Computer-controlled endoscopic performance assessment system

被引:0
|
作者
G. B. Hanna
T. Drew
P. Clinch
B. Hunter
A. Cuschieri
机构
[1] Department of Surgery,
[2] Ninewells Hospital & Medical School,undefined
[3] University of Dundee,undefined
[4] Dundee Tayside DD1 9SY,undefined
[5] Scotland,undefined
[6] Directorate of Medical Physics,undefined
[7] Ninewells Hospital & Medical School,undefined
[8] University of Dundee,undefined
[9] Dundee Tayside DD1 9SY,undefined
[10] Scotland,undefined
来源
Surgical Endoscopy | 1998年 / 12卷
关键词
Key words: Minimal access surgery—Task performance—Psychomotor skills;
D O I
暂无
中图分类号
学科分类号
摘要
We have devised an advanced computer-controlled system (ADEPT) for the objective evaluation of endoscopic task performance. The system’s hardware consists of a dual gimbal mechanism that accepts a variety of 5.0-mm standard endoscopic instruments for manipulation in a precisely mapped and enclosed work space. The target object consists of a sprung base plate incorporating various tasks. It is covered by a sprung perforated transparent top plate that has to be moved and held in the correct position by the operator to gain access to the various tasks. Standard video endoscope equipment provides the visual interface between the operator and the target-instrument field. Different target modules can be used, and the level of task difficulty can be adjusted by varying the manipulation, elevation, and azimuth angles. The system’s software is designed to (a) prompt the surgeon with the information necessary to perform the task, (b) collect and collate data on performance during execution of specified tasks, and (c) save the data for future analysis. The system was alpha and beta tested to ensure that all functions operated correctly.
引用
收藏
页码:997 / 1000
页数:3
相关论文
共 50 条
  • [1] Computer-controlled endoscopic performance assessment system
    Hanna, GB
    Drew, T
    Clinch, P
    Hunter, B
    Cuschieri, A
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (07): : 997 - 1000
  • [2] A computer-controlled voltametry system
    不详
    TENSIDE SURFACTANTS DETERGENTS, 1999, 36 (01) : 28 - 28
  • [3] A COMPUTER-CONTROLLED STEREOTAXIC SYSTEM
    SIEGEL, L
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1969, BM16 (03) : 197 - &
  • [4] COMPUTER-CONTROLLED TELECONTROL SYSTEM
    BENEZ, H
    GORTZ, B
    TUCHEL, L
    SIEMENS ZEITSCHRIFT, 1978, 52 (11): : 601 - 605
  • [5] COMPUTER-CONTROLLED INTERLOCKING SYSTEM
    ANDERSSON, HS
    HAGELIN, G
    ERICSSON REVIEW, 1981, 58 (02): : 74 - 80
  • [6] A COMPUTER-CONTROLLED MICROFILM SYSTEM
    HAWKINSO.B
    DATAMATION, 1970, 16 (03): : 119 - &
  • [7] COMPUTER-CONTROLLED PULSER SYSTEM
    JENSEN, D
    KREISLER, M
    LOMANNO, F
    POSTER, R
    RABIN, M
    SMART, P
    WISE, J
    DAKIN, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (03): : 503 - 508
  • [8] RISK ASSESSMENT OF COMPUTER-CONTROLLED SYSTEMS
    FRYER, MO
    IEEE TRANSACTIONS ON SOFTWARE ENGINEERING, 1985, 11 (01) : 125 - 129
  • [9] PROPOFOL FOR SEDATION DURING ENDOSCOPY - ASSESSMENT OF A COMPUTER-CONTROLLED INFUSION SYSTEM
    CHURCH, JA
    STANTON, PD
    KENNY, GNC
    ANDERSON, JR
    GASTROINTESTINAL ENDOSCOPY, 1991, 37 (02) : 175 - 179
  • [10] COMPUTER-CONTROLLED STEREOTAXIC RADIOTHERAPY SYSTEM
    HOUDEK, PV
    SCHWADE, JG
    SERAGO, CF
    LANDY, HJ
    PISCIOTTA, V
    WU, XD
    MARKOE, AM
    LEWIN, AA
    ABITBOL, AA
    BUJNOSKI, JL
    MARIENBERG, ES
    FIEDLER, JA
    GINSBERG, MS