ECG-gated multi-detector row spiral CT in the assessment of myocardial infarction: correlation with non-invasive angiographic findings

被引:0
|
作者
Marco Francone
Iacopo Carbone
Massimiliano Danti
Katia Lanciotti
Mario Cavacece
Francesca Mirabelli
Carlo Gaudio
Carlo Catalano
Roberto Passariello
机构
[1] University of Rome La Sapienza,Department of Radiological Sciences
[2] University of Rome La Sapienza,Department of Cardiovascular and Respiratory Sciences
[3] University of Rome La Sapienza,Department of Cardiology, Institute of Heart and Great Vessels “A. Reale”
来源
European Radiology | 2006年 / 16卷
关键词
Multidetector computed tomography; Myocardial infarction; Coronary artery disease;
D O I
暂无
中图分类号
学科分类号
摘要
Our objective was to retrospectively evaluate the ability of multidetector-row computed tomography (MDCT) to detect previous myocardial infarctions (MIs) and to correlate necrosis with the status of coronary arteries supplying the infarcted territory. After having clinically evaluated 187 patients referred for ECG-gated MDCT of the coronary arteries, 30 previous MIs were identified in 29 patients (9 recent and 21 chronic). MDCT data were evaluated qualitatively and quantitatively by measuring attenuation values and wall thickness within the infarcted region and normal adjacent myocardium. Each MI was also assigned to the distribution territory of a coronary vessel, and morphological data were combined with MDCT angiographic findings. MDCT was able to detect 25/30 MIs showing an overall sensitivity and specificity of 83 and 91%, respectively. Quantitative analysis revealed a statistically significant difference in attenuation values between normal and infarcted regions (38.9±14 HU vs. 104.0±16 HU). Regional wall thinning was observed in chronic MIs (4.1±2 mm vs. 10.5±3.8 mm), and not in patients with recent event (7.9±1.6 mm vs 9.1±4 mm). In 22/25 cases, MDCT angiographic findings showed the presence of suspicious critical lumen narrowing (n=3), previous coronary stenting (n=14) and surgical revascularization (n=5) in the infarct-related coronary. During a single examination, MDCT might provide comprehensive imaging of MI offering a combined morphological and angiographic assessment.
引用
收藏
页码:15 / 24
页数:9
相关论文
共 50 条
  • [41] Non-invasive assessment of coronary stenosis using multi-detector computer tomography: a comparative study with intravascular ultrasound
    Leber, A
    Knez, A
    Becker, A
    Von Ziegler, F
    Becker, C
    Boekstegers, P
    EUROPEAN HEART JOURNAL, 2004, 25 : 369 - 369
  • [42] Evaluation of non-calcified coronary plaques with ECG-gated multi-slice spiral CT: A phantom study and initial clinical experience
    Kopp, AF
    Ohnesorge, BM
    Schroeder, S
    Kuettner, A
    Georg, C
    Claussen, CD
    RADIOLOGY, 2000, 217 : 234 - 234
  • [43] Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography
    Santos, Raul D.
    Miname, Marcio H.
    Martinez, Lilton R. C.
    Rochitte, Carlos E.
    Chacra, Ana P. M.
    Nakandakare, Edna R.
    Chen, David
    Schaefer, Ernst J.
    ATHEROSCLEROSIS, 2008, 197 (02) : 910 - 915
  • [44] Noninvasive Assessment Of Coronary Artery Bypass Graft With 64-Slice Multi-Detector Row CT: Comparison With Invasive Coronary Angiography
    Urdiales, Pedro L.
    De La Vega, Alejandro
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 73D - 73D
  • [45] Assessment of coronary artery motion during the cardiac cycle to determine optimal reconstruction intervals for ECG-gated Multi-slice Spiral CT angiography
    Allkemper, T
    Fischbach, RM
    Juergens, K
    Grude, M
    Opitz, C
    Heindel, WL
    RADIOLOGY, 2001, 221 : 502 - 502
  • [46] Non-invasive investigation of coronary artery bypass grafts using multi-detector spiral computed tomography with sub-millimeter collimation
    Ropers, D
    Baum, U
    Anders, K
    Pohle, K
    Bautz, W
    Daniel, WG
    Achenbach, S
    EUROPEAN HEART JOURNAL, 2003, 24 : 568 - 568
  • [47] Acute myocardial infarction:: Assessment of left ventricular function with 16-detector row spiral CT versus MR imaging -: Study in pigs
    Mahnken, AH
    Katoh, M
    Bruners, P
    Spuentrup, E
    Wildberger, JE
    Günther, RW
    Buecker, A
    RADIOLOGY, 2005, 236 (01) : 112 - 117
  • [48] Non-invasive angiogenesis assessment with PET/CT in a rabbit model of myocardial infarction: feasibility and comparison with molecular markers
    Grandjean, C. E.
    Korshin, A.
    Smerup, M.
    Jensen, J. K.
    Follin, B.
    Brandt-Larsen, M.
    Pedersen, S. F.
    Ripa, R. S.
    Binderup, T.
    Kjaer, A.
    EUROPEAN HEART JOURNAL, 2019, 40 : 672 - 672
  • [49] ECG non-gated multi-detector computed tomography protocol prior to catheter ablation of atrial fibrillation provides sufficient data quality with lower radiation exposure compared to ECG-gated protocol.A prospective, randomized and blinded study
    Tudos, Zbynek
    Skala, Tomas
    Homola, Martin
    Moravec, Ondrej
    Taborsky, Milos
    Kocher, Martin
    Cerna, Marie
    Ctvrtlik, Filip
    Odstrcil, Frantisek
    Langova, Katerina
    Klementova, Olga
    BIOMEDICAL PAPERS-OLOMOUC, 2018, 162 (04): : 310 - 318
  • [50] Body surface mapping and the 12-lead ECG for non-invasive assessment of reperfusion following thrombolytic therapy in acute myocardial infarction
    Menown, IBA
    McMechan, SR
    Allen, J
    Anderson, J
    Adgey, AAJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 137A - 137A