Cost-benefit analysis of intraoperative 3D imaging [Kosten- und nutzenanalyse der intraoperativen 3D-bildgebung]

被引:0
|
作者
Hüfner T. [1 ,2 ]
Stübig T. [1 ]
Gösling T. [1 ]
Kendoff D. [1 ]
Geerling J. [1 ]
Krettek C. [1 ]
机构
[1] Unfallchirurgische Klinik, Medizinische Hochschule, Hannover
[2] Unfallchirurgische Klinik, Medizinische Hochschule, 30625 Hannover
来源
Der Unfallchirurg | 2007年 / 110卷 / 1期
关键词
Cost analysis; Costs per minute; Intraoperative 3D imaging; Iso-C[!sup]3D[!/sup;
D O I
10.1007/s00113-006-1202-6
中图分类号
学科分类号
摘要
Background. With intraoperative 3D imaging, inevitable corrections may be done already during the operation, and a second procedure can be avoided. The purpose of this study was to perform a cost-benefit analysis during the first year of intraoperative 3D application in order to provide a cost transparency for the surgeon within the current DRG system. Methods. On the basis of internal data and the literature, the annual operating costs of the ISO-C3D were calculated at 27,940 euros (purchase price, depreciation, maintenance, repair), the costs of an average revision as a secondary operation at 2,385 euros (costs avoided with the ISO-C3D, Siremobil, Siemens, Erlangen, Germany), and the dynamic costs of an intraoperative 3D scan were averaged to 131.08 euros (draping, additional time, personnel). Results. In the year 2003 intraoperative 3D scanning was done in 126 patients, and intraoperative revision was performed in 24 (19%) due to the additional intraoperative 3D information provided by the Siremobil. In 11 (8.7%) patients the implant position was corrected and in 13 (10.3%) patients the reduction was improved. Taking only fixed costs into consideration, 29,311.52 euros could be saved, and when fixed and dynamic costs are taken into account 12,795.44 euros could be saved. Since the parameters for each hospital are different, the following formula for an individual computation is suitable. For the calculation of the cost the following mathematical relationship results: (annual fixed costs) + (costs per scan × number of cases) - (revision costs × revision rate [p]) × number of cases [N]) = 0. Discussion. Although the costs of an ISO-C3D are considerably high, an economic benefit can also accrue with frequent application and high rates of avoided revision. However, if the rate of avoided revision adds up to only 5%, a substantial deficit may result. © 2006 Springer Medizin Verlag.
引用
收藏
页码:14 / 21
页数:7
相关论文
共 50 条
  • [31] Intraoperative 3D imaging. Diagnostic accuracy and therapeutic benefits
    Stengel, D.
    Wich, M.
    Ekkernkamp, A.
    Spranger, N.
    [J]. UNFALLCHIRURG, 2016, 119 (10): : 835 - 842
  • [32] 3D imaging for bite mark analysis
    Evans, S. T.
    Jones, C.
    Plassmann, P.
    [J]. IMAGING SCIENCE JOURNAL, 2013, 61 (04): : 351 - 360
  • [33] Analysis of a 3D Microwave Imaging System
    Asefi, Mohammad
    Ostadrahimi, Majid
    LoVetri, Joe
    Shafai, Lotfollah
    [J]. 2013 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2013, : 608 - 609
  • [34] INNOVATIVE USES OF REAL-TIME INTRAOPERATIVE 3D IMAGING
    Plantak, M.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2018, 66 (01) : 156 - 156
  • [35] Intraoperative 3D imaging in plate osteosynthesis of proximal humerus fractures
    Alexander Böhringer
    Raffael Cintean
    Alexander Eickhoff
    Florian Gebhard
    Konrad Schütze
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4993 - 5000
  • [36] Intraoperative 3D imaging in plate osteosynthesis of proximal humerus fractures
    Boehringer, Alexander
    Cintean, Raffael
    Eickhoff, Alexander
    Gebhard, Florian
    Schuetze, Konrad
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (08) : 4993 - 5000
  • [37] An endoscopic chisel: intraoperative imaging carves 3D anatomical models
    Mangulabnan, Jan Emily
    Soberanis-Mukul, Roger D.
    Teufel, Timo
    Sahu, Manish
    Porras, Jose L.
    Vedula, S. Swaroop
    Ishii, Masaru
    Hager, Gregory
    Taylor, Russell H.
    Unberath, Mathias
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (07) : 1359 - 1366
  • [38] CLINICAL 3D IMAGING AND ANALYSIS WITH 3DVIEWNIX
    UDUPA, JK
    SAMARASEKERA, S
    ODHNER, D
    IYER, K
    FALCAO, AX
    [J]. RADIOLOGY, 1995, 197 : 448 - 448
  • [39] 3D CHIP FOR LOW COST CELL ANALYSIS
    Mottet, Guillaume
    Perez-Toralla, Karla
    Tulukcuoglu, Ezgi
    Champ, Jerome
    Draskovic, Irena
    Descroix, Stephanie
    Malaquin, Laurent
    Viovy, Jean Louis
    [J]. CECE 2012: 9TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2012, : 96 - +
  • [40] Developing a low cost 3D imaging solution for inscribed stone surface analysis
    Spring, Adam P.
    Peters, Caradoc
    [J]. JOURNAL OF ARCHAEOLOGICAL SCIENCE, 2014, 52 : 97 - 107