Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System

被引:0
|
作者
Selim Bozkurt
Frans N. van de Vosse
Marcel C. M. Rutten
机构
[1] Eindhoven University of Technology,Department of Biomedical Engineering
关键词
Continuous-flow left ventricular assist device (CF-LVAD); Arterial pulsatility; In vitro experiment;
D O I
暂无
中图分类号
学科分类号
摘要
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.
引用
收藏
页码:308 / 315
页数:7
相关论文
共 50 条
  • [41] A Mock Circulatory System to Assess the Performance of Continuous-Flow Left Ventricular Assist Devices (LVADs): Does Axial Flow Unload Better Than Centrifugal LVAD?
    Senage, Thomas
    Fevrier, Dorothee
    Michel, Magali
    Pichot, Emmanuel
    Duveau, Daniel
    Tsui, Steven
    Trochu, Jean Noel
    Roussel, Jean Christian
    ASAIO JOURNAL, 2014, 60 (02) : 140 - 147
  • [42] Accuracy of Doppler blood pressure measurement in continuous-flow left ventricular assist device patients
    Li, Song
    Beckman, Jennifer A.
    Welch, Nathan G.
    Bjelkengren, Jason
    Masri, Sofia Carolina
    Minami, Elina
    Stempien-Otero, April
    Levy, Wayne C.
    O'Brien, Kevin D.
    Lin, Shin
    Farris, Stephen D.
    Chen, Richard K.
    Wood, Gregory
    Koomalsingh, Kevin
    Kirkpatrick, James
    McCabe, James
    Leary, Peter J.
    Chassagne, Fanette
    Chivukula, Venkat Keshav
    Aliseda, Alberto
    Mahr, Claudius
    ESC HEART FAILURE, 2019, 6 (04): : 793 - 798
  • [43] Preservation of arterial pulsatility to prevent acquired von willebrand disease with continuous-flow left ventricular assist device: insights from a pig model
    Vincent, F.
    Rauch, A.
    Nix, C.
    Siess, T.
    Schurtz, G.
    Rousse, N.
    Delhaye, C.
    Moussa, M.
    Lemesle, G.
    Loobuyck, V.
    Staels, B.
    Vincentelli, A.
    Lenting, P. J.
    Susen, S.
    Van Belle, E.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1207 - 1208
  • [44] Creating adequate pulsatility with a continuous flow left ventricular assist device: just do it!
    Patel, Snehal R.
    Jorde, Ulrich P.
    CURRENT OPINION IN CARDIOLOGY, 2016, 31 (03) : 329 - 336
  • [45] Designing an Active Valvulated Outflow Conduit for a Continuous-Flow Left Ventricular Assist Device to Increase Pulsatility: A Simulation Study
    Cusimano, Valerio
    di Molfetta, Arianna
    Ferrari, Gianfranco
    ASAIO JOURNAL, 2021, 67 (05) : 529 - 535
  • [46] Further Peripheral Vascular Dysfunction in Heart Failure Patients With a Continuous-Flow Left Ventricular Assist Device The Role of Pulsatility
    Witman, Melissa A. H.
    Garten, Ryan S.
    Gifford, Jayson R.
    Groot, H. Jonathan
    Trinity, Joel D.
    Stehlik, Josef
    Nativi, Jose N.
    Selzman, Craig H.
    Drakos, Stavros G.
    Richardson, Russell S.
    JACC-HEART FAILURE, 2015, 3 (09) : 703 - 711
  • [47] Comparing Velocity and Mean Arterial Pressure to Assess Pulsatility in Patients with Continuous Flow Left Ventricular Assist Devices
    Emmanuel, S.
    Adji, A.
    Jansz, P.
    Hayward, C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S356 - S356
  • [48] Coronary arterial function is not impaired in patients following continuous-flow left ventricular assist device implantation
    Johnson, Elizabeth
    Diakos, Nikos
    Selzman, Craig
    Reid, Bruce
    Stehlik, Josef
    Kfoury, Abdallah
    Saidi, Abdulfatah
    Wever-Pinzon, Omar
    Verma, Divya R.
    Yen, Chi-Gang
    Li, Dean
    Drakos, Stavros
    Symons, J. David
    FASEB JOURNAL, 2013, 27
  • [49] Pulsatile operation of a continuous-flow right ventricular assist device (RVAD) to improve vascular pulsatility
    Ng, Boon C.
    Kleinheyer, Matthias
    Smith, Peter A.
    Timms, Daniel
    Cohn, William E.
    Lim, Einly
    PLOS ONE, 2018, 13 (04):
  • [50] Implication to ventricular arrhythmia during continuous-flow left ventricular assist device supports
    Kataoka, Naoya
    Imamura, Teruhiko
    ARTIFICIAL ORGANS, 2023, 47 (06) : 1059 - 1060