Toward the optimal waveform for electrical stimulation of human muscle

被引:0
|
作者
Scott D. Bennie
Jerrold S. Petrofsky
Jodi Nisperos
Mitchell Tsurudome
Mike Laymon
机构
[1] Department of Physical Therapy,
[2] Loma Linda University,undefined
[3] Loma Linda,undefined
[4] CA 92350,undefined
[5] USA,undefined
[6] Department of Physical Therapy,undefined
[7] Azusa Pacific University,undefined
[8] Azusa,undefined
[9] California,undefined
[10] USA,undefined
来源
关键词
Electrical stimulation Isometric exercise Waveform Comfort Physiological response;
D O I
暂无
中图分类号
学科分类号
摘要
Electrical stimulation of the quadriceps muscle was used to elicit 4-min isometric contractions at 10% of the maximal voluntary contraction (MVC) in four male and three female subjects. The effect of four waveforms, including Russian, interferential, sine, and square, on the mean stimulation current required to achieve the desired contraction force, subjective comfort, and physiological responses was studied. Interferential stimulation, even at full power, could not elicit a sustained contraction at 10% MVC. The contractions elicited by electrical stimulation utilizing the sine waveform required significantly less mean stimulation current to maintain the desired force of contraction with consistently lower verbal rating scale scores and greater increases in oxygen consumption than either the Russian or square waveform stimulations. Russian waveform stimulation produced a significantly greater rise in galvanic skin resistance than the sine or square waveform while the changes in respiratory quotient were similar between waveforms. The data support sine wave stimulation as working the best by producing the desired muscle tension with the least mean stimulation current and therefore, the least tissue trauma while providing the most subjective comfort.
引用
收藏
页码:13 / 19
页数:6
相关论文
共 50 条
  • [31] Muscle Stimulation Waveform Timing Patterns for Upper and Lower Leg Muscle Groups to Increase Muscular Endurance in Functional Electrical Stimulation Pedaling Using a Forward Dynamic Model
    Hakansson, Nils A.
    Hull, M. L.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (09) : 2263 - 2270
  • [32] Energy-efficient waveform for electrical stimulation of the cochlear nerve
    Marcus Yip
    Peter Bowers
    Victor Noel
    Anantha Chandrakasan
    Konstantina M. Stankovic
    Scientific Reports, 7
  • [33] EFFECTS OF WAVEFORM ON COMFORT DURING NEUROMUSCULAR ELECTRICAL-STIMULATION
    BAKER, LL
    BOWMAN, BR
    MCNEAL, DR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (233) : 75 - 85
  • [34] Energy-efficient waveform for electrical stimulation of the cochlear nerve
    Yip, Marcus
    Bowers, Peter
    Noel, Victor
    Chandrakasan, Anantha
    Stankovic, Konstantina M.
    SCIENTIFIC REPORTS, 2017, 7
  • [35] An Electrical Muscle Simulator Based on Functional Electrical Stimulation
    Wang, Haibin
    Guan, Guan
    He, Qing
    Zeng, Dewen
    Leng, Bin
    Xu, Hongwei
    Zheng, Weiming
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2012), 2012,
  • [36] Peripheral nerve stimulation-optimal gradient waveform design
    Schulte, Rolf F.
    Noeske, Ralph
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 518 - 522
  • [37] ELECTRICAL STIMULATION OF SKELETAL MUSCLE - A STUDY OF MUSCLE AS AN ACTUATOR
    CROCHETIERE, WJ
    VODOVNIK, L
    RESWICK, JB
    MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (02): : 111 - +
  • [38] RESPONSE OF STRIATED MUSCLE TO ELECTRICAL STIMULATION
    FORREST, JC
    BRISKEY, EJ
    JOURNAL OF FOOD SCIENCE, 1967, 32 (05) : 483 - &
  • [39] Mimicking muscle activity with electrical stimulation
    Johnson, Lise A.
    Fuglevand, Andrew J.
    JOURNAL OF NEURAL ENGINEERING, 2011, 8 (01)
  • [40] Variability in Muscle Adaptation to Electrical Stimulation
    Minetto, M. A.
    Botter, A.
    Bottinelli, O.
    Miotti, D.
    Bottinelli, R.
    D'Antona, G.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (06) : 544 - 553