Calibration method for microscale stereo X-ray imaging system

被引:0
|
作者
Youngjun Kim
Wontae Kim
Sehyung Park
Jong-Hyeong Kim
机构
[1] Korea Institute of Science and Technology,Bionics Research Group
[2] K & I Technology Co.,Institute for Industrial Technology Policy
[3] Seoul National University of Science & Technology,undefined
关键词
Calibration; Dual X-ray; Micro-scale X-ray; Radiographic imaging; Stereo X-ray;
D O I
暂无
中图分类号
学科分类号
摘要
Calibration of an X-ray imaging system involves estimation of the 3D geometrical configuration of the system components. Here, we propose a calibration method for stereo X-ray imaging systems, which capture two X-ray images at two orthogonal positions. The calibration parameters include the relation between image coordinates and world coordinates, the relative 3D positions of the X-ray source and detector, and the rotational axis of the stereo X-ray system. The average error of the proposed calibration method was determined to be approximately 0.03% in evaluation tests.
引用
收藏
页码:877 / 882
页数:5
相关论文
共 50 条
  • [1] Calibration method for microscale stereo X-ray imaging system
    Kim, Youngjun
    Kim, Wontae
    Park, Sehyung
    Kim, Jong-Hyeong
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2012, 13 (06) : 877 - 882
  • [2] A calibration technique for monoplane stereo X-ray system in imaging guidance
    Jiang, HY
    Liu, H
    Chen, WR
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS II, 2000, 3911 : 122 - 129
  • [3] Imaging model for X-ray system and its calibration method
    Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
    不详
    Hanjie Xuebao, 2007, 7 (25-28):
  • [4] A Calibration Method for Conformal X-ray Transmission Imaging System
    Li, Yang
    Mou, Xuanqin
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [5] Calibration of a combined X-ray and laser imaging system
    Jin, Fenghua
    Jing, Hansong
    Qin, Lei
    Chen, Xin
    Tao, Yang
    OPTICS FOR NATURAL RESOURCES, AGRICULTURE, AND FOODS, 2006, 6381
  • [6] Calibration of x-ray fluorescence thyroid imaging system
    Mardirossian, G
    Matsushita, T
    Lei, K
    Clune, T
    Luo, D
    Karellas, A
    Botz, E
    Brill, AB
    PHYSICA MEDICA, 1996, 12 (02) : 83 - 92
  • [7] Method for calibration of a spectrozonal X-ray diagnostic system
    Lelyukhin A.S.
    Kornev E.A.
    Adzhieva M.D.
    Biomedical Engineering, 2006, 40 (5) : 241 - 242
  • [8] CALIBRATION OF A STEREO X-RAY DEVICE FOR USE IN BIOSTEREOMETRICS
    CURRY, S
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1984, 50 (03): : 361 - 363
  • [9] Computed stereo lensless X-ray imaging
    J. Duarte
    R. Cassin
    J. Huijts
    B. Iwan
    F. Fortuna
    L. Delbecq
    H. Chapman
    M. Fajardo
    M. Kovacev
    W. Boutu
    H. Merdji
    Nature Photonics, 2019, 13 : 449 - 453
  • [10] Computed stereo lensless X-ray imaging
    Duarte, J.
    Cassin, R.
    Huijts, J.
    Iwan, B.
    Fortuna, F.
    Delbecq, L.
    Chapman, H.
    Fajardo, M.
    Kovacev, M.
    Boutu, W.
    Merdji, H.
    NATURE PHOTONICS, 2019, 13 (07) : 449 - +