Feasibility study of patient motion monitoring by using tactile array sensors

被引:0
|
作者
Tae-Ho Kim
Seong-Hee Kang
Dong-Su Kim
Min-Seok Cho
Kyeong-Hyeon Kim
Tae-Suk Suh
Siyong Kim
机构
[1] The Catholic University of Korea,Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine
[2] Virginia Commonwealth University,Department of Radiation Oncology
来源
关键词
Patient alignment; Patient setup; Tactile array sensor; IGRT;
D O I
暂无
中图分类号
学科分类号
摘要
An ideal alignment method based on the external anatomical surface of the patient should consider the entire region of interest. However, optical-camera-based systems cannot blindly monitor such areas as the patient’s back, for example. Furthermore, collecting enough information to correct the associated deformation error is impossible. The study aim is to propose a new patient alignment method using tactile array sensors that can measure the distributed pressure profiles along the contact surface. The TactArray system includes one sensor, a signal-conditioning device (USB drive/interface electronics, power supply, and cables), and a PC. The tactile array sensor was placed between the patient’s back and the treatment couch, and the deformations at different location on the patient’s back were evaluated. Three healthy male volunteers were enrolled in this study, and pressure profile distributions (PPDs) were obtained with and without immobilization. After the initial pretreatment setup using the laser alignment system, the PPD of the patient’s back was acquired. The results were obtained at four different times and included a reference PPD dataset. The contact area and the center-of-pressure value were also acquired based on the PPD data for a more elaborate quantitative data analysis. To evaluate the clinical feasibility of using the proposed alignment method for reducing the deformation error, we implemented a real-time self-correction procedure. Despite the initial alignment, we confirmed that PPD variations existed in both cases of the volunteer studies (with and without the use of the immobilization tool). Additionally, we confirmed that the contact area and the center of pressure varied in both cases, and those variations were observed in all three volunteers. With the proposed alignment method and the real-time selfcorrection procedure, the deformation error was significantly reduced. The proposed alignment method can be used to account for the limitation of the camera-based system and to improve the accuracy of the external surface-based patient setup.
引用
收藏
页码:199 / 203
页数:4
相关论文
共 50 条
  • [21] Continuous Home Monitoring of Essential Tremor Using Motion Sensors
    Pulliam, Christopher
    Eichenseer, Sheila
    Goetz, Christopher
    Waln, Olga
    Hunter, Christine
    Jankovic, Joseph
    Vaillancourt, David
    Giuffrida, Joseph
    Heldman, Dustin
    NEUROLOGY, 2013, 80
  • [22] CanoeSense: Monitoring Canoe Sprint Motion using Wearable Sensors
    Wang, Zhelong
    Wang, Jiaxin
    Zhao, Hongyu
    Yang, Ning
    Fortino, Giancarlo
    2016 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2016, : 644 - 649
  • [23] Motion classification using wireless sensors for activity monitoring in firefighting
    Nyugen, Nyugen
    Sundararajan, V.
    Zordan, Victor B.
    DETC2007: PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNOLOGY CONFERENCE AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 4, 2008, : 153 - 161
  • [24] A Review of Human Motion Monitoring Methods using Wearable Sensors
    Tu, Yaqing
    Liu, Linfeng
    Li, Ming
    Chen, Peng
    Mao, Yuwen
    INTERNATIONAL JOURNAL OF ONLINE ENGINEERING, 2018, 14 (10) : 168 - 179
  • [25] Continuous home monitoring of essential tremor using motion sensors
    Heldman, D.
    Pulliam, C.
    Eichenseer, S.
    Goetz, C.
    Waln, O.
    Hunter, C.
    Jankovic, J.
    Vaillancourt, D.
    Giuffrida, J.
    MOVEMENT DISORDERS, 2013, 28 : S335 - S335
  • [26] Motion Monitoring in Palliative Care Using Unobtrusive Bed Sensors
    Holtzman, M.
    Goubran, R.
    Knoefel, F.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5760 - 5763
  • [27] Agitation Monitoring of Persons with Dementia Based on Acoustic Sensors, Pressure Sensors and Ultrasound Sensors: A Feasibility Study
    Biswas, Jit
    Jayachandran, Maniyeri
    Thang, Pham Viet
    Fook, Victor Foo Siang
    Choo, Tay Siew
    Qiang, Qiu
    Takahashi, Shiro
    Jianzhong, Emily Hao
    Feng, Chen Jian
    Kiat, Philip Yap Lin
    PROMOTING INDEPENDENCE FOR OLDER PERSONS WITH DISABILITIES, 2006, 18 : 3 - 14
  • [28] Tactile Sensors using the Distributed Optical Fiber Sensors
    Heo, Jin-Seok
    Kim, Ju-Young
    Lee, Jung-Ju
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY, 2008, : 486 - +
  • [29] Some Peculiarities when Interfacing Resonance Tactile Array Sensors
    Kolev, Dimo
    Todorova, Velimira
    2017 XXVI INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS (ET), 2017,
  • [30] Feasibility of Bilateral Joint Flexion Monitoring Using Wearable Loop Sensors
    Mishra, Vigyanshu
    Kiourti, Asimina
    2024 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND INC/USNCURSI RADIO SCIENCE MEETING, AP-S/INC-USNC-URSI 2024, 2024, : 2629 - 2630