Performance investigation of a novel calorimeter for a heat pump system according to flow loops

被引:0
|
作者
Kofi Owura Amoabeng
Kwang Ho Lee
Jong Min Choi
机构
[1] Hanbat National University,Graduate School of Mechanical Engineering
[2] Korea University,Department of Architecture
[3] Hanbat National University,Department of Mechanical Engineering
关键词
Energy savings; Flow configuration; Heat pump; Novel calorimeter; Standard test conditions;
D O I
暂无
中图分类号
学科分类号
摘要
Heat pumps cover a wide range of heating and cooling applications owing to their means of drawing out heat from ground, air and water at low temperature. In order to acquire performance data for heat pump certification and rating, the calorimeter is used in measuring the heat pump. In conventional approach of measuring the heat pump with standard test conditions, a great amount of energy is used in the calorimeter for cooling and heating. Using innovative ways to enhance the calorimeter performance is significant for energy and cost savings. Therefore, a novel calorimeter was developed for heat pump measurement. Two different flow loop configurations, specified as cases (1) and (2) were adopted. In the case (1), secondary fluid flow through the heat recovery unit was directly from heat pump test unit heat exchanger while in case (2), secondary fluid flow through heat recovery unit was from constant temperature water bath directly. The energy usage of the novel calorimeter based on the impact of each configuration was analyzed. Experiments were conducted using a water-to-water heat pump unit in heating and cooling approach with variation in operating conditions. Energy analyses based on test data indicated that energy reduction of the novel calorimeter was at least 72 % for heating and 69 % for cooling in relation to energy used in conventional calorimeter. Moreover, for novel calorimeter, case (1) resulted in energy savings of at least 9.1 % for cooling and 13 % for heating in relation to case (2). However, for heat pump units with very low capacities, tests measurements were executed using case (2) configuration because the tests in case (1) resulted in large thermal fluctuations such that the steady operating conditions of the water setpoint temperatures at inlet to the indoor and outdoor heat exchangers of the test unit were unattainable.
引用
收藏
页码:1749 / 1763
页数:14
相关论文
共 50 条
  • [1] Performance investigation of a novel calorimeter for a heat pump system according to flow loops
    Amoabeng, Kofi Owura
    Lee, Kwang Ho
    Choi, Jong Min
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (04) : 1749 - 1763
  • [2] Modeling and Simulation Performance Evaluation of a Proposed Calorimeter for Testing a Heat Pump System
    Amoabeng, Kofi Owura
    Lee, Kwang Ho
    Choi, Jong Min
    [J]. ENERGIES, 2019, 12 (23)
  • [3] A study on the performance of a newly designed heat pump calorimeter
    Amoabeng, Kofi Owura
    Choi, Jong Min
    [J]. APPLIED THERMAL ENGINEERING, 2017, 123 : 216 - 225
  • [4] Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system
    Xie, Ying
    Zhang, Tao
    Liu, Xiaohua
    [J]. ENERGY, 2016, 115 : 446 - 457
  • [5] Performance of a novel dual-heat-source heat pump system
    Hou, Longshu
    Quan, Zhenhua
    Du, Boyao
    Zhao, Yaohua
    [J]. APPLIED THERMAL ENGINEERING, 2023, 230
  • [6] Performance of a novel mechanical ventilation heat recovery heat pump system
    Riffat, SB
    Gillott, MC
    [J]. APPLIED THERMAL ENGINEERING, 2002, 22 (07) : 839 - 845
  • [7] Performance investigation of the heat pump and power generation integration system
    Wu, Zhangxiang
    Zhang, Yufeng
    Deng, Na
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) : 8608 - 8622
  • [8] Performance Analysis on the Optimum Control of a Calorimeter with a Heat Recovery Unit for a Heat Pump
    Amoabeng, Kofi Owura
    Choi, Jong Min
    [J]. ENERGIES, 2018, 11 (09)
  • [9] Experimental investigation on a novel heat pump system based on desiccant coated heat exchangers
    Hua, L. J.
    Jiang, Y.
    Ge, T. S.
    Wang, R. Z.
    [J]. ENERGY, 2018, 142 : 96 - 107
  • [10] Performance investigation of a combined solar thermal heat pump heating system
    Li, Hong
    Sun, Liangliang
    Zhang, Yonggui
    [J]. APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 460 - 468