A new method with variable injection parameters in contrast-enhanced CT: a phantom study for evaluating an aortic peak enhancement

被引:1
|
作者
Terasawa K. [1 ,2 ]
Maruyama A. [3 ]
Tsukimata T. [1 ]
机构
[1] Central Radiology Department, Nagano Red Cross Hospital, 5-22-1, Wakasato, Nagano-shi, 380-8582, Nagano
[2] Graduate School of Health Science, Suzuka University of Medical Science, 1001-1, Kishioka-cho, Suzuka-shi, 510-0293, Mie
[3] Department of Radiology, Nagano Red Cross Hospital, Nagano
关键词
Contrast enhancement; Contrast material; Time-enhancement curve (TEC); Variable injection method (VIM); Variation factor (VF);
D O I
10.1007/s12194-015-0314-5
中图分类号
学科分类号
摘要
Contrast-enhanced CT employs a standard uniphasic single-injection method (SIM), wherein administration is based on two parameters: the iodine administration rate (mgI/s) and the injection duration (s). However, as the SIM uses a fixed iodine administration rate, only a uniform contrast enhancement can be achieved with this method. The iodine administration rate can be increased only by increasing the iodine dose or shortening the injection duration, and no arbitrary adjustments can be made to the peak enhancement characteristics of the time-enhancement curves (TECs) at the fixed injection parameters used in the SIM. To address this problem, we developed a variable injection method (VIM) with a new parameter, the variation factor (VF), to adjust the TECs. A phantom study with the VIM indicated that arbitrary adjustments to the iodine administration rate could be made without changing the injection duration or increasing the iodine load. In our study, VFs of 0.3 and 0.5, which showed earlier achievement of peak enhancements, showed better temporal separation between arterial vasculature and parenchyma or the venous vasculature than that obtained with the SIM. The higher peak enhancement provided by the VF of 0.3 was also considered to improve the contrast in qualitative diagnostic examinations. A VF of 0.5 increased the duration of the enhancement and was considered to produce stable enhancement of contrast in vascular investigations. The VF is now an essential parameter, and the VIM is useful as a reasonable contrast method that may contribute to both improved visualization and improvement in the accuracy of morphologic diagnosis. © 2015, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:248 / 257
页数:9
相关论文
共 50 条
  • [31] Delayed Adverse Reaction to Contrast-enhanced CT: A Prospective Single-Center Study Comparison to Control Group without Enhancement
    Loh, Shaun
    Bagheri, Sepideh
    Katzberg, Richard W.
    Fung, Maxwell A.
    Li, Chin-Shang
    RADIOLOGY, 2010, 255 (03) : 764 - 771
  • [32] Effects of Imaging Parameters on the Quality of Contrast-Enhanced MR Angiography of Cerebral Aneurysms Treated Using Stent-Assisted Coiling: A Phantom Study
    Ikushima, Yoichiro
    Hashido, Takashi
    Watanabe, Yoshiyuki
    Doi, Tsukasa
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (02) : 146 - 151
  • [33] A new unified level set method for semi-automatic liver tumor segmentation on contrast-enhanced CT images
    Li, Bing Nan
    Chui, Chee Kong
    Chang, Stephen
    Ong, Sim Heng
    EXPERT SYSTEMS WITH APPLICATIONS, 2012, 39 (10) : 9661 - 9668
  • [34] Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement
    Camera, Luigi
    D'Ambrosio, Vincenzo
    Pinto, Lorenzo
    Paludi, Adriana
    Liuzzi, Raffaele
    De Cicco, Rossella
    Ponsiglione, Andrea
    Lagnese, Maria Grazia
    Maurea, Simone
    Brunetti, Arturo
    BRITISH JOURNAL OF RADIOLOGY, 2024, 98 (1165): : 114 - 123
  • [35] Acquisition parameters for dual-energy contrast-enhanced digital mammography using a micelle-based all-in-one nanoparticle (AION) contrast agent: a phantom study
    Lau, Kristen C.
    Hsu, Jessica C.
    Naha, Pratap C.
    Chhour, Peter
    Hastings, Renee
    Stein, Joel M.
    McDonald, Elizabeth S.
    Cormode, David P.
    Maidment, Andrew D. A.
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [36] New method of sentinel node detection using a combination of contrast-enhanced ultrasound and dye guidance: an animal study
    Kiyoka Omoto
    Yasuo Hozumi
    Yoshito Nihei
    Yawara Omoto
    Hirobumi Mizunuma
    Hideo Nagai
    Harumi Koibuchi
    Yasutomo Fujii
    Nobuyuki Taniguchi
    Kouichi Itoh
    Journal of Medical Ultrasonics, 2006, 33 (3) : 153 - 158
  • [37] New technique for detecting cracked teeth and evaluating the crack depth by contrast-enhanced cone beam computed tomography: an in vitro study
    Jie Zhou
    Jieni Fu
    Mo Xiao
    Feng Qiao
    Tiantian Fu
    Yangyang Lv
    Fei Wu
    Cuicui Sun
    Peng Li
    Ligeng Wu
    BMC Oral Health, 22
  • [38] New technique for detecting cracked teeth and evaluating the crack depth by contrast-enhanced cone beam computed tomography: an in vitro study
    Zhou, Jie
    Fu, Jieni
    Xiao, Mo
    Qiao, Feng
    Fu, Tiantian
    Lv, Yangyang
    Wu, Fei
    Sun, Cuicui
    Li, Peng
    Wu, Ligeng
    BMC ORAL HEALTH, 2022, 22 (01)
  • [39] Reducing radiation dose for multi-phase contrast-enhanced dual energy renal CT: pilot study evaluating prior iterative reconstruction
    Patrick J. Navin
    Bohyun Kim
    Michael L. Wells
    Ashish Khandelwal
    Ahmed F. Halaweish
    Taylor R. Moen
    Matthew P. Johnson
    Shannon McCollough
    Yong Suk Lee
    Shuai Leng
    Cynthia H. McCollough
    Joel G. Fletcher
    Abdominal Radiology, 2019, 44 : 3350 - 3358
  • [40] Reducing radiation dose for multi-phase contrast-enhanced dual energy renal CT: pilot study evaluating prior iterative reconstruction
    Navin, Patrick J.
    Kim, Bohyun
    Wells, Michael L.
    Khandelwal, Ashish
    Halaweish, Ahmed F.
    Moen, Taylor R.
    Johnson, Matthew P.
    McCollough, Shannon
    Lee, Yong Suk
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    ABDOMINAL RADIOLOGY, 2019, 44 (10) : 3350 - 3358