Optimization of moderator assembly for neutron flux measurement: experimental and theoretical approaches

被引:0
|
作者
Abdul Waheed
Nawab Ali
Muzahir A. Baloch
Aziz A. Qureshi
Eid A. Munem
Muhammad Usman Rajput
Tauseef Jamal
Wazir Muhammad
机构
[1] COMSATS Institute of Information Technology (CIIT),Radiation Physics Laboratory, Physics Department
[2] Pakistan Institute of Nuclear Science and Technology (PINSTECH),Physics Division
[3] Majmaah University,Department of Physics, College of Science
[4] University Science Malaysia,School of Physics
[5] Pakistan Institute Engineering and Applied Sciences (PIEAS),DCIS
[6] Pakistan Institute of Nuclear Science and Technology (PINSTECH),Health Physics Division (HPD)
来源
关键词
Am–Be and ; Cf neutron sources; BF; & ; He detectors; Paraffin wax; Neutron flux; Monte Carlo simulation;
D O I
暂无
中图分类号
学科分类号
摘要
A moderator of paraffin wax assembly has been demonstrated where its thickness can be optimized to thermalize fast neutrons. The assembly is used for measuring fast neutron flux of a neutron probe at different neutron energies, using BF3 (Φ1″ and 2″) and 3He(Φ0.5″) neutron detectors. The paraffin wax thickness was optimized at 6 cm for the neutron probe which contains an Am–Be neutron source. The experimental data are compared with Monte Carlo simulation results using MCNP5 version 1.4. Neutron flux comparison and neutron activation techniques are used for measuring neutron flux of the neutron probe to validate the optimum paraffin moderator thickness in the assembly. The neutron fluxes are measured at (1.17 ± 0.09) × 105 and (1.19 ± 0.1) × 105 n/s, being in agreement with the simulated values. The moderator assembly can easily be utilized for essential requirements of neutron flux measurements.
引用
收藏
相关论文
共 50 条
  • [21] MEASUREMENT OF THERMAL NEUTRON FLUX
    CARTER, RS
    MUEHLHAUSE, CO
    MYERS, VW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 414 - +
  • [22] Special absorber neutron detector moderator assembly:: A new detector system for flux measurements of collimated 2.5 MeV neutrons
    Wolle, B
    Bätzner, R
    Baloui, T
    Gonda, G
    Klein, H
    Wiegel, B
    Wittstock, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 1194 - 1196
  • [23] A channel for neutron flux measurement
    Chuklyaev, SV
    Pepyolyshev, YN
    Artem'ev, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (02) : 162 - 166
  • [24] Underground neutron flux measurement
    Rindi, Alessandro
    Celani, Francesco
    Lindozzi, Marco
    Miozzi, Silvia
    Nuclear instruments and methods in physics research, 1988, 272 (03): : 871 - 874
  • [25] Special absorber neutron detector moderator assembly: a new detector system for flux measurements of collimated 2.5 MeV neutrons
    Wolle, B.
    Batzner, R.
    Baloui, T.
    Gonda, G.
    Klein, H.
    Wiegel, B.
    Wittstock, J.
    Review of Scientific Instruments, 1999, 70 (1 pt 2):
  • [26] DIRECT MEASUREMENT OF NEUTRON FLUX
    FUJIIE, Y
    SUITA, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1966, 3 (02): : 83 - &
  • [27] A Channel for Neutron Flux Measurement
    S. V. Chuklyaev
    Yu. N. Pepyolyshev
    V. A. Artem'ev
    Instruments and Experimental Techniques, 2002, 45 : 162 - 166
  • [28] A channel for neutron flux measurement
    Chuklyaev, S.V.
    Pepyolyshev, Yu.N.
    Artem'ev, V.A.
    Pribory i Tekhnika Eksperimenta, 2002, 45 (02): : 21 - 25
  • [29] MEASUREMENT OF THE NEUTRON FLUX IN SPACE
    HESS, WN
    STARNES, AJ
    PHYSICAL REVIEW LETTERS, 1960, 5 (02) : 48 - 50
  • [30] The Design of Target and Moderator to Produce a Neutron Flux Suitable for Boron Neutron Capture Therapy
    Meng, Y.
    Watanabe, Y.
    Broadhurst, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E348 - E348