A new magnetic sensor with Mach-Zehnder/Sagnac optical fiber interferometer

被引:0
|
作者
Li S. [1 ]
Li X. [1 ]
Wang X. [1 ]
Chen J. [1 ]
机构
[1] State Key Laboratory of Advanced Optical Communication Systems and Networks, Shanghai Jiao Tong University, Shanghai
来源
基金
中国国家自然科学基金;
关键词
Mach-Zehnder/Sagnac optical fiber interferometer; magnetic field sensor; optical fiber sensor;
D O I
10.1007/s12200-009-0038-4
中图分类号
学科分类号
摘要
This paper presents a new structure for magnetic sensor with Mach-Zehnder/Sagnac optical fiber interferometer. The magnetostrictive optical fiber sensor is placed in one of the two arms of the Mach-Zehnder interferometer, which can detect the optic phase shift by testing the length difference of the arm caused by environmental magnetic field. Because of forward and backward transmission in the arms, the Mach-Zehnder/Sagnac optical fiber interferometer can deduce twice exactly of the phase shift proportional to the length difference as Mach-Zehnder interferometer. Theoretically, description of the Mach-Zehnder/Sagnac interferometer is given, and some main issues in the magnetic field sensor with optical fiber interferometer are demonstrated with experiments. The magnetic sensors are implemented using the proposed methods. © 2009 Higher Education Press and Springer-Verlag GmbH.
引用
收藏
页码:192 / 194
页数:2
相关论文
共 50 条
  • [31] A voltage sensor utilizing all-fiber Mach-Zehnder interferometer
    Huang, YL
    Feng, DJ
    Xu, ZW
    Tong, ZG
    Kai, GY
    Dong, XY
    [J]. FIBER OPTICS AND OPTOELECTRONICS FOR NETWORK APPLICATIONS, 2001, 4603 : 188 - 191
  • [32] Highly Sensitive Temperature Fiber Sensor Based on Mach-Zehnder Interferometer
    Hsu, Jui-Ming
    Chen, Jian-Zhi
    Zheng, Wen-Hao
    [J]. FIBER AND INTEGRATED OPTICS, 2016, 35 (5-6) : 230 - 238
  • [33] Double-pass Mach-Zehnder fiber interferometer pH sensor
    Tou, Zhi Qiang
    Chan, Chi Chiu
    Hong, Jesmond
    Png, Shermaine
    Eddie, Khay Ming Tan
    Tan, Terence Aik Huang
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (04)
  • [34] Humidity Sensor Based on an In-Fiber Integrated Mach-Zehnder Interferometer
    Liu, Yin
    Lin, Hongfeng
    Dai, Yutang
    Zhou, Ai
    Yuan, Libo
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (05) : 393 - 396
  • [35] Intrusion Sensor Using Fiber-Optic Mach-Zehnder Interferometer
    Park, Hyoung Jun
    Song, Minho
    [J]. JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2006, 26 (04) : 255 - 259
  • [36] Mach-Zehnder interferometer based fiber-optic nitrate sensor
    Al Noman, Abdullah
    Dash, Jitendra Narayan
    Cheng, Xin
    Tam, Hwa-Yam
    Yu, Changyuan
    [J]. OPTICS EXPRESS, 2022, 30 (21) : 38966 - 38974
  • [37] Distributed fiber-optic sensor with a ring Mach-Zehnder interferometer
    Sun, Qizhen
    Liu, Deming
    Liu, Hairong
    Shum, P.
    [J]. PASSIVE COMPONENTS AND FIBER-BASED DEVICES IV, PTS 1 AND 2, 2007, 6781
  • [38] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    雷雪琴
    徐彦超
    于雅婷
    彭保进
    [J]. Optoelectronics Letters, 2019, 15 (01) : 43 - 47
  • [39] Ultrasensitive magnetic field sensor based on an in-fiber Mach-Zehnder interferometer with a magnetic fluid component
    Li, Zhengyong
    Liao, Changrui
    Song, Jun
    Wang, Ying
    Zhu, Feng
    Wang, Yiping
    Dong, Xiaopeng
    [J]. PHOTONICS RESEARCH, 2016, 4 (05) : 197 - 201
  • [40] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    Xue-qin Lei
    Yan-chao Xu
    Ya-ting Yu
    Bao-jin Peng
    [J]. Optoelectronics Letters, 2019, 15 : 43 - 47