摘要
The thermal conductivity of thin, high-conducting ceramic bars—commonly used in mechanical tensile testing—is measured using a variant of the short transient hot-strip technique. As with similar contact transient methods, the influence from the thermal contact resistance between the sensor and the sample is accurately recorded and filtered out from the analysis—a specific advantage that enables sensitive measurements of the bulk properties of the sample material. The present concept requires sensors that are square in shape with one side having the same width as the bar to be studied. As long as this requirement is fulfilled, the particular size of the thin bar can be selected at will. This paper presents an application where the present technique is applied to study structural changes or degradation in reinforced carbon–carbon (RCC) bars exposed to thermal cycling. Simultaneously, tensile testing and monitoring of mass loss are conducted. The results indicate that the present approach may be utilized as a non-destructive quality control instrument to monitor local structural changes in RCC panels.
引用
收藏
页码:1816 / 1825
页数:9
相关论文
共 50 条
  • [31] THEORY OF TRANSIENT HOT-WIRE METHOD FOR MEASURING THERMAL-CONDUCTIVITY
    HEALY, JJ
    DEGROOT, JJ
    KESTIN, J
    PHYSICA B & C, 1976, 82 (02): : 392 - 408
  • [32] SIMULTANEOUS MEASUREMENT OF RESISTIVITY AND TEMPERATURE-COEFFICIENT OF RESISTIVITY OF METALLIC THIN-FILMS WITH THE TRANSIENT HOT-STRIP METHOD
    GUSTAFSSON, SE
    KARAWACKI, E
    KHAN, MN
    THIN SOLID FILMS, 1982, 92 (03) : 287 - 294
  • [33] THERMAL-CONDUCTIVITY OF ELECTRICALLY CONDUCTING LIQUIDS BY THE TRANSIENT HOT-WIRE METHOD
    BLEAZARD, JG
    TEJA, AS
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1995, 40 (04): : 732 - 737
  • [34] Influence of Participating Radiation on Measuring Thermal Conductivity of Translucent Thermal Insulation Materials with Hot Strip Method
    Hu Zhang
    Kefan Wu
    Guihua Tang
    Journal of Thermal Science, 2022, 31 : 1023 - 1036
  • [35] Influence of Participating Radiation on Measuring Thermal Conductivity of Translucent Thermal Insulation Materials with Hot Strip Method
    ZHANG Hu
    WU Kefan
    TANG Guihua
    JournalofThermalScience, 2022, 31 (04) : 1023 - 1036
  • [36] Influence of Participating Radiation on Measuring Thermal Conductivity of Translucent Thermal Insulation Materials with Hot Strip Method
    Zhang Hu
    Wu Kefan
    Tang Guihua
    JOURNAL OF THERMAL SCIENCE, 2022, 31 (04) : 1023 - 1036
  • [37] lMeasurement of the thermal conductivity of thin insulating anisotropic material with a stationary hot strip method
    Jannot, Yves
    Degiovanni, Alain
    Felix, Vincent
    Bal, Harouna
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (03)
  • [38] Measurements of the Thermal Effusivity of a Drop-Size Liquid Using the Pulse Transient Hot-Strip Technique
    M. Gustavsson
    H. Nagai
    T. Okutani
    International Journal of Thermophysics, 2005, 26 : 1803 - 1813
  • [39] Thermal conductivity characterization of ultra-thin silicon film using the ultra-fast transient hot strip method
    张燕燕
    程然
    倪东
    田明
    卢继武
    赵毅
    Chinese Physics B, 2019, 28 (07) : 503 - 507
  • [40] Thermal conductivity characterization of ultra-thin silicon film using the ultra-fast transient hot strip method
    Zhang, Yan-Yan
    Cheng, Ran
    Ni, Dong
    Tian, Ming
    Lu, Ji-Wu
    Zhao, Yi
    CHINESE PHYSICS B, 2019, 28 (07)