Titanium coating of a polypropylene mesh for hernia repair: Effect on biocompatibilty

被引:41
|
作者
Junge K. [1 ,2 ]
Rosch R. [1 ,2 ]
Klinge U. [1 ,2 ]
Saklak M. [1 ]
Klosterhalfen B. [2 ,3 ]
Peiper C. [1 ]
Schumpelick V. [1 ]
机构
[1] Department of Surgery, Technical University of Aachen, 52057 Aachen
[2] German Centre of Excellence for Biomaterial and Implant Pathology, Technical University of Aachen, 52057 Aachen
[3] Institute of Pathology, Central Hospital of Düren, Düren
关键词
Biocompatibility; Hernia; Mesh; Polypropylene; Titanium;
D O I
10.1007/s10029-004-0292-8
中图分类号
学科分类号
摘要
Titanium and its alloys are used worldwide in surgery. The favorable characteristics that make this material desirable for implantation are corrosion resistance and biocompatibility. Concerning hernia repair, a mesh modification has been developed using titanium layering of a polypropylene mesh implant, which is said to lead to an improved biocompatibility compared to commercially available mesh materials. To analyze the pure effect of titanium coating, two different mesh structures were studied using a standardized animal model. The titanium-coated monofilamentous, large porous, and lightweight mesh made of polypropylene and coated with titanium (PP+T) was compared to a pure polypropylene mesh manufactured with a similar structure and amount of material serving as a control (PP). In Sprague-Dawley rats, mesh samples were placed in a subcutaneuous position. Then 56, 84, and 182 days after mesh implantation, three animals from each group were sacrificed for morphological observations (amount of inflammatory and connective tissue formation, percentages of proliferating and apoptotic cells, percentage of macrophages). Both mesh modifications investigated showed an overall good biocompatibility. Macroscopic clinical observation after implantation of up to 182 days was uneventful. The tissue response to the PP as well as to the PP+T mesh was characterized by a moderate inflammatory tissue reaction limited to the perifilamentary region as is known for low weight, large porous, and monofilamentous mesh structures. No significant improvement of biocompatibility was found when analyzing the effect of titanium coating compared to the pure polypropylene mesh structure. © Springer-Verlag 2004.
引用
收藏
页码:115 / 119
页数:4
相关论文
共 50 条
  • [31] Parastomal hernia repair - Modified Thorlakson technique, reinforced by polypropylene mesh
    Tekkis, PP
    Kocher, HM
    Payne, JG
    DISEASES OF THE COLON & RECTUM, 1999, 42 (11) : 1505 - 1508
  • [32] Laparoscopic repair of congenital pleuroperitoneal hernia using a polypropylene mesh in a dog
    Hartmann, H. F.
    Basso, P. C.
    Faria, K. L.
    Oliveira, M. T.
    Souza, F. W.
    Garcia, E. V.
    Feranti, J. P. S.
    Silva, M. A. M.
    Brun, M. V.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2015, 67 (06) : 1547 - 1553
  • [33] The Analysis of Infection after Polypropylene Mesh Repair of Abdominal Wall Hernia
    Arnolds Jezupors
    Māris Mihelsons
    World Journal of Surgery, 2006, 30 : 2270 - 2278
  • [34] The analysis of infection after polypropylene mesh repair of abdominal wall hernia
    Jezupors, Arnolds
    Mihelsons, Maris
    WORLD JOURNAL OF SURGERY, 2006, 30 (12) : 2270 - 2278
  • [35] REPAIR OF A MASSIVE ABDOMINAL-HERNIA IN A HORSE USING POLYPROPYLENE MESH
    HILBERT, BJ
    SLATTER, DH
    MCDERMOTT, JD
    AUSTRALIAN VETERINARY JOURNAL, 1978, 54 (12) : 588 - 590
  • [36] Intraperitoneal polypropylene mesh repair of incisional hernia is not associated with enterocutaneous fistula
    Amid, PK
    BRITISH JOURNAL OF SURGERY, 2000, 87 (10) : 1436 - 1436
  • [37] Incisional hernia and its repair with polypropylene mesh in renal transplant recipients
    Mazzucchi, E
    Nahas, WC
    Antonopoulos, I
    Ianhez, LE
    Arap, S
    JOURNAL OF UROLOGY, 2001, 166 (03): : 816 - 819
  • [38] Ileocutaneous fistula formation following laparoscopic polypropylene mesh hernia repair
    Miller, K
    Junger, W
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (07): : 772 - 773
  • [39] The continuing challenge of parastomal hernia: failure of a novel polypropylene mesh repair
    Morris-Stiff, G
    Hughes, LE
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1998, 80 (03) : 184 - 187
  • [40] The continuing challenge of parastomal hernia: failure of a novel polypropylene mesh repair
    Tekkis, PP
    Kocher, HM
    Payne, JG
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1999, 81 (02) : 140 - 141