Performance investigation of a novel calorimeter for a heat pump system according to flow loops

被引:0
|
作者
Kofi Owura Amoabeng
Kwang Ho Lee
Jong Min Choi
机构
[1] Hanbat National University,Graduate School of Mechanical Engineering
[2] Korea University,Department of Architecture
[3] Hanbat National University,Department of Mechanical Engineering
关键词
Energy savings; Flow configuration; Heat pump; Novel calorimeter; Standard test conditions;
D O I
暂无
中图分类号
学科分类号
摘要
Heat pumps cover a wide range of heating and cooling applications owing to their means of drawing out heat from ground, air and water at low temperature. In order to acquire performance data for heat pump certification and rating, the calorimeter is used in measuring the heat pump. In conventional approach of measuring the heat pump with standard test conditions, a great amount of energy is used in the calorimeter for cooling and heating. Using innovative ways to enhance the calorimeter performance is significant for energy and cost savings. Therefore, a novel calorimeter was developed for heat pump measurement. Two different flow loop configurations, specified as cases (1) and (2) were adopted. In the case (1), secondary fluid flow through the heat recovery unit was directly from heat pump test unit heat exchanger while in case (2), secondary fluid flow through heat recovery unit was from constant temperature water bath directly. The energy usage of the novel calorimeter based on the impact of each configuration was analyzed. Experiments were conducted using a water-to-water heat pump unit in heating and cooling approach with variation in operating conditions. Energy analyses based on test data indicated that energy reduction of the novel calorimeter was at least 72 % for heating and 69 % for cooling in relation to energy used in conventional calorimeter. Moreover, for novel calorimeter, case (1) resulted in energy savings of at least 9.1 % for cooling and 13 % for heating in relation to case (2). However, for heat pump units with very low capacities, tests measurements were executed using case (2) configuration because the tests in case (1) resulted in large thermal fluctuations such that the steady operating conditions of the water setpoint temperatures at inlet to the indoor and outdoor heat exchangers of the test unit were unattainable.
引用
收藏
页码:1749 / 1763
页数:14
相关论文
共 50 条
  • [21] Performance investigation on an air source heat pump system with latent heat thermal energy storage
    Lin, Ying
    Fan, Yubin
    Yu, Meng
    Jiang, Long
    Zhang, Xuejun
    [J]. ENERGY, 2022, 239
  • [22] Investigation of heat pump performance in heterogeneous ground
    Boban, Luka
    Soldo, Vladimir
    Fujii, Hikari
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 211
  • [23] Theoretical and experimental investigation of a novel high temperature heat pump system for recovering heat from refrigeration system
    Zhao, Zhaorui
    Xing, Ziwen
    Hou, Feng
    Tian, Yafen
    Jiang, Shaoming
    [J]. APPLIED THERMAL ENGINEERING, 2016, 107 : 758 - 767
  • [24] A novel absorption heat pump system
    Riffat, S
    Wu, SY
    Bol, B
    [J]. ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 939 - 943
  • [25] Performance investigation of a heat pump driven, vacuum liquid desiccant regeneration system
    Liu, Jun
    Liu, Xiaohua
    Zhang, Tao
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 2435 - 2440
  • [26] Investigation of annual energy performance of a VWV air source heat pump system
    Wang, R. Z.
    Jin, Z. Q.
    Zhai, X. Q.
    Jin, C. C.
    Luo, W. L.
    Eikevik, T. M.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 85 : 383 - 394
  • [27] Experimental investigation and performance analysis of a ground-coupled heat pump system
    Zhai, X. Q.
    Yu, X.
    Yang, Y.
    Wang, R. Z.
    [J]. GEOTHERMICS, 2013, 48 : 112 - 120
  • [28] Investigation of the performance of a combined solar thermal heat pump hot water system
    Panaras, G.
    Mathioulakis, E.
    Belessiotis, V.
    [J]. SOLAR ENERGY, 2013, 93 : 169 - 182
  • [29] Performance investigation of a multi-connected heating tower heat pump system
    Hu, Han
    Ji, Jianzhou
    Xie, Lingyun
    Le, Yi
    Zhang, Xiaosong
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 135 : 154 - 163
  • [30] Dynamic performance of a novel solar photovoltaic/loop-heat-pipe heat pump system
    Zhang, Xingxing
    Zhao, Xudong
    Shen, Jingchun
    Xu, Jihuan
    Yu, Xiaotong
    [J]. APPLIED ENERGY, 2014, 114 : 335 - 352