Validation of image registration and fusion of MV CBCT and planning CT for radiotherapy treatment planning

被引:0
|
作者
T. Hannah Mary Thomas
D. Devakumar
S. Balukrishna
Henry Finlay Godson
B. Paul Ravindran
机构
[1] Christian Medical College,Department of Bioengineering
[2] Christian Medical College,Department of Nuclear Medicine
[3] Christian Medical College,Department of Radiotherapy
关键词
Megavoltage cone beam CT; Registration; Planning CT; Fusion; Validation;
D O I
暂无
中图分类号
学科分类号
摘要
In areas like adaptive therapy, multi-phase radiotherapy, and single fraction palliative treatment or in the treatment of patients with metal implants where megavoltage(MV) CT could be considered as a treatment planning modality, the reduced contrast in the MV CT images could lead to limited accuracy in localization of the structures. This would affect the precision of the treatment. In this study, as an extension our previous work on bespoke MV cone beam CT (MV CBCT), we propose to register the MV CBCT with kilovoltage (kV) CT for treatment planning. The MV CBCT images registered with kV CT would be effective for treatment planning as it would account for the inadequate soft tissue information in the MV CBCT and would allow comparison of changes in patient dimensions and assist in localization of the structures. The intensity based registration algorithm of the BrainSCAN therapy planning software was used for image registration of the MV CBCT and kV CT images. The accuracy of the registration was validated using qualitative and quantitative measures. The effect of image quality on the level of agreement between the contouring done on both the MV CBCT and kV CT was assessed by comparing the volumes of six structures delineated. To assess the level of agreement between the plans after the registration, two independent plans were generated on the MV CBCT and the planning CT using the posterior fossa of the skull as the target. The dose volume histograms and conformity indices of the plans were compared. The results of this study show that treatment planning with MV CBCT images would be effective, using additional anatomical structure information derived from registering the MV CBCT image with a standard kVCT.
引用
收藏
页码:441 / 447
页数:6
相关论文
共 50 条
  • [11] IMAGE FUSION FOR STEREOTAXIC RADIOTHERAPY AND RADIOSURGERY TREATMENT PLANNING
    KOOY, HM
    VANHERK, M
    BARNES, PD
    ALEXANDER, E
    DUNBAR, SF
    TARBELL, NJ
    MULKERN, RV
    HOLUPKA, EJ
    LOEFFLER, JS
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1229 - 1234
  • [12] Evaluating commercial image registration packages for radiotherapy treatment planning
    Dalah, Entesar Z.
    Nisbet, A.
    Reise, S.
    Bradley, D.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (12) : 1948 - 1953
  • [13] Computed Tomography/Magnetic Resonance Imaging (CT/MRI) Image Registration and Fusion Assessment for Accurate Glioblastoma Radiotherapy Treatment Planning
    Touabti, Khalil Mohamed Mokhtar
    Kharfi, Faycal
    Benkahila, Karim
    Merouane, Sid-Ali
    INTERNATIONAL JOURNAL OF CANCER MANAGEMENT, 2020, 13 (09) : 1 - 8
  • [14] Assessment of the use of synthetic CT produced by deformable image registration of planning CT and CBCT in adaptive radiotherapy treatments of head and neck cancers
    Sanju
    Mukherji, Ashutosh
    Nanda, Sambit S.
    Dokania, Shubham
    Kataria, Alka
    Kumar, Narender
    Saini, Vinay
    Barman, Sanjay
    Epili, Dandpani R.
    Choubey, Ajay
    Patil, Ninad H.
    Krishnan, Ajay
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2025, 131
  • [15] Rapid Multimodal Medical Image Registration and Fusion in 3D conformal radiotherapy treatment planning
    Li, Bin
    Tian, Lianfang
    Ou, Shanxing
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [16] Rapid multimodal medical image registration and fusion in 3D conformai radiotherapy treatment planning
    Li, Bin
    Ou, Shanxing
    Tian, Lianfang
    HKIE Transactions Hong Kong Institution of Engineers, 2010, 17 (03): : 34 - 44
  • [17] Nonrigid registration of multitemporal CT and MR images for radiotherapy treatment planning
    Slagmolen, Pieter
    Loeckx, Dirk
    Roels, Sarah
    Geets, Xavier
    Maes, Frederik
    Haustermans, Karin
    Suetens, Paul
    BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS, 2006, 4057 : 297 - 305
  • [18] Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning system
    Velec, Michael
    Moseley, Joanne L.
    Svensson, Stina
    Hardemark, Bjorn
    Jaffray, David A.
    Brock, Kristy K.
    MEDICAL PHYSICS, 2017, 44 (07) : 3407 - 3417
  • [19] Feasibility of hyperpolarised 3-helium MRI and CT image registration for NSCLC radiotherapy treatment planning
    Ireland, R
    McJury, M
    van Beek, E
    Woodhouse, N
    Wild, J
    Hatton, M
    Fisher, P
    LUNG CANCER, 2005, 49 : S308 - S308
  • [20] QA of dose originating from deformable image registration of planning CT to CBCT on the Ethos system
    Sjolin, M.
    Vogelius, I. R.
    Jensen, N. K. G.
    Bak, M. E.
    Kjaer-Kristoffersen, F.
    Nottrup, T. J.
    Friborg, J.
    Hansen, V. N.
    Petersen, J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1427 - S1429