Electrical stimulation Isometric exercise Waveform Comfort Physiological response;
D O I
暂无
中图分类号
学科分类号
摘要
Electrical stimulation of the quadriceps muscle was used to elicit 4-min isometric contractions at 10% of the maximal voluntary contraction (MVC) in four male and three female subjects. The effect of four waveforms, including Russian, interferential, sine, and square, on the mean stimulation current required to achieve the desired contraction force, subjective comfort, and physiological responses was studied. Interferential stimulation, even at full power, could not elicit a sustained contraction at 10% MVC. The contractions elicited by electrical stimulation utilizing the sine waveform required significantly less mean stimulation current to maintain the desired force of contraction with consistently lower verbal rating scale scores and greater increases in oxygen consumption than either the Russian or square waveform stimulations. Russian waveform stimulation produced a significantly greater rise in galvanic skin resistance than the sine or square waveform while the changes in respiratory quotient were similar between waveforms. The data support sine wave stimulation as working the best by producing the desired muscle tension with the least mean stimulation current and therefore, the least tissue trauma while providing the most subjective comfort.
引用
收藏
页码:13 / 19
页数:6
相关论文
共 50 条
  • [1] Toward the optimal waveform for electrical stimulation of human muscle
    Bennie, SD
    Petrofsky, JS
    Nisperos, J
    Tsurudome, M
    Laymon, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 88 (1-2) : 13 - 19
  • [2] Predicting optimal electrical stimulation for repetitive human muscle activation
    Chou, LW
    Ding, J
    Wexler, AS
    Binder-Macleod, SA
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (03) : 300 - 309
  • [3] CHANGE IN MUSCLE FORCE FOLLOWING ELECTRICAL-STIMULATION - DEPENDENCE ON STIMULATION WAVEFORM AND FREQUENCY
    STEFANOVSKA, A
    VODOVNIK, L
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1985, 17 (03): : 141 - 146
  • [4] Subjective sensation and force characteristics of electrical muscle stimulation due to waveform changes
    Ishimaru, Takaya
    Saga, Satoshi
    2022 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII 2022), 2022, : 908 - 913
  • [5] Effects of waveform shape on human sensitivity to electrical stimulation of the inner ear
    van Wieringen, A
    Carlyon, RP
    Laneau, J
    Wouters, J
    HEARING RESEARCH, 2005, 200 (1-2) : 73 - 86
  • [6] DualEMS: Two-Channel Arbitrary Waveform Electrical Muscle Stimulation Device to Design Interference Stimulation
    Ohara, Hiroki
    Hasegawa, Shoichi
    PROCEEDINGS OF AUGMENTED HUMANS CONFERENCE 2022 (AHS 2022), 2022, : 195 - 202
  • [7] Defibrillation: toward the optimal waveform shape
    Carranza, Gustavo
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2014, 43 (04): : 202 - 208
  • [8] Electrical Muscle Stimulator with Atypical Waveform
    P. S. Mart’yanov
    D. V. Churikov
    Journal of Communications Technology and Electronics, 2020, 65 : 1222 - 1225
  • [9] Electrical Muscle Stimulator with Atypical Waveform
    Mart'yanov, P. S.
    Churikov, D. V.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2020, 65 (10) : 1222 - 1225
  • [10] Toward an Optimal Algorithm for LiDAR Waveform Decomposition
    Qin, Yuchu
    Tuong Thuy Vu
    Ban, Yifang
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2012, 9 (03) : 482 - 486