Flow-injection potentiometric determination of trace concentrations of chloride ions in low-mineralized natural waters

被引:0
|
作者
E. V. Telegina
A. L. Moskvin
A. V. Mozzhukhin
机构
[1] ZAO NPO Granit-NEMP,
来源
关键词
natural waters; potentiometry; chloride ion;
D O I
暂无
中图分类号
学科分类号
摘要
A procedure is developed for flow-injection potentiometric determination of trace chloride ions in low-mineralized waters and atmospheric precipitations. The procedure excludes the stage of preliminary ion-exchange concentration. The quantification limit in a 5-min analysis is 0.4 mg/L.
引用
收藏
页码:1041 / 1044
页数:3
相关论文
共 50 条
  • [31] SPECTROPHOTOMETRIC DETERMINATION OF NITRITE IN NATURAL-WATERS BY FLOW-INJECTION ANALYSIS
    NAKASHIMA, S
    YAGI, M
    ZENKI, M
    TAKAHASHI, A
    TOEI, K
    ANALYTICA CHIMICA ACTA, 1983, 155 (DEC) : 263 - 268
  • [32] Flow-injection photometric determination of copper(II) microconcentrations in natural waters
    Mozzhukhin, A. V.
    Moskvin, A. L.
    Khudyakov, Yu. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (03) : 228 - 232
  • [33] A green analytical procedure for flow-injection determination of nitrate in natural waters
    Melchert, WR
    Rocha, FRP
    TALANTA, 2005, 65 (02) : 461 - 465
  • [34] FLOW-INJECTION ULTRAVIOLET SPECTROPHOTOMETRIC DETERMINATION OF SULFATE IN NATURAL-WATERS
    KOJLO, A
    MICHALOWSKI, J
    TROJANOWICZ, M
    ANALYTICA CHIMICA ACTA, 1990, 228 (02) : 287 - 292
  • [35] Flow-injection photometric determination of copper(II) microconcentrations in natural waters
    A. V. Mozzhukhin
    A. L. Moskvin
    Yu. S. Khudyakov
    Journal of Analytical Chemistry, 2013, 68 : 228 - 232
  • [36] Chemiluminescence determination of carbofuran at trace levels in lettuce and waters by flow-injection analysis
    Huertas-Pérez, JF
    Gámiz-Gracia, L
    García-Campaña, AM
    González-Casado, A
    Vidal, JLM
    TALANTA, 2005, 65 (04) : 980 - 985
  • [37] CATALYTIC-POTENTIOMETRIC TRACE DETERMINATION OF MOLYBDENUM AND TUNGSTEN UNDER FLOW-INJECTION CONDITIONS
    MULLER, H
    SEUPEL, J
    ZEITSCHRIFT FUR CHEMIE, 1982, 22 (02): : 71 - 71
  • [38] A flow-injection electronic tongue based on potentiometric sensors for the determination of nitrate in the presence of chloride
    Gallardo, J
    Alegret, S
    del Valle, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2): : 72 - 80
  • [39] Separation of matrix by means of biosorption for flow-injection chemiluminescent determination of trace amounts of Pt(IV) in natural waters
    Godlewska-Zylkiewicz, Beata
    Malejko, Julita
    Halaburda, Piotr
    Lesniewska, Barbara
    Kojlo, Anatol
    MICROCHEMICAL JOURNAL, 2007, 85 (02) : 314 - 320
  • [40] INDIRECT POTENTIOMETRIC DETERMINATION OF METAL-IONS BY FLOW-INJECTION ANALYSIS WITH A COPPER ELECTRODE
    ALEXANDER, PW
    TROJANOWICZ, M
    HADDAD, PR
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (04): : 309 - 320