Using field size factors to characterize the in-air fluence of a proton machine with a range shifter

被引:0
|
作者
Jiajian Shen
Jarrod M. Lentz
Yanle Hu
Wei Liu
Danairis Hernandez Morales
Joshua B. Stoker
Martin Bues
机构
[1] Mayo Clinic Arizona,Department of Radiation Oncology
来源
关键词
Proton pencil beam scanning; Range shifter; Field size factor; Double Gaussians fluence; TPS commissioning;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Fluence correction factors for graphite calorimetry in clinical proton beams using Geant4
    Shipley, D. R.
    Lourenco, A. M.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S77 - S78
  • [22] Dosimetric Impact of In-Air Spot Size Variations for Commissioning a Room-Matched Beam Model for Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Giebeler, A.
    Mascia, A.
    Piskulich, F.
    Perles, L.
    Lepage, R.
    Dong, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 112 - +
  • [23] Determination of Spread Out Bragg Peak Factors and Range Shifter Factors From Measured Depth Dose Curves for Passively Scattered Proton Beams
    Sahoo, N.
    Dhanesar, S. K.
    Song, X.
    Poenisch, F.
    Lii, M.
    Li, H.
    Amos, R.
    Wu, R.
    Gillin, M. T.
    Zhu, X. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S849 - S849
  • [24] Effect of source-to-detector distance on the measurement of in-air output factors for very small field sizes in IMRT commissioning
    Harris, T
    Doppke, K
    Jiang, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1272 - 1272
  • [25] Scanning Beam Spot Preservation for Head and Neck Proton Therapy: Machine, Universal, or 3D-Printed Patient-Related Range Shifter?
    Lin, H.
    Shen, J.
    Zhai, H.
    Mcdonough, J.
    Tochner, Z. A.
    Lin, A.
    Deville, C., Jr.
    Both, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E689 - E689
  • [26] Prescribing Image Noise Using Dynamic Fluence Field Optimization: Experimental Results Using a Pre-Clinical Proton CT Scanner
    Dickmann, J.
    Sarosiek, C.
    Rykalin, V.
    Pankuch, M.
    Rit, S.
    Detrich, N.
    Coutrakon, G.
    Johnson, R. P.
    Schulte, R. W.
    Parodi, K.
    Landry, G.
    Dedes, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E293 - E293
  • [27] Technical Note: Machine learning approaches for range and dose verification in proton therapy using proton-induced positron emitters
    Li, Zhongxing
    Wang, Yiang
    Yu, Yajun
    Fan, Kuanjun
    Xing, Lei
    Peng, Hao
    MEDICAL PHYSICS, 2019, 46 (12) : 5748 - 5757
  • [28] A Universal Range Shifter and Range Compensator Can Enable Proton Pencil Beam Scanning Single-Energy Bragg Peak FLASH-RT Treatment Using Current Commercially Available Proton Systems
    Kang, Minglei
    Wei, Shouyi
    Choi, Jehee Isabelle
    Lin, Haibo
    Simone, Charles B., II
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 113 (01): : 203 - 213
  • [29] On the Dependence of Scanned Proton Beam Dose Output Factors on the Field Size and the Accuracy of the Lateral Dose Profiles
    Titt, U.
    Mirkovic, D.
    Anand, A.
    Perles, L.
    Sawakuchi, G.
    Mohan, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [30] Silicon Diode Measurements of Output Field Size Factors for Proton Pencil Beam Scanning with a Dedicated Nozzle
    McGlade, J.
    Lin, L.
    Solberg, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3496 - 3496