The intra- and inter-examiner reliability of quantitative light-induced fluorescence (QLF) analyses

被引:25
|
作者
Pretty I.A. [1 ,5 ]
Hall A.F. [2 ]
Smith P.W. [3 ]
Edgar W.M. [4 ]
Higham S.M. [1 ]
机构
[1] University of Liverpool, Dept. of Clinical Dental Sciences
[2] University of Glasgow, Department of Restorative Dentistry
[3] University of Manchester, Department of Prosthodontics
[4] University of Liverpool, Clinical Dental Sciences
[5] University of Liverpool, Dept. of Clinical Dental Sciences, Edwards Building, Liverpool L69 3GN, Daulby Street
关键词
D O I
10.1038/sj.bdj.4801496
中图分类号
学科分类号
摘要
Objective: To assess the reliability of the analysis stage of quantitative light-induced fluorescence (QLF), The QLF analysis involves subjective input from the user and this study examines the influence of this on the reproducibility of the QLF data. Method: QLF images were taken of 20 human molar teeth that had been previously subjected to a demineralising solution (phosphoric acid 37%) to create artificial white spot lesions on their buccal surfaces. Following examination of the images, 16 were chosen to represent a range of lesion size and severity. Three copies were made of the images and each was allocated a different filename. 10 examiners in three centres were asked to analyse each of the 16 images on three occasions, with at least seven days between each attempt. Simple instructions describing the analysis procedure were supplied and examiners were asked to adhere to these directions. Examiners were asked to rate each of the 16 teeth on their first attempt both quantitatively (5 point scale) and qualitatively in terms of difficulty of analysis. Data reported were the ΔQ at 5% threshold for each tooth on each of three attempts. Results: Using ANOVA and paired t-tests to detect statistical differences, the three attempts of each examiner were used to determine intra-examiner reliability. Only one examiner (a novice at the technique) demonstrated differences between all three attempts and two demonstrated difference between one attempt. When the mean scores were compared to determine the inter-examiner reliability, only one examiner's results were statistically different when compared with two others Conclusion: This study has demonstrated that the analysis stage of QLF is reliable between examiners and within multiple attempts by the same examiner, when analysing in vitro lesions. Novices at the technique should be trained before analysing experimental data.
引用
收藏
页码:105 / 109
页数:4
相关论文
共 50 条
  • [31] Inter-examiner, intra-session and inter-session reliability of gait measurement
    Leszczewska, Justyna
    Czaprowski, Dariusz
    Pawlowska, Paulina
    Bialobrzewska, Karolina
    Gebicka, Anna
    Kotwicki, Tomasz
    RESEARCH INTO SPINAL DEFORMITIES 8, 2012, 176 : 155 - 158
  • [32] INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF NERVE-CONDUCTION MEASUREMENTS IN NORMAL SUBJECTS
    CHAUDHRY, V
    CORNBLATH, DR
    MELLITS, ED
    AVILA, O
    FREIMER, ML
    GLASS, JD
    REIM, J
    RONNETT, GV
    QUASKEY, SA
    KUNCL, RW
    ANNALS OF NEUROLOGY, 1991, 30 (06) : 841 - 843
  • [33] Intra- and inter-examiner variations in four dental methods for age estimation of children
    Reventlid, M
    Mornstad, H
    Teivens, A
    SWEDISH DENTAL JOURNAL, 1996, 20 (04) : 133 - 139
  • [34] Intra- and Inter-Examiner Reliability of Kinovea for Hip Flexion Angle Measurement During Straight Leg Raise Test
    Rabanal-Rodriguez, Gabriel
    Navarro-Santana, Marcos Jose
    Valera-Calero, Juan Antonio
    Munoz-Rodriguez, Ana
    Hernandez-Gonzalez, Elias
    Plaza-Manzano, Gustavo
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [35] The susceptibility of bleached enamel to staining as measured by Quantitative Light-induced Fluorescence (QLF)
    Adeyemi, A. A.
    Pender, N.
    Higham, S. M.
    INTERNATIONAL DENTAL JOURNAL, 2008, 58 (04) : 208 - 212
  • [36] Quantitative light-induced fluorescence (QLF):: a method for assessment of incipient caries lesions
    Angmar-Månsson, B
    ten Bosch, JJ
    DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (06) : 298 - 307
  • [37] INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF UPPER CERVICAL X-RAY MARKING SYSTEM
    SANSONE, M
    WOOLEY, JR
    GRANNIS, GH
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 1986, 9 (04) : 285 - 285
  • [38] INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF NERVE-CONDUCTION MEASUREMENTS IN PATIENTS WITH DIABETIC NEUROPATHY
    CHAUDHRY, V
    CORNBLATH, DR
    CORSE, AM
    FREIMER, ML
    GLASS, JD
    KUNCL, RW
    MELLITS, ED
    QUASKEY, SA
    NEUROLOGY, 1993, 43 (04) : A323 - A323
  • [39] Intra-examiner and inter-examiner reliability using a probe with .7mm markings.
    Pollock, S
    Tedder, D
    Streckfus, C
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1106 - 1106
  • [40] INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF THE UPPER CERVICAL X-RAY MARKING SYSTEM
    SIGLER, DC
    HOWE, JW
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 1985, 8 (02) : 75 - 80