High-throughput, nontargeted metabolite fingerprinting using nominal mass flow injection electrospray mass spectrometry

被引:0
|
作者
Manfred Beckmann
David Parker
David P Enot
Emilie Duval
John Draper
机构
[1] Institute of Biological Sciences,
[2] Aberystwyth University,undefined
来源
Nature Protocols | 2008年 / 3卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Flow injection electrospray–mass spectrometry (FIE–MS) is finding utility as a first-pass metabolite fingerprinting tool in many research fields. We provide a protocol that has proved reliable in large-scale research projects involving diverse sample matrices originating from plants, microbes and mammalian biofluids. Using Brachypodium leaf material as an example matrix all steps are summarized from sample extraction to data quality assessment. Alternative procedures for dealing with other common matrices such as bloods and urine are included. With little sample pretreatment, no chromatography and instrument cycle times of <5 min it is feasible to analyze >1,000 samples per week. Analysis of a typical batch of 240 samples (including first-pass data analysis) can be accomplished within 48 h.
引用
收藏
页码:486 / 504
页数:18
相关论文
共 50 条
  • [21] High-throughput purity estimation and characterisation of synthetic peptides by electrospray mass spectrometry
    Smart, SS
    Mason, TJ
    Bennell, PS
    Maeij, NJ
    Geysen, HM
    INTERNATIONAL JOURNAL OF PEPTIDE AND PROTEIN RESEARCH, 1996, 47 (1-2): : 47 - 55
  • [22] High-throughput screening of catalysts by electrospray ionization tandem mass spectrometry.
    Chen, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U776 - U777
  • [23] Exploration of metabolite signatures using high-throughput mass spectrometry coupled with multivariate data analysis
    Zhang, Yanli
    Liu, Peng
    Li, Yuanfeng
    Zhang, Ai-Hua
    RSC ADVANCES, 2017, 7 (11) : 6780 - 6787
  • [24] The automatic visualisation of carry-over in high-throughput flow injection analysis mass spectrometry
    Richmond, R
    Görlach, E
    ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 175 - 183
  • [25] A high-throughput flow injection inductively coupled plasma mass spectrometry method for quantification of oligonucleotides
    Tu, Qiang
    Guidry, Erin N.
    Meng, Fanyu
    Wang, Tiebang
    Gong, Xiaoyi
    MICROCHEMICAL JOURNAL, 2016, 124 : 668 - 674
  • [26] High-throughput chemical residue analysis by fast extraction and dilution flow injection mass spectrometry
    Nanita, Sergio C.
    ANALYST, 2011, 136 (02) : 285 - 287
  • [27] High-Throughput, Accurate Mass Metabolome Profiling of Cellular Extracts by Flow Injection - Time-of-Flight Mass Spectrometry
    Fuhrer, Tobias
    Heer, Dominik
    Begemann, Boris
    Zamboni, Nicola
    ANALYTICAL CHEMISTRY, 2011, 83 (18) : 7074 - 7080
  • [28] Acoustic Ejection Mass Spectrometry: The Era of High-Throughput Mass Spectrometry
    Fischer, Gavin
    LC GC NORTH AMERICA, 2020, 38 (12) : 666 - 667
  • [29] InSourcerer: a high-throughput method to search for unknown metabolite modifications by mass spectrometry
    Mrzic, Aida
    Lermyte, Frederik
    Trung Nghia Vu
    Valkenborg, Dirk
    Laukens, Kris
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (17) : 1396 - 1404
  • [30] High-throughput quantification of soy isoflavones in human and rodent blood using liquid chromatography with electrospray mass spectrometry and tandem mass spectrometry detection
    Twaddle, NC
    Churchwell, MI
    Doerge, DR
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 777 (1-2): : 139 - 145