Effect of Electrical Contact Resistance on the Performance of Cascade Thermoelectric Coolers

被引:0
|
作者
V. Semenyuk
机构
[1] Thermion Company,
来源
关键词
Cascade thermoelectric cooler; electrical contact resistance; performance; measurements;
D O I
暂无
中图分类号
学科分类号
摘要
Performance of low-temperature cascade thermoelectric coolers (TECs) is analyzed with emphasis on the deterioration of electrical contact resistance. Two key characteristics are under consideration: the maximum coefficient of performance at a given temperature difference and the maximum obtainable cooling for the TECs with fixed configuration. The deterioration of these characteristics with increasing of the resistance of electrical contacts is analyzed for the TECs having from two to six stages that are optimized to achieve the temperature differences of 100–150 K with minimal power consumption. The quality of electrical contacts is a crucial factor that greatly affects the performance of the cascade TECs. To maintain the TEC efficiency at an acceptable level, a contact resistance rc in the range from 10−7 Ω cm2 to 10−6 Ω cm2 should be provided, whereas with greater resistance, the TEC performance decreases dramatically, especially for the TECs with thermoelectric (TE) leg height of 0.5 mm and less. The irreversible losses caused by the resistance of the connecting metal strips are analyzed and the thicknesses that should provide an acceptably low rc level are determined for different cascade TECs with typical TE leg dimensions and spacing.
引用
收藏
页码:1870 / 1876
页数:6
相关论文
共 50 条
  • [31] The effect of initial connector insertions on electrical contact resistance
    Jackson, Robert L.
    Ashurst, W. Robert
    Flowers, George T.
    Angadi, Santosh
    Choe, Song-Yul
    Bozack, Michael J.
    PROCEEDINGS OF THE 53RD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2007, : 17 - +
  • [32] Effect of Electrode Contact Resistance on Electrical Field Measurements
    N. I. Zorin
    D. V. Epishkin
    Izvestiya, Physics of the Solid Earth, 2022, 58 : 727 - 733
  • [33] Stable and low contact resistance electrical contacts for high temperature SiGe thermoelectric generators
    Zhang, Bo
    Zheng, Tao
    Wang, Qingxiao
    Guo, Zaibing
    Kim, Moon J.
    Alshareef, Husam N.
    Gnade, Bruce E.
    SCRIPTA MATERIALIA, 2018, 152 : 36 - 39
  • [34] Effect of Electrical Contact Resistance on Performance and Transport Characteristics of Proton Exchange Membrane Fuel Cells
    Li, Shian
    Wei, Rongqiang
    Qi, Yuanxin
    Yang, Guogang
    Shen, Qiuwan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (12): : 11367 - 11378
  • [35] Improvement of Thermal Environment by Thermoelectric Coolers and Numerical Optimization of Thermal Performance
    Wang, Ning
    Li, Xiao-Chun
    Mao, Jun-Fa
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2015, 62 (08) : 2579 - 2586
  • [36] Experiment on thermoelectric coolers' performance using for heat dissipation of satellite CCDs
    Jiang, Shichen
    Hu, Bingting
    Fu, Xin
    Kang, Aofeng
    Dong, Yaohai
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2014, 43 (01): : 123 - 128
  • [37] Ultra-high performance wearable thermoelectric coolers with less materials
    Kishore, Ravi Anant
    Nozariasbmarz, Amin
    Poudel, Bed
    Sanghadasa, Mohan
    Priya, Shashank
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [38] Analyses of the performance and polar characteristics of two-stage thermoelectric coolers
    Xuan, XC
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2002, 17 (05) : 414 - 420
  • [39] Ultra-high performance wearable thermoelectric coolers with less materials
    Ravi Anant Kishore
    Amin Nozariasbmarz
    Bed Poudel
    Mohan Sanghadasa
    Shashank Priya
    Nature Communications, 10
  • [40] Influence of leg geometry configuration and contact resistance on the performance of annular thermoelectric generators
    Zhang, A. B.
    Wang, B. L.
    Pang, D. D.
    Chen, J. B.
    Wang, J.
    Du, J. K.