Fluorescent determination of cardiolipin using 10-N-nonyl acridine orange

被引:0
|
作者
P. Kaewsuya
N. D. Danielson
D. Ekhterae
机构
[1] Miami University,Department of Chemistry and Biochemistry
[2] University of Pennsylvania,Department of Surgery, School of Medicine
来源
关键词
Fluorescence; Cardiolipin; Phospholipids; 10-N-nonyl acridine orange;
D O I
暂无
中图分类号
学科分类号
摘要
Cardiolipin (CL) plays an essential role as a marker for cell apoptosis. Quantitative detection of phospholipids (PLs) by UV absorbance is problematic due to the presence of few double bonds in the structure. Although 10-N-nonyl acridine orange (NAO) has been utilized for fluorescent visualization of liposomes and mitochondria through its interaction with CL, in this work, we have developed a specific fluorescent method for CL in solution using NAO. The interaction of sodium n-dodecyl sulfate (SDS), used to treat cells prior to lipid extraction, and other PLs found in cell membranes such as phosphatidic acid (PA), phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidylglycerol (PG), phosphatidiylserine (PS), and sphingomyelin (SM) with NAO is investigated. The fluorescence intensity of the 0.5 μM NAO signal is strongly quenched by SDS below 25% methanol in water but with a methanol content above 50%, no quenching of NAO by SDS is observed. No fluorescence quenching of NAO with a 50% methanol/50% water solvent by the previously mentioned PLs or 4–20 μM cholesterol with the exception of PG at above 8 μM is noted. Using this 50% methanol/50% water solvent, the fluorescence signal due to the NAO–CL interaction is quite stable from 3 to at least 15 min. With excitation and emission wavelengths set at 518 and 530 nm, respectively, 20 μM NAO provides an inverse linear fluorescence response at 0.2–10 μM CL with a correlation coefficient of 0.9929. The detection limit is 0.2 μM and the limit of quantification is 0.6 μM. Structurally analogous acridine orange and phenosafranin dyes are less effective as fluorescent probes for CL. The CL in the whole cell and membrane samples is quantitatively determined by standard addition to range from 0.2 to 1.5 μM. The level of CL in cell membrane samples, previously subjected to staurosporine which initiates cell apoptosis, is increased but not significantly through use of the t-test.
引用
收藏
页码:2775 / 2782
页数:7
相关论文
共 50 条
  • [41] THE DETERMINATION OF THE HEPARIN NEUTRALIZING CAPACITY OF PROTAMINE USING ACRIDINE-ORANGE FLUORESCENCE
    EDWARDS, HE
    NAVARATNAM, S
    ALLEN, JC
    PHILLIPS, GO
    THROMBOSIS AND HAEMOSTASIS, 1980, 43 (02) : 108 - 111
  • [42] Staining of mitochondrial membranes with 10-nonyl acridine orange MitoFluor Green, and MitoTracker Green is affected by mitochondrial membrane potential altering drugs
    Keij, JF
    Bell-Prince, C
    Steinkamp, JA
    CYTOMETRY, 2000, 39 (03): : 203 - 210
  • [43] Linear sweep polarographic determination of nucleic acids using acridine orange as a bioprobe
    Sun, Wei
    Zhao, Na
    Yuan, Xianlong
    Jiao, Kui
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2007, 72 (11) : 1085 - 1094
  • [44] Detection of Staphylococcus aureus using acridine orange-doped silica nanoparticles as a fluorescent label
    Jiang, Yan
    Xu, Yi
    Wang, Renjie
    Zhao, Bin
    Zhang, XiaoDan
    Zhao, Huazhou
    RSC ADVANCES, 2015, 5 (67) : 54338 - 54344
  • [45] Spectrofluorometric determination of caffeine using acridine orange-beta-cyclodextrin inclusion complex
    Park, Jong Hee
    Choi, Hee-Seon
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2013, 26 (06): : 353 - 356
  • [46] RAPID-DETERMINATION OF BACTERIURIA USING ACRIDINE-ORANGE COLORATION AND EPIFLUORESCENT MICROSCOPY
    PIRAULT, JL
    CAILLON, J
    JUVIN, ME
    DRUGEON, H
    ANNALES DE BIOLOGIE CLINIQUE, 1985, 43 (04) : 601 - 601
  • [47] CYTOLOGICAL STUDIES OF MOUSE EMBRYO CELLS INFECTED WITH POLYOMA VIRUS, USING ACRIDINE ORANGE AND FLUORESCENT ANTIBODY
    WILLIAMS, MG
    SHEININ, R
    VIROLOGY, 1961, 13 (03) : 368 - &
  • [48] AUTOMATED-ANALYSIS OF RETICULOCYTES USING FLUORESCENT STAINING WITH BOTH ACRIDINE-ORANGE AND AN IMMUNOFLUORESCENCE TECHNIQUE
    SELIGMAN, PA
    ALLEN, RH
    KIRCHANSKI, SJ
    NATALE, PJ
    AMERICAN JOURNAL OF HEMATOLOGY, 1983, 14 (01) : 57 - 66
  • [49] Determination of cell viability using acridine orange/propidium iodide dual-spectrofluorometry assay
    Hussain, Husniza
    Raj, Santhana L.
    Ahmad, Syahida
    Abd Razak, Mohd. Fuat
    Mohamud, Wan Nazaimoon Wan
    Bakar, Jamilah
    Ghazali, Hasanah Mohd.
    COGENT FOOD & AGRICULTURE, 2019, 5 (01):
  • [50] DETERMINATION OF CRITICAL MICELLE CONCENTRATION USING ACRIDINE-ORANGE DYE PROBE - UNDERGRADUATE EXPERIMENT
    RUJIMETHABHAS, M
    WILAIRAT, P
    JOURNAL OF CHEMICAL EDUCATION, 1978, 55 (05) : 342 - 342