Wire Break Protection System for 0.38 and 6 – 10 KV Overhead Power Transmission Lines

被引:0
|
作者
Ershov A.M. [1 ]
Khlopova A.V. [1 ]
Sidorov A.I. [1 ]
机构
[1] South Ural State University (National Research University), Chelyabinsk
关键词
overhead transmission line; protection system; voltage; 0.38; and; 6; –; 10; kV; wire break;
D O I
10.1007/s10749-020-01228-5
中图分类号
学科分类号
摘要
Currently, there is no automation and protection equipment to detect wire breaks in 6 – 10/0.38 kV electric networks. A protection system based on microprocessor electricity meters installed in a 0.38 kV network for the automatic detection of a damaged section of 0.38 and 6 – 10 kV overhead lines is proposed. A functional diagram of the protection system is described. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.
引用
收藏
页码:434 / 437
页数:3
相关论文
共 50 条
  • [31] Lightning protection of overhead power distribution lines
    Yokoyama, Shigeru
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2007, 2 (05) : 491 - 496
  • [32] Experimental Study on Ultrasonic Detection Method of Ice Thickness for 10 kV Overhead Transmission Lines
    Yang, Lin
    Chen, Jie
    Hao, Yanpeng
    Li, Licheng
    Lin, Xinhao
    Yu, Lei
    Li, Yue
    Yuan, Zhiyong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [33] STANDARDIZATION OF OVERHEAD POWER TRANSMISSION-LINES
    BUDZKO, IA
    VENIKOV, VA
    NEKRASOV, AM
    ASTAKHOV, YN
    CHEREMISIN, NM
    ZUBKO, VM
    BLOK, WM
    ELECTRICAL TECHNOLOGY, 1984, (01): : 31 - 41
  • [34] Grounding of Overhead Transmission Lines for Improved Lightning Protection
    Chisholm, William A.
    Petrache, Emanuel
    Bologna, Fabio
    2010 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: SMART SOLUTIONS FOR A CHANGING WORLD, 2010,
  • [35] Icing Detector for Overhead Power Transmission Lines
    Moser, Michael J.
    George, Boby
    Zangl, Hubert
    Brasseur, Georg
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1078 - 1082
  • [36] An analysis of the condition of the 6-500 kV overhead power lines of the Samara region
    Khrennikov A.Yu.
    Gol'dshtein V.G.
    Skladchikov A.A.
    Power Technology and Engineering, 2010, 44 (04) : 322 - 326
  • [37] SUPPLYING FIXED AND STROBOSCOPIC LIGHT BEACONS FROM THE OVERHEAD GROUND WIRE ON 735 kv TRANSMISSION LINES.
    Blais, R.
    Berthiaume, R.
    1979,
  • [38] Ground wire energy extraction method for overhead transmission lines
    Huang, Huan
    Deng, Yulong
    Ma, Xiaohong
    Jiang, Xingliang
    Wu, Jianrong
    Hu, Qin
    Yang, Qi
    Lyu, Qianyong
    Yang, Liuqing
    He Jishu/Nuclear Techniques, 2023, 46 (05): : 40 - 49
  • [39] About lightning protection of overhead power lines 35 kV and 110 kV by antenna type long flashover arresters
    Podporkin, G.V.
    Pilshikov, V.E.
    Sivaev, A.D.
    Yarmarkin, M.K.
    Izvestiya Akademii Nauk. Energetika, 2003, (06): : 59 - 69
  • [40] CLEARANCE FOR OVERHEAD WIRE POWER TRANSMISSION USING KRENITE
    ROEDIGER, KJ