Ion chromatographic determination of iodide in urine and serum using a tubular ion-selective electrode based on a homogeneous crystalline membrane

被引:0
|
作者
Agostinho A. Almeida
Xiao Jun
José L. F. C. Lima
机构
[1] Universidade do Porto,CEQUP/Departamento de Química
来源
Microchimica Acta | 1997年 / 127卷
关键词
iodide; ion chromatography; tubular potentiometric detector; urine; serum;
D O I
暂无
中图分类号
学科分类号
摘要
The use of a laboratory-made iodide ion-selective electrode with tubular configuration and based on a crystalline membrane (AgI/Ag2S) as the detector for ion chromatographic determination of iodide in urine and serum is described. A CIS reversed-phase column was coated withN-cetylpyridinium chloride to prepare a low-exchange-capacity analytical column and with hexadecyltrimethylammonium bromide to prepare a concentrator pre-column. A 2.0 ml min−1 flow rate of deionized water and 0.1 mol 1−1 KNO3 solution was used for the pre-concentration and for the chromatographic separation, respectively. For optimum performance of the detector a background level of iodide was added into the column effluent. A linear relationship (r = 0.9997) between tubular electrode potential (as peak height) and iodide concentration in the range 5–400 μg 1−1 and a detection limit of 1.47 μg 1−1 were obtained. The method shows good reproducibility for both peak height (2.2% RSD) and retention time (1.3% RSD). Recoveries on its application to the samples were 93.0–100.9% for urine and 91.4–106.0% for serum.
引用
收藏
页码:55 / 60
页数:5
相关论文
共 50 条
  • [31] Using of hydrogen ion-selective poly(vinyl chloride) membrane electrode based on calix[4]arene as thiocyanate ion-selective electrode
    Erden, S
    Demirel, A
    Memon, S
    Yilmaz, M
    Canel, E
    Kiliç, E
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) : 290 - 296
  • [32] ION-SELECTIVE ELECTRODE FOR PROCAINAMIDE DETERMINATION IN BLOOD-SERUM
    KATSU, T
    FURUNO, K
    YAMASHITA, S
    GOMITA, Y
    [J]. ANALYTICA CHIMICA ACTA, 1995, 312 (01) : 35 - 38
  • [33] Ion-selective electrode with a pseudoliquid membrane phase for determination of cefuroxime
    Dumkiewicz, R
    Wardak, C
    Pokrzywa, K
    [J]. CHEMIA ANALITYCZNA, 1999, 44 (05): : 857 - 864
  • [34] DETERMINATION OF SOLUBILITY PRODUCT CONSTANTS USING AN ION-SELECTIVE ELECTRODE BASED ON FLUORIDE DOUBLE MEMBRANE
    ARA, RCD
    PASCUAL, PC
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1993, 32 (10): : 903 - 904
  • [35] NEW PLASTIC MEMBRANE ION-SELECTIVE ELECTRODE FOR DETERMINATION OF TRIMETHOPRIM
    ABOUDAN, M
    ISSA, YM
    SHOUKRY, AF
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1994, 61 (01) : 31 - 35
  • [36] DETERMINATION OF BROMIDE INDEX IN MUCOVISCIDOSIS WITH ION-SELECTIVE MEMBRANE ELECTRODE
    GYURKOVITS, K
    LASZLO, A
    [J]. ACTA PAEDIATRICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1974, 15 (01): : 49 - 52
  • [37] DETERMINATION OF FLUORIDE IN TOOTHPASTE USING AN ION-SELECTIVE ELECTRODE
    LIGHT, TS
    CAPPUCCINO, CC
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1975, 52 (04) : 247 - 250
  • [38] DETERMINATION OF TRIMECAINE AND LIDOCAINE USING AN ION-SELECTIVE ELECTRODE
    KEREICHUK, AS
    PANTSURKIN, VI
    PTUKHA, EV
    POTEMKIN, KD
    CHEKRYSHKINA, LA
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1990, 45 (03): : 409 - 413
  • [39] Ion-Selective Electrode for the Determination of Sulfadimezine
    S. V. Kharitonov
    [J]. Journal of Analytical Chemistry, 2001, 56 : 671 - 675
  • [40] Ion-selective electrode for piperazine determination
    Kharitonov S.V.
    Gorelov I.P.
    Davydova I.G.
    [J]. Pharmaceutical Chemistry Journal, 2001, 35 (4) : 226 - 228