Coronary artery bypass grafting and perioperative stroke: imaging of atherosclerotic plaques in the ascending aorta with ungated high-pitch CT-angiography

被引:0
|
作者
Ulrika Asenbaum
Richard Nolz
Stefan B. Puchner
Tobias Schoster
Lukas Baumann
Julia Furtner
Daniel Zimpfer
Guenther Laufer
Christian Loewe
Sigrid E. Sandner
机构
[1] Medical University of Vienna,Department of Biomedical Imaging and Image
[2] Vienna General Hospital,Guided Therapy
[3] Medical University of Vienna,Center of Medical Statistics, Informatics, and Intelligent Systems (CEMSIIS)
[4] Medical University of Vienna,Division of Cardiac Surgery
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Perioperative stroke is a devastating complication after coronary artery bypass graft (CABG) surgery, with atherosclerosis of the ascending aorta as important risk factor. During surgical manipulation, detachment of plaques can lead to consecutive embolization into brain-supplying arteries. High-pitch computed tomography angiography (HP-CTA) represents a non-invasive imaging modality, which provides the opportunity for comprehensive imaging of the ascending aorta, including plaque detection and advanced characterization. In our present retrospective study on 719 individuals, who had undergone HP-CTA within 6 months prior to CABG, atherosclerotic disease of the ascending aorta was evaluated with respect to perioperative stroke rates. For image analysis, the ascending aorta was divided into a proximal and distal part, consisting of four segments, and evaluated for presence and distribution of calcified and mixed plaques. All patients with perioperative stroke presented with atherosclerotic disease of the ascending aorta. The stroke rate was significantly associated with the presence and extent of atherosclerotic disease. Patients burdened with mixed plaques presented with significantly higher perioperative stroke rates. This study demonstrates that HP-CTA allows accurate evaluation of plaque extent and composition in the ascending aorta, and therefore may improve risk stratification of stroke prior to CABG.
引用
收藏
相关论文
共 22 条
  • [21] Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode
    Florian Wolf
    Sebastian Leschka
    Christian Loewe
    Peter Homolka
    Christina Plank
    Ruediger Schernthaner
    Dominik Bercaczy
    Robert Goetti
    Johannes Lammer
    Guy Friedrich
    Borut Marincek
    Hatem Alkadhi
    Gudrun Feuchtner
    European Radiology, 2010, 20 : 2084 - 2091
  • [22] Feasibility and Diagnostic Accuracy for Assessment of Coronary Artery Stenosis of Prospectively Electrocardiogram-gated High-pitch Spiral Acquisition Mode Dual-source CT Coronary Angiography in Patients with Relatively Higher Heart Rates: in Comparison wit
    Kai Sun
    Rui-juan Han
    Li-fang Cui
    Rui-ping Zhao
    Li-jun Ma
    Li-jun Wang
    Li-gang Li
    Chang-yong Li
    Chinese Medical Sciences Journal, 2012, 27 (04) : 213 - 219