Development and applications of k0 based NAA and prompt gamma-ray NAA methods at BARC

被引:0
|
作者
R. Acharya
A. G. C. Nair
K. Sudarshan
A. Goswami
A. V. R. Reddy
机构
[1] Bhabha Atomic Research Centre,Radiochemistry Division
来源
Journal of Radioanalytical and Nuclear Chemistry | 2008年 / 278卷
关键词
Neutron Activation Analysis; Manganese Nodule; Bhabha Atomic Research Centre; North American Shale Composite; Relative Detection Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
A summary of k0-based R&D work on neutron activation analysis (NAA), internal mono standard NAA (IM-NAA) and prompt gamma-ray NAA (PGNAA) is presented. The k0-based NAA was standardized by characterizing irradiation sites of research reactors, validated using reference materials and applied to samples of different origin. Recently IM-NAA method was developed, validated for small and large size samples and applied for the analysis of large size as well as non-standard geometry samples. Studies on PGNAA included characterization of neutron beam, determinations of detection efficiency and prompt k0-factors, and analytical applications.
引用
收藏
页码:617 / 620
页数:3
相关论文
共 50 条
  • [21] USE OF K0 CONCEPT TO CORRECTIONS FOR INTERFERENCES FROM FISSIONABLE NUCLIDES IN REACTOR NAA
    TIAN, WZ
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 111 (02): : 449 - 468
  • [22] A survey of recent k0-NAA developments and applications in Europe
    De Corte, F
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 9 - 16
  • [23] Determination of the neutron spectrum shape parameter α in k0 NAA methodology using covariance analysis
    Dias, Mauro S.
    Cardoso, Vanderlei
    Koskinas, Marina F.
    Yamazaki, Ione M.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 592 - 595
  • [24] Micro-PIXE characterization of reference samples intended for QA/QC of k0 NAA
    T. Bučar
    B. Smodiš
    P. Pelicon
    J. Simčič
    R. Jaćimović
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 789 - 794
  • [25] Optimized data evaluation for k0-based NAA
    van Sluijs, R
    Bossus, DAW
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 239 (03) : 601 - 603
  • [26] Applications of k 0 NAA at FRM II with high f values
    Li, X.
    von Gostomski, Ch Lierse
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) : 457 - 463
  • [27] Multielement determination of typical diet reference materials by neutron-induced prompt gamma-ray analysis using k0 standardization
    Matsue, H
    Yonezawa, C
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 249 (01) : 11 - 14
  • [28] Development of a prompt gamma-ray analysis combined with multiple gamma-ray detection
    Toh, Y
    Oshima, A
    Koizumi, A
    Osa, A
    Kimura, A
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2006, 819 : 603 - +
  • [29] Micro-PIXE characterization of reference samples intended for QA/QC of k0 NAA
    Bucar, T.
    Smodis, B.
    Pelicon, P.
    Simcic, J.
    Jacimovic, R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (03) : 789 - 794
  • [30] Prompt-gamma activation analysis using the k0 approach
    Molnar, GL
    Revay, Z
    Paul, RL
    Lindstrom, RM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 21 - 26