An Adequate Mathematical Model of an Ultrahigh-Voltage Overhead Transmission Line Using Synchronized Phasor Measurements

被引:0
|
作者
A. B. Balametov
E. D. Halilov
T. M. Isayeva
机构
[1] Azerbaijan Scientific-Research and Design-Prospecting Institute of Power Engineering,
[2] Azerbaijan State University of Oil and Industry,undefined
关键词
Mathematical model; Ultrahigh-voltage overhead line; Power losses; Corona losses; PMU measurements; Electrical parameters of overhead line; State estimation; Line section;
D O I
暂无
中图分类号
学科分类号
摘要
Methodical errors of simplified models of steady state of ultrahigh-voltage overhead lines have been investigated. It has been established that the error of these models does not correspond to the accuracy of PMU measurements. A method and algorithm for improving the accuracy of modeling by the mode parameters collected from PMU devices have been proposed. Chain model of an overhead line proposed in this paper takes actual weather conditions into account. Application of the proposed approach makes it possible to increase the accuracy of calculating steady state and state estimation and identifying the electrical parameters of the overhead line. This improves the effectiveness of transmission line control in real time. Proposed method was applied for existing 500-kV ultrahigh-voltage overhead line.
引用
收藏
页码:175 / 183
页数:8
相关论文
共 50 条
  • [21] Determination of Voltage Control Area Based on Bus Coherency Using Synchronized Phasor Measurements
    Kibriya, Fazle
    Mahto, Dinesh Kumar
    Khalkho, Anant Milan
    Mahto, Tarkeshwar
    Mohanta, Dusmanta Kumar
    [J]. PROCEEDINGS OF THE 2019 IEEE REGION 10 CONFERENCE (TENCON 2019): TECHNOLOGY, KNOWLEDGE, AND SOCIETY, 2019, : 1869 - 1874
  • [22] Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System
    Gill Estevez, P. D.
    Elizondo, M.
    Galarza, C.
    [J]. 2018 IEEE BIENNIAL CONGRESS OF ARGENTINA (ARGENCON), 2018,
  • [23] On-line Estimation of Transmission Line Parameters Using Synchronized Measurements
    Al-Othman, Abdulrahman K.
    El-Naggar, Khaled M.
    AlSharidah, Michel E.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (02) : 233 - 239
  • [24] Fault Location Scheme on a Three Phase Transmission Line using Synchronized Phasor Measurement
    Anees, Ahmed Sharique
    Jamil, Majid
    Rizwan, M.
    [J]. 2012 IEEE 5TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE 2012), 2012,
  • [25] Detection of Errors in Three-Phase Line Models Using Synchronized Phasor Measurements
    Khalili, Ramtin
    Abur, Ali
    [J]. 2020 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE 2020): SMART GRIDS: KEY ENABLERS OF A GREEN POWER SYSTEM, 2020, : 1131 - 1135
  • [26] Transmission Power System Dynamic Mathematical Model Based On Synchronized Measurements
    Ivankovic, Igor
    Skok, Srdjan
    Avramovic, Boris
    [J]. 2017 IEEE MANCHESTER POWERTECH, 2017,
  • [27] Interarea Model Estimation for Radial Power System Transfer Paths With Intermediate Voltage Control Using Synchronized Phasor Measurements
    Chakrabortty, Aranya
    Chow, Joe H.
    Salazar, Armando
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) : 1318 - 1326
  • [28] Mathematical Model of Overhead Line for Mode Control Based on the Vector Measurements
    Balametov, A.
    Khalilov, E.
    Isayeva, T.
    [J]. IFAC PAPERSONLINE, 2018, 51 (30): : 468 - 472
  • [29] Real-time estimation of security from voltage collapse using synchronized phasor measurements
    Khatib, AR
    Nuqui, RF
    Ingram, MR
    Phadke, AG
    [J]. 2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 582 - 588
  • [30] Fault Location in Long Transmission Lines Using Synchronized Phasor Measurements from Both Ends
    Mekhamer, S. F.
    Abdelaziz, A. Y.
    Ezzat, M.
    Abdel-Salam, T. S.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (07) : 759 - 776