An ion-selective potentiometric sensor for hexafluoroarsenate

被引:0
|
作者
A. V. Kopytin
A. F. Zhukov
E. G. Il’in
机构
[1] Russian Academy of Sciences,Kurnakov Institute of General and Inorganic Chemistry
[2] Russian Mendeleev University of Chemical Technology,undefined
来源
关键词
ion-selective potentiometric sensors; ion-selective electrode; hexafluoroarsenate; lithium hexafluoroarsenate; coefficient of selectivity; electrode function;
D O I
暂无
中图分类号
学科分类号
摘要
Ion-selective potentiometric sensors (ion selective electrodes, ISEs) based on tetradecylphosphonium hexafluoroarsenate are developed for the determination of AsF6− ions. Their main parameters, such as selectivity, linearity range of response, detection limit, and also the effect of pH on the readings of electrodes are evaluated. The developed electrode demonstrated high selectivity to the AsF6− acido-complex in the presence of various anions. The detection limit goes up with increasing concentration of HF; for fluoridefree neat solutions of LiAsF6, it is 3 × 10−7, pAsF6 = 6.52; at the concentrations of HF 0.1 and 4 M, it is 1.5 × 10−6 M, pAsF6 = 5.82, and 7 × 10−6 M, pAsF6 = 5.15, respectively.
引用
收藏
页码:485 / 487
页数:2
相关论文
共 50 条
  • [21] Paper-Based Ion-Selective Potentiometric Sensors
    Novell, Marta
    Parrilla, Marc
    Crespo, Gaston A.
    Xavier Rius, F.
    Andrade, Francisco J.
    ANALYTICAL CHEMISTRY, 2012, 84 (11) : 4695 - 4702
  • [22] POTENTIOMETRIC DETERMINATION OF PARA URAZINE WITH AN ION-SELECTIVE ELECTRODE
    IZVEKOV, VP
    TOTH, K
    PUNGOR, E
    KUCSERAP.M
    ANALYST, 1972, 97 (1157) : 634 - &
  • [23] POTENTIOMETRIC MEASUREMENT OF COPPER IN SEAWATER WITH ION-SELECTIVE ELECTRODES
    JASINSKI, R
    TRACHTENBERG, I
    ANDRYCHUK, D
    ANALYTICAL CHEMISTRY, 1974, 46 (03) : 364 - 369
  • [24] POTENTIOMETRIC DETERMINATION OF BORON IN SILICON WITH AN ION-SELECTIVE ELECTRODE
    LANZA, P
    BULDINI, PL
    ANALYTICA CHIMICA ACTA, 1975, 75 (01) : 149 - 157
  • [25] Data acquisition system for ion-selective potentiometric sensors
    Filipkowski, Andrzej
    Ogrodzki, Jan
    Opalski, Leszek J.
    Rybaniec, Radoslaw
    Wieczorek, Piotr Z.
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2009, 2009, 7502
  • [26] POTENTIOMETRIC DETERMINATION OF DIAZEPAM WITH A DIAZEPAM ION-SELECTIVE ELECTRODE
    NIE, LH
    LIU, DZ
    YAO, SZ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (04) : 379 - 383
  • [27] POTENTIOMETRIC TITRATION OF BISARENECHROMIUM COMPOUNDS WITH AN ION-SELECTIVE ELECTRODE
    GUREV, IA
    GUREVA, ZM
    SANKOVA, EV
    SIROTKIN, NI
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1985, 40 (12): : 1797 - 1799
  • [29] ION-SELECTIVE ELECTRODE POTENTIOMETRIC DETERMINATION OF CHLORINE IN ROCKS
    BEBESHKO, GI
    NESTERINA, EM
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (06) : 584 - 586
  • [30] POTENTIOMETRIC ION-SELECTIVE, GAS-SELECTIVE, AND BIOSELECTIVE MEMBRANE ELECTRODES
    PRANITIS, DM
    TELTINGDIAZ, M
    MEYERHOFF, ME
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (03) : 163 - 186