A number of factors influencing the measurement errors of analytic signals detected with secondary electron multipliers (SEMs) and registered with fast ADCs are analyzed. Such signals are generated in laser time-of-flight mass spectrometry at the stage of ion detection and recording of mass spectra. In particular, the effect of statistical factors and sources of systematic errors during both measurements of isotope ratios and elemental analysis is considered. Such errors as the statistics of formation of ion clots, the limited range of ADC records, discrimination during detection of ions of different masses, and others are considered. It is shown that, without taking into account the features of operation of SEMs and ADCs, both the statistical and systematic errors of measuring isotope ratios may reach several percent. The proposed operating modes of the detector, with allowance for its features, the design of the recording system, and use of formulas for calculating and correcting errors, allow their reduction to ∼0.10–0.01%
引用
收藏
页码:574 / 582
页数:8
相关论文
共 50 条
  • [31] High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers
    Cotter, Robert J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (05) : 657 - 674
  • [32] Linear type and a reflectron type time-of-flight mass spectrometers
    Saito, N.
    Koyama, K.
    Tanimoto, M.
    Denshi Gijutsu Sogo Kenkyusho Iho/Bulletin of the Electrotechnical Laboratory, 1998, 62 (06): : 23 - 30
  • [33] Miniature time-of-flight mass spectrometers for in situ composition studies
    Brinckerhoff, WB
    Cornish, TJ
    McEntire, RW
    Cheng, AF
    Benson, RC
    ACTA ASTRONAUTICA, 2003, 52 (2-6) : 397 - 404
  • [34] Multipass time-of-flight mass spectrometers with high resolving powers
    Casares, A
    Kholomeev, A
    Wollnik, H
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 206 (03) : 267 - 273
  • [35] Hybrid quadrupole/time-of-flight mass spectrometers for analysis of biomolecules
    Ens, W
    Standing, KG
    BIOLOGICAL MASS SPECTROMETRY, 2005, 402 : 49 - 78
  • [36] Direct sampling time-of-flight mass spectrometers for technological analysis
    Sysoev, AA
    Sysoev, AA
    Poteshin, SS
    Pyatakhin, VI
    Shchekina, IV
    Trofimov, AS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03): : 261 - 266
  • [37] Laser time-of-flight mass spectrometer
    Sysoev, AA
    Poteshin, SS
    Dryannov, AI
    Shchekina, IV
    Pyatakhin, VI
    Menshikov, RA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1997, 40 (04) : 508 - 512
  • [38] Compensation of large ion energy spreads by multigap grid reflectors in time-of-flight mass spectrometers
    I. I. Pilyugin
    Technical Physics, 2016, 61 : 446 - 452
  • [39] Compensation of large ion energy spreads by multigap grid reflectors in time-of-flight mass spectrometers
    Pilyugin, I. I.
    TECHNICAL PHYSICS, 2016, 61 (03) : 446 - 452
  • [40] Laser ablation ion-storage time-of-flight mass spectrometry
    Russo, RE
    Klunder, GL
    Grant, P
    Andresen, BD
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1999, 69 (Suppl 1): : S895 - S897