Determination of Glyphosate in Water Samples by Multi-pumping Flow System Coupled to a Liquid Waveguide Capillary Cell

被引:0
|
作者
Aline S. Silva
Ildikó V. TóTH
Leonardo Pezza
Helena R. Pezza
José L. F. C. Lima
机构
[1] Universidade Estadual Paulista (UNESP),Instituto de Quimica
[2] Universidade do Porto,REQUIMTE, Departamento de Química, Faculdade de Farmÿάia
来源
Analytical Sciences | 2011年 / 27卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A simple screening method was developed for the determination of glyphosate in water samples using a multi-pumping flow system. The proposed method is based on the reaction between glyphosate and p-dimethylaminocinnamaldehyde (p-DAC), in an acid medium where the reaction product can be measured spectrophotometrically at λmax = 495 nm. An experimental design methodology was used to optimize the measurement conditions. The proposed method was applied to the determination of glyphosate in water samples in a concentration range from 0.5 to 10 µg mL-1. The limit of detection and quantification were 0.17 and 0.53 µg mL-1, respectively. The results obtained (88.5 to 104.5%) in recovery studies for the determination of glyphosate in different water samples indicated good accuracy and no matrix effect for the developed method. Samples were also analyzed by a confirmatory HPLC method, and agreement within the two set of results was found.
引用
收藏
页码:1031 / 1036
页数:5
相关论文
共 50 条
  • [41] Exploiting kinetic spectrophotometric determination of captopril, an angiotensin-converting enzyme inhibitor, in a multi-pumping flow system
    Prior, Joao A. V.
    Santos, Joao L. M.
    Lima, Jose L. F. C.
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 183 - 187
  • [42] A multi-pumping flow system for acute toxicity bioassay using the Vibrio fischeri bacteria
    Adame, Andressa
    Rocha, Fabio R. P.
    ANALYTICAL METHODS, 2014, 6 (18) : 7367 - 7373
  • [43] LIQUID-CHROMATOGRAPHIC DETERMINATION OF GLYPHOSATE IN SOIL AND WATER SAMPLES
    GLASS, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 27 - PEST
  • [44] Photochemical micro-digestion in a multi-pumping flow system for phosphorus fractionation in cereals
    Rocha, Diogo L.
    Rocha, Fabio R. P.
    MICROCHEMICAL JOURNAL, 2013, 109 : 139 - 144
  • [45] A Multi-Pumping Flow System with Pulsed Fluidization to Evaluate Soil Capacity for Phosphate Adsorption
    Machado, Jeane M. C.
    Melchert, Wanessa R.
    Zagatto, Elias A. G.
    Kamogawa, Marcos Y.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (07) : 1149 - 1157
  • [46] Application of direct-injection detector integrated with the multi-pumping flow system to photometric stop-flow determination of total iron
    Koronkiewicz, Stanislawa
    Kalinowski, Slawomir
    TALANTA, 2012, 96 : 68 - 74
  • [47] Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index
    Nalewajko-Sieliwoniuk, Edyta
    Iwanowicz, Magdalena
    Kalinowski, Slawomir
    Kojlo, Anatol
    ANALYTICA CHIMICA ACTA, 2016, 911 : 82 - 91
  • [48] A simple and rapid screening method for sulfonamides in honey using a flow injection system coupled to a liquid waveguide capillary cell
    Catelani, Tiago Augusto
    Toth, Ildiko Vargane
    Lima, Jose L. F. C.
    Pezza, Leonardo
    Pezza, Helena Redigolo
    TALANTA, 2014, 121 : 281 - 287
  • [49] Automatic Multi-pumping Flow System for the Chemiluminometric Screening of Scavenging Capacity against Singlet Oxygen
    Silva, Ana F. T.
    Marques, Karine L.
    Santos, Joao L. M.
    Lima, Jose L. F. C.
    ANALYTICAL SCIENCES, 2011, 27 (08) : 827 - 832
  • [50] Spectrophotometric determination of zinc and copper in a multi-syringe flow injection analysis system using a liquid waveguide capillary cell: Application to natural waters
    Pascoa, Ricardo N. M. J.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    TALANTA, 2011, 84 (05) : 1267 - 1272