Verification of a New Model of the Irradiance Distribution from a Unidirectional Point Source in Water Using the Monte Carlo Method

被引:0
|
作者
A. G. Luchinin
M. Yu. Kirillin
L. S. Dolin
机构
[1] Institute of Applied Physics of the Russian Academy of Sciences,
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
We study the spatio-angular structure of a nonstationary light field produced in seawater by a unidirectional point source. The calculation results obtained using an analytical model, which allows for the photon spread over the propagation paths, and the statistical simulation method are compared. It is shown that the analytical model provides a good description of the amplitude-frequency characteristics of irradiance in a wide range of variation in the essential parameters of the problem, namely, the distance from the source, the angle reckoned from the radiation axis, and the frequency. Disagreement of the results of the analytical model and statistical simulation is observed at high frequencies and long distances where the approximations used during the model development are inapplicable.
引用
收藏
页码:321 / 331
页数:10
相关论文
共 50 条
  • [21] Verification of Transformer Restricted Earth Fault Protection by using the Monte Carlo Method
    Krstivojevic, Jelisaveta P.
    Djuric, Milenko B.
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2015, 15 (03) : 65 - 72
  • [22] Verification of a beam model in a treatment planninng system using an Monte Carlo approach
    Wieslander, E.
    Knoos, T.
    MEDICAL PHYSICS, 2007, 34 (06) : 2504 - 2504
  • [23] CONFORMATIONAL DISTRIBUTION OF HEPTAALANINE - ANALYSIS USING A NEW MONTE-CARLO CHAIN GROWTH METHOD
    VELIKSON, B
    GAREL, T
    NIEL, JC
    ORLAND, H
    SMITH, JC
    JOURNAL OF COMPUTATIONAL CHEMISTRY, 1992, 13 (10) : 1216 - 1233
  • [24] Verification of a Monte Carlo-Based Source Model for a Varian 10 MV Photon Beam
    Davidson, S.
    Cui, J.
    Deasy, J.
    Ibbott, G.
    Followill, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [25] A model of irradiance distribution for a directed point source in an infinite weakly absorbing turbid medium
    Dolin L.S.
    Sergeeva E.A.
    Radiophysics and Quantum Electronics, 2001, Springer Science and Business Media, LLC (44) : 858 - 865
  • [26] Quadrilateral mesh generation from point clouds by a Monte Carlo method
    Roth, Agoston
    Juhasz, Imre
    WSCG 2009, FULL PAPERS PROCEEDINGS, 2009, : 97 - +
  • [27] Brachytherapy source reconstruction for estimating the dose distribution and source position with SPECT system: Monte Carlo Method
    Park, MinSeok
    Jung, Haijo
    Kim, Gisub
    Ji, YoungHoon
    Park, SeYoung
    Kim, Jungmin
    Choi, InSeok
    Kim, Hyunji
    Yoon, YongSu
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [28] Quantifying the Dose Distribution of OBI CBCT Using Monte Carlo Simulations with a Measurement-Based Source Model
    McMillan, K.
    DeMarco, J.
    Tenn, S.
    Chow, P.
    McNitt-Gray, M.
    Ruan, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [29] Improvement of fission source distribution by correlated sampling method in Monte Carlo perturbation calculations
    Kim, Song Hyun
    Yamanaka, Masao
    Pyeon, Cheol Ho
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2018, 55 (08) : 945 - 954
  • [30] Simulation of critical dimension error using Monte Carlo method and its experimental verification
    Zinn, SY
    Lee, SW
    Choi, SW
    Sohn, JM
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2002, 20 (06): : 2606 - 2609