Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography

被引:0
|
作者
Matthieu J. C. M. Rutten
James M. P. Collins
Bas J. Maresch
Jacques H. J. M. Smeets
Caroline M. M. Janssen
Lambertus A. L. M. Kiemeney
Gerrit J. Jager
机构
[1] Jeroen Bosch Hospital,Department of Radiology
[2] Medical Centre Leeuwarden,Department of Radiology
[3] Hospital Gelderse Vallei,Department of Radiology
[4] Slingeland Hospital,Department of Radiology
[5] Radboud University Nijmegen Medical Centre,Department of Epidemiology and Biostatistics
来源
European Radiology | 2009年 / 19卷
关键词
Ultrasound; Fluoroscopy; Shoulder; Image-guided injection; MR arthrography;
D O I
暂无
中图分类号
学科分类号
摘要
To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and posterior approach (USp), fluoroscopic-guided anterior (FLa) and posterior (FLp) approach were used. Number of injection attempts, effect of contrast leakage on diagnostic quality, and total room, radiologist and procedure times were measured. Pain was documented with a visual analogue scale (VAS) pain score. Access to the joint was achieved in all patients. A successful first attempt significantly occurred more often with US (94%) than with fluoroscopic guidance (72%). Leakage of contrast medium did not cause interpretative difficulties. With US guidance mean room, procedure and radiologist times were significantly shorter (p < 0.001). The USa approach was rated with the lowest pre- and post-injection VAS scores. The four image-guided injection techniques are successful in injection of contrast material into the glenohumeral joint. US-guided injections and especially the anterior approach are significantly less time consuming, more successful on the first attempt, cause less patient discomfort and obviate the need for radiation and iodine contrast.
引用
收藏
页码:722 / 730
页数:8
相关论文
共 50 条
  • [31] Ultrasound-Guided Injection Techniques for the Low Back and Hip Joint
    Chen, Carl P. C.
    Lew, Henry L.
    Tsai, Wen-Chung
    Hung, Yu-Ting
    Hsu, Chih-Chin
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2011, 90 (10) : 860 - 867
  • [32] Anterior labroligamentous structures of the glenohumeral joint: Correlation of MR arthrography and anatomic dissection in cadavers
    Yen, LR
    Kwak, S
    Kim, YS
    Pedowitz, R
    Trudell, D
    Muhle, C
    Resnick, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) : 1229 - 1236
  • [33] ARTHROGRAPHY .1. A COMPARATIVE STUDY OF ARTHROGRAPHY OF THE KNEE JOINT
    HAUCH, PP
    BRITISH JOURNAL OF RADIOLOGY, 1952, 25 (291): : 120 - 129
  • [34] MR arthrography of the posterior labrocapsular complex: Relationship with glenohumeral joint alignment and clinical posterior instability
    Tung, GA
    Hou, DD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) : 369 - 375
  • [35] Magnetic Resonance Arthrography of the Glenohumeral Joint: Ultrasonography-Guided Technique Using a Posterior Approach
    Ogul, Hayri
    Bayraktutan, Ummugulsum
    Yildirim, Omer Selim
    Suma, Selami
    Ozgokce, Mesut
    Okur, Adnan
    Kantarci, Mecit
    EURASIAN JOURNAL OF MEDICINE, 2012, 44 (02): : 73 - 78
  • [36] Radiologic Analysis and Clinical Study of the Upper One-third Joint Technique for Fluoroscopically Guided Sacroiliac Joint Injection
    Park, Junghyun
    Park, Hue Jung
    Moon, Dong Eon
    Sa, Gye Jeol
    Kim, Young Hoon
    PAIN PHYSICIAN, 2015, 18 (05) : 495 - 503
  • [37] Transverse morphology of the sacroiliac joint: effect of angulation and implications for fluoroscopically guided sacroiliac joint injection
    Ling, Bernice C.
    Lee, Jeffrey W.
    Man, H. S. Jeffrey
    Jhangri, Gian S.
    Grace, Michael G. A.
    Lambert, Robert G. W.
    SKELETAL RADIOLOGY, 2006, 35 (11) : 838 - 846
  • [38] Prospective evaluation of two different injection techniques for MR arthrography of the hip
    Sylvain R. Duc
    Juerg Hodler
    Marius R. Schmid
    Marco Zanetti
    Bernard Mengiardi
    Claudio Dora
    Christian W. A. Pfirrmann
    European Radiology, 2006, 16 : 473 - 478
  • [39] MR arthrography of the shoulder: tolerance evaluation of four different injection techniques
    Perdikakis, Evangelos
    Drakonaki, Eleni
    Maris, Thomas
    Karantanas, Apostolos
    SKELETAL RADIOLOGY, 2013, 42 (01) : 99 - 105
  • [40] MR arthrography of the shoulder: tolerance evaluation of four different injection techniques
    Evangelos Perdikakis
    Eleni Drakonaki
    Thomas Maris
    Apostolos Karantanas
    Skeletal Radiology, 2013, 42 : 99 - 105