Ettore
    Di Marco, Alessandro
    Fabiani, Sergio
    La Monaca, Fabio
    Muleri, Fabio
    Rubini, Alda
    Soffitta, Paolo
    Baldini, Luca
    Minuti, Massimo
    Pinchera, Michele
    Sgro, Carmelo
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2023, 9 (03)
  • [24] X-ray fluorescence and X-ray transmission microtomography imaging system
    Pereira, Gabriela R.
    Rocha, Henrique S.
    Anjos, Marcelino J.
    Faria, Paulo
    Perez, Carlos A.
    Lopes, Ricardo T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 128 - 132
  • [25] Stereo X-Ray Tomography
    Shang, Zhenduo
    Blumensath, Thomas
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (07) : 1436 - 1443
  • [26] DEVICE FOR ABSOLUTE CALIBRATION OF X-RAY-IMAGING DETECTORS AND X-RAY COUNTERS
    KOLESNIKOV, KA
    LYSENKO, AP
    MEDVEDKO, AS
    PANCHENKO, VE
    ZAGORODNIKOV, EI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2336 - 2336
  • [27] Calibration analysis of a stereo imaging system
    Wei, H
    Thomas, AL
    ISMTII'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS, 2001, : 277 - 284
  • [28] Calibration of X-Ray diffractometer by the experimental comparison method
    A. P. Dudka
    Crystallography Reports, 2015, 60 : 601 - 609
  • [29] Calibration of X-Ray Diffractometer by the Experimental Comparison Method
    Dudka, A. P.
    CRYSTALLOGRAPHY REPORTS, 2015, 60 (04) : 601 - 609
  • [30] X-ray imaging spectrometers for Astro-E: Ground calibration in soft X-ray range
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Tsunemi, H
    Yoshita, E
    Kohmura, T
    Mori, K
    Katayama, K
    Katayama, H
    Shouho, M
    Ohta, M
    Dotani, T
    Ozaki, M
    Koyama, K
    Awaki, H
    Tsuru, TG
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 123 - 136