Electrochemical determination of amlodipine using a CuO-NiO nanocomposite/ionic liquid modified carbon paste electrode as an electrochemical sensor

被引:0
|
作者
Mahzad Firouzi
Masoud Giahi
Mostafa Najafi
Seyed Saied Homami
Seyed Husain Hashemi Mousavi
机构
[1] Islamic Azad University,Department of Chemistry, South Tehran Branch
[2] Imam Hossein University,Department of Chemistry, Faculty of Science
来源
关键词
Amlodipine; Ionic liquid; BMIM-PF; Voltammetry; CuO-NiO; Nanocomposite; CuO-NiO/IL/CPE; Pharmacokinetic study; Electrocatalytic behavior;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, a nanocomposite of CuO-NiO was synthesized by sol-gel method. Its structure and morphology were characterized by X-ray diffraction, field emission scanning electron microscopy (FESEM), and energy-dispersive X-ray spectroscopy techniques. The FESEM image showed particles with the size at about 30–80 nm in diameters. In continue, a carbon paste (CP) modified electrode with CuO-NiO nanocomposite and an ionic liquid ((1-butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6)) (CuO-NiO/IL/CPE) was fabricated as an electrochemical sensor for determination of amlodipine (AML). The cyclic and differential pulse voltammetry, electrochemical impedance spectroscopy, and chronoamperometry were used for electrochemical studies and AML determination. The CuO-NiO/IL/CPE indicated a good electrocatalytic behavior towards to oxidation of AML. The anodic peak currents were increased with the AML concentration and indicated a linear dynamic range from 0.1 to 100 μM and a detection limit of 0.06 μM (S/N = 5) under the optimized conditions. The introduced electrochemical sensor was utilized for the determination of AML in the pharmaceutical formulations, human urine, and blood plasma samples.
引用
收藏
相关论文
共 50 条
  • [41] An Electrochemical Sensor based on Reduced Graphene oxide-Silver Nanocomposite Modified Carbon Paste Electrode for Acetaminophen Determination
    Tavakolian, Ebrahim
    Tashkhourian, Javad
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (02): : 219 - 233
  • [42] An electrochemical sensor based on a carbon paste electrode for the determination of buserelin
    Fallah, Marjan
    Rahimnejad, Mostafa
    Asghary, Maryam
    Mashkour, Mehrdad
    [J]. ANALYTICAL METHODS, 2020, 12 (01) : 33 - 38
  • [43] Selective Electrochemical Determination of Desipramine Using a Lipid Modified Carbon Paste Electrode
    Khodari, Mahmoud
    [J]. XXXV MODERNI ELEKTROCHEMICKE METODY, 2015, : 100 - 103
  • [44] Sensitive Electrochemical Determination of Catechol with a Graphene Modified Carbon Ionic Liquid Electrode
    Ruan, Chengxiang
    Li, Tongtong
    Wang, Xiuzheng
    Qi, Xiaowei
    Lou, Jin
    Gao, Weimin
    Sun, Wei
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (12) : 1584 - 1590
  • [45] Electrochemical Detection of Hydrazine by Carbon Paste Electrode Modified with Ferrocene Derivatives, Ionic Liquid, and CoS2-Carbon Nanotube Nanocomposite
    Tajik, Somayeh
    Beitollahi, Hadi
    Hosseinzadeh, Rahman
    Afshar, Abbas Aghaei
    Varma, Rajender S.
    Jang, Ho Won
    Shokouhimehr, Mohammadreza
    [J]. ACS OMEGA, 2021, 6 (07): : 4641 - 4648
  • [46] The first electrochemical sensor for determination of mangiferin based on an ionic liquid–graphene nanosheets paste electrode
    Somayeh Tajik
    Mohammad Ali Taher
    Hadi Beitollahi
    [J]. Ionics, 2014, 20 : 1155 - 1161
  • [47] Copper oxide, ionic liquid and Mn(III) Salen modified carbon paste electrode as selective electrochemical sensor for determination of droxidopa in the presence of carbidopa
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Shoaie, Iran Sheikh
    Sheikhshoaie, Mahdieh
    Beitollahi, Hadi
    [J]. EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (03): : 387 - 397
  • [48] Electrochemical sensor for simultaneous determination of dextromethorphan hydrobromide and paracetamol at carbon paste electrode modified with synthesized indium tin oxide nanoparticles and ionic liquid
    Kingsley, Mal Phebe
    Sathe, Pratima Ashok
    Srivastava, Ashwini K.
    [J]. JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2017, 94 (07) : 681 - 698
  • [49] Electrochemical Determination of Myristicin Using a Carbon Paste Electrode
    Rosecka, Kamila
    Mikysek, Tomas
    Svancara, Ivan
    [J]. XXXIV. MODERNI ELEKTROCHEMICKE METODY, 2014, : 153 - 156
  • [50] Electrochemical Sensor for Therapeutic Monitoring of Ganciclovir in Spiked Plasma Samples Using a Carbon Paste Electrode Modified with CuO nanoparticles
    Hesham, Nada
    Mahmoud, Amr M.
    Hegazy, Maha A.
    Wagdy, Hebatallah A.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (03)