Technical and clinical validation of three commercial real-time PCR kits for the diagnosis of neuroborreliosis in cerebrospinal fluid on three different real-time PCR platforms

被引:0
|
作者
L. Maes
T. Carolus
V. De Preter
S. Ignoul
R. Cartuyvels
L. Braeken
P.-J. D’Huys
V. Saegeman
B. Kabamba
M. Raymaekers
机构
[1] Research group Lab4U,Translational Research Center for Gastrointestinal Disorders (TARGID)
[2] Group of Management and Technology,Clinical Biology, Laboratory for Molecular Diagnostics, Campus Salvator
[3] UC Leuven-Limburg,Research group Lab4U, Faculty of Industrial Engineering
[4] University Hospital Gasthuisberg,Department of Laboratory Medicine
[5] KULeuven,Department of Microbiology and Immunology
[6] Jessa Hospital,Clinical Microbiology, Laboratory of Microbiology
[7] KU Leuven - Campus Diepenbeek,undefined
[8] University Hospitals Leuven,undefined
[9] KU Leuven,undefined
[10] University Clinic St-Luc UCL,undefined
关键词
Sensu Stricto; Borrelia Burgdorferi; Lyme Borreliosis; Lyme Neuroborreliosis; ospA Gene;
D O I
暂无
中图分类号
学科分类号
摘要
This study reports the evaluation of the technical and clinical validation of the O-DiaBorburg kit (DIA), Borrelia burgdorferi PCR kit, ISEX (GENE), and Borrelia burgdorferi sensu lato Real-TM (SAC) for the diagnosis of neuroborreliosis in cerebrospinal fluid based on both Borrelia DNA and CSF samples from patients with clinical suspicion of neuroborreliosis. This validation study was done by analysing the kits on the Rotorgene Q (RGQ), CFX96, and LightCycler480 (LC480). For all kits, the linear range was larger on RGQ than on CFX96 and LC480. A good reproducibility was obtained for all assays on all instruments. Storage at −20 °C resulted in a decreased reproducibility for SAC. Results of the limit of detection (LOD95) experiments indicated a better sensitivity than described in the kit insert for all kits on all PCR platforms. No cross-reactivity was found for genetically related organisms nor for other pathogens which may be present in CSF. All species of the Borrelia burgdorferi sensu lato complex were detected with the GENE and SAC kits. The DIA kit failed to detect B. lusitaniae. The results seemed to indicate a better overall performance for the GENE kit on RGQ. However, its diagnostic value could not be confirmed in the clinical validation study, wherein none of the 103 CSF samples from clinical neuroborreliosis cases showed a positive real-time PCR result with the GENE kit analysed on RGQ.
引用
收藏
页码:273 / 279
页数:6
相关论文
共 50 条
  • [21] A comparative study of commercial real-time reverse transcription PCR kits for forensic body fluid identification
    Lynch, Courtney
    Fleming, Rachel
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2023, 55 (05) : 656 - 669
  • [22] Validation of a real-time PCR for Haemophilus parasuis
    Turni, C.
    Pyke, M.
    Blackall, P. J.
    JOURNAL OF APPLIED MICROBIOLOGY, 2010, 108 (04) : 1323 - 1331
  • [23] Comparison of three real-time PCR for the quantification of polyomavirus BK
    Stellrecht, A.
    Espino, A. A.
    Nattanmai, S. M.
    Jackson, W. F.
    Conti, D. J.
    JOURNAL OF CLINICAL VIROLOGY, 2013, 56 (04) : 354 - 359
  • [24] Mpox detection in clinical specimens by three commercial real-time PCR assays demonstrates comparable results
    Hurley, Siobhan
    Kim, Ki Wook
    Domazetovska, Ana
    Yau, Cynthia
    Yeang, Malinna
    Donovan, Linda
    Kok, Jen
    Rawlinson, William
    PATHOLOGY, 2024, 56 (05)
  • [25] Real-time PCR for diagnosis of imported schistosomiasis
    Guegan, Helene
    Fillaux, Judith
    Charpentier, Elena
    Robert-Gangneux, Florence
    Chauvin, Pamela
    Guemas, Emilie
    Boissier, Jerome
    Valentin, Alexis
    Cassaing, Sophie
    Gangneux, Jean-Pierre
    Berry, Antoine
    Iriart, Xavier
    PLOS NEGLECTED TROPICAL DISEASES, 2019, 13 (09):
  • [26] Real-time PCR applications for diagnosis of leishmaniasis
    Luca Galluzzi
    Marcello Ceccarelli
    Aurora Diotallevi
    Michele Menotta
    Mauro Magnani
    Parasites & Vectors, 11
  • [27] Real-time quantitative PCR for toxoplasmosis diagnosis
    Ordinaire, I
    Simon, A
    Fréalle, E
    Soula, F
    Valat, AS
    Rouland, V
    Subtil, D
    Dei-Cas, E
    Camus, D
    Delhaes, L
    ANNALES DE BIOLOGIE CLINIQUE, 2005, 63 (01) : 67 - 73
  • [28] Real-Time PCR for Diagnosis of Oculoglandular Tularemia
    Maurin, Max
    Castan, Bernard
    Roch, Nathalie
    Gestin, Brieuc
    Pelloux, Isabelle
    Mailles, Alexandra
    Chicluet, Christophe
    Chavanet, Pascal
    EMERGING INFECTIOUS DISEASES, 2010, 16 (01) : 152 - 153
  • [29] Real-time PCR in the diagnosis of congenital toxoplasmosis
    Villar, Bianca Balzano De La Fuente
    Gomes, Leonardo Henrique Ferreira
    Portari, Elyzabeth Avvad
    Ramos, Carla Nasser Patrocinio
    Rocha, Danielle Nascimento
    Pereira, Jose Paulo
    Neves, Elizabeth de Souza
    Guida, Leticia da Cunha
    BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2023, 27 (05):
  • [30] HLA DISEASE DIAGNOSIS BY REAL-TIME PCR
    Fouquet, Baptiste
    Derai, David
    Gorochov, Guy
    Boudifa, Abdelali
    HLA, 2020, 95 (04) : 402 - 402