Reproducibility of ultrasound-guided attenuation parameter (UGAP) to the noninvasive evaluation of hepatic steatosis

被引:0
|
作者
Yanan Zhao
Minyue Jia
Chao Zhang
Xinxu Feng
Jifan Chen
Qunying Li
Yingying Zhang
Wen Xu
Yiping Dong
Yifan Jiang
Yajing Liu
Pintong Huang
机构
[1] The Second Affiliated Hospital of Zhejiang University School of Medicine,Department of Ultrasound Medicine
[2] t,Department of Ultrasound Medicine
[3] The Second Affiliated Hospital of Soochow University,undefined
[4] GE Healthcare Clinical Education Team,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to identify the applicability of an ultrasound-guided attenuation parameter (UGAP) for the noninvasive assessment of hepatic steatosis in clinical practice and to compare its correlation with B-mode ultrasound (US). From May to July 2021, 63 subjects with different body mass index (BMI) grades were included in the prospective study. All of them performed UGAP measurements, under different breathing manipulations, positions, diet statuses, and operators. After that, the UGAP values were compared with the visual grades of hepatic steatosis on B-mode US using a 4-point scale method. The intraclass correlation (ICC) of the UGAP values between the two radiologists was 0.862 (p < 0.001), and the ICCs of the UGAP values on the same day and different days by radiologist A were 0.899 (p < 0.001) and 0.910 (p < 0.001), respectively. There were no significant differences in UGAP values under different breathing manipulations (p > 0.05), positions (p > 0.05), or diet statuses (p = 0.300). The UGAP values in the fasting (supine position, segment V, 1) condition among the lean (BMI < 24 kg/m2), overweight (24 kg/m2 ≤ BMI < 28 kg/m2) and obese groups (BMI ≥ 28 kg/m2) were 0.60 ± 0.12, 0.66 ± 0.14, and 0.71 ± 0.11 dB/cm/MHz, respectively, with a significant difference (p = 0.006). The correlation coefficients (Rho) between the UGAP values and the visual grades of hepatic steatosis by the two reviewers were 0.845 (p < 0.001) and 0.850 (p < 0.001), corresponding to a strong relationship. Steatosis grades by reviewer 1 (p = 0.036) and reviewer 2 (p = 0.003) were significant factors determining the UGAP values according to the multivariate linear regression analysis. UGAP demonstrated excellent intraobserver and interobserver reproducibility in the assessment of hepatic steatosis. UGAP may be a promising tool in clinical practice to predict hepatic steatosis.
引用
收藏
相关论文
共 50 条
  • [1] Reproducibility of ultrasound-guided attenuation parameter (UGAP) to the noninvasive evaluation of hepatic steatosis
    Zhao, Yanan
    Jia, Minyue
    Zhang, Chao
    Feng, Xinxu
    Chen, Jifan
    Li, Qunying
    Zhang, Yingying
    Xu, Wen
    Dong, Yiping
    Liu, Yajing
    Jiang, Yifan
    Huang, Pintong
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] Reproducibility of ultrasound attenuation imaging for the noninvasive evaluation of hepatic steatosis
    Yoo, Jeongin
    Lee, Jeong Min
    Joo, Ijin
    Lee, Dong Ho
    Yoon, Jeong Hee
    Kang, Hyo-Jin
    Ahn, Su Joa
    ULTRASONOGRAPHY, 2020, 39 (02) : 121 - 129
  • [3] ULTRASOUND-GUIDED ATTENUATION PARAMETER (UGAP) FOR THE QUANTIFICATION OF LIVER STEATOSIS USING CONTROLLED ATTENUATION PARAMETER (CAP) AS THE REFERENCE METHOD
    Bende, Felix
    Sporea, Ioan
    Baldea, Victor
    Lazar, Alin
    Lupusoru, Raluca
    Fofiu, Renata
    Popescu, Alina
    Sirli, Roxana
    GASTROENTEROLOGY, 2020, 158 (06) : S1411 - S1411
  • [4] Ultrasound-Guided Attenuation Parameter (UGAP) for the quantification of liver steatosis using the Controlled Attenuation Parameter (CAP) as the reference method
    Bende, Felix
    Sporea, Ioan
    Sirli, Roxana
    Baldea, Victor
    Lazar, Alin
    Lupusoru, Raluca
    Fofiu, Renata
    Popescu, Alina
    MEDICAL ULTRASONOGRAPHY, 2021, 23 (01) : 7 - 14
  • [5] Accuracy of Ultrasound-Guided Attenuation Parameter for Diagnosing Hepatic Steatosis
    Yagobian, Shiva D.
    Dasyam, Navya
    Minervini, Marta
    Tublin, Mitchell
    Behari, Jaideep
    Furlan, Alessandro
    ULTRASOUND QUARTERLY, 2025, 41 (01)
  • [6] Reliability and stability of ultrasound-guided attenuation parameter in evaluating hepatic steatosis
    Xiaodan Zhang
    Liping Luo
    Huahui Liu
    Shuang Liang
    Erjiao Xu
    Journal of Ultrasound, 2024, 27 : 145 - 152
  • [7] Reliability and stability of ultrasound-guided attenuation parameter in evaluating hepatic steatosis
    Zhang, Xiaodan
    Luo, Liping
    Liu, Huahui
    Liang, Shuang
    Xu, Erjiao
    JOURNAL OF ULTRASOUND, 2024, 27 (1) : 145 - 152
  • [8] The Diagnostic Value of Ultrasound-guided Attenuation Parameter (UGAP) in metabolic fatty liver disease
    Wu H.
    Zeng Y.
    Chen F.
    Peng J.
    Chen L.
    Current Medical Imaging, 2024, 20
  • [9] Utility of Ultrasound-Guided Attenuation Parameter (UGAP) in Renal Angiomyolipoma (AML): First Results
    Kranert, Paul Christian
    Kranert, Paula
    Banas, Miriam C.
    Jung, Ernst Michael
    Banas, Bernhard
    Putz, Franz Josef
    DIAGNOSTICS, 2024, 14 (18)
  • [10] Liver stiffness does not affect ultrasound-guided attenuation coefficient measurement in the evaluation of hepatic steatosis
    Tada, Toshifumi
    Kumada, Takashi
    Toyoda, Hidenori
    Yasuda, Satoshi
    Sone, Yasuhiro
    Hashinokuchi, Shinichi
    Ogawa, Sadanobu
    Oguri, Takuma
    Kamiyama, Naohisa
    Chuma, Makoto
    Akita, Tomoyuki
    Tanaka, Junko