Numerical assessment of laminated cantilevered glass plates with point fixings

被引:0
|
作者
Virginio Quaglini
Sara Cattaneo
Luigi Biolzi
机构
[1] Politecnico di Milano,Department of Architecture, Built Environment and Construction Engineering
来源
关键词
Structural glass; Glass balustrade; Bolted connection; Bonded connection; Finite element analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Cantilevered laminated glass plates, used e.g., in balconies and freestanding glass balustrades, are an example of the use of glass in modern architecture as a structural material. In order to fulfil its scope of preventing building occupants from failing out, the cantilevered plate must be able to transfer the loads imposed from the crowd pressure or by people in motion to the main structure of the building. Since a cantilevered plate is critical in the joint, the design of the connection between the glass pane and the supporting structure is of primary importance for the performance of the system. The paper investigates the behaviour of cantilevered laminated glass plates with point joints, accounting for both bolted and adhesively bonded fixings, and different designs of the joint system. The static and impact tests prescribed in the Italian standard UNI 11678 are numerically simulated and the results analysed in terms of the horizontal deflection and maximum peak stress of the glass pane. Under static loads, bonded joints reduce stress concentration and increase the lateral stiffness of the cantilevered plate in comparison to bolted fixings, but the results are highly sensitive to the stiffness of the interlayer. Increasing the vertical distance between the fixing rows is shown to have contrary effects on the stress concentration around bolt holes depending on either static or dynamic loading is considered.
引用
收藏
页码:187 / 204
页数:17
相关论文
共 50 条
  • [21] THE EFFECTIVE THICKNESS OF LAMINATED GLASS PLATES
    Galuppi, Laura
    Royer-Carfagni, Gianni
    JOURNAL OF MECHANICS OF MATERIALS AND STRUCTURES, 2012, 7 (04) : 375 - 400
  • [22] Influence of corner and edge distance of adhesive point-fixings for glass structures
    Dispersyn, Jonas
    Belis, Jan
    De Jaegher, Jolien
    ENGINEERING STRUCTURES, 2015, 105 : 174 - 185
  • [23] Point fixings in annealed and tempered glass structures: Modeling and optimization of bolted connections
    Bernard, Fabrice
    Daudeville, Laurent
    ENGINEERING STRUCTURES, 2009, 31 (04) : 946 - 955
  • [24] Embedded adhesive connection for laminated glass plates
    Zangenberg, J.
    Poulsen, S. H.
    Bagger, A.
    Stang, H.
    Olesen, J. F.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2012, 34 : 68 - 79
  • [25] Laminated glass plates: revealing of nonlinear behavior
    Asik, MZ
    COMPUTERS & STRUCTURES, 2003, 81 (28-29) : 2659 - 2671
  • [26] Soft impact response of laminated glass plates
    Mohagheghian, I
    Wang, Y.
    Zhou, J.
    Guo, X.
    Charalambides, M.
    Yan, Y.
    Dear, J.
    20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [27] Analytical Solution and Exact Effective Thickness of Multilayered Laminated Glass Cantilevered Balustrades
    Haydar, Ali
    Royer-Carfagni, Gianni
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2023, 90 (06):
  • [28] Contrast of a Probabilistic Design Model for Laminated Glass Plates
    Lamela, M. J.
    Fernandez Canteli, A.
    Przybilla, C.
    Menendez, M.
    ADVANCED MATERIALS FORUM VI, PTS 1 AND 2, 2013, 730-732 : 501 - 506
  • [29] Scaling of impact on glass-polyester laminated plates
    Sutherland, L. S.
    Soares, C. Guedes
    MARITIME INDUSTRY, OCEAN ENGINEERING AND COASTAL RESOURCES, VOLS 1 AND 2, 2008, 1-2 : 293 - 299
  • [30] PHASE-FIELD DAMAGE OF LAMINATED GLASS PLATES
    Schmidt, J.
    Zemanova, A.
    ENGINEERING MECHANICS 2019, 2019, 25 : 335 - 338