Performances of rapid and connected salivary RT-LAMP diagnostic test for SARS-CoV-2 infection in ambulatory screening

被引:0
|
作者
Francisco Santos Schneider
Laurence Molina
Marie-Christine Picot
Nicolas L’Helgoualch
Julien Espeut
Pierre Champigneux
Mellis Alali
Julie Baptiste
Lise Cardeur
Christophe Carniel
Martin Davy
Daniel Dedisse
Benjamin Dubuc
Hugo Fenech
Vincent Foulongne
Carole Fruchart Gaillard
Florence Galtier
Alain Makinson
Grégory Marin
Raissa Medina Santos
David Morquin
Alimata Ouedraogo
Alexandra Prieux Lejeune
Marine Quenot
Pierre Keiflin
Francisco Checa Robles
Carolina Rodrigues Rego
Nicolas Salvetat
Charline Trento
Diana Vetter
Franck Molina
Jacques Reynes
机构
[1] Sys2Diag UMR9005 CNRS ALCEN,Clinical Research and Epidemiology Unit, Department of Medical Information, Montpellier University Hospital
[2] SkillCell,INSERM Centre Investigation Clinique 1411
[3] University of Montpellier,PCCEI, Univ Montpellier, INSERM, EFS
[4] University Hospital,CEA, INRAE, Department of Medicines and Healthcare Technologies (DMTS), University of Paris
[5] Vogo,Saclay
[6] Univ Antilles,Infectious Diseases Department
[7] SIMoS,TransVIHMI, IRD, INSERM
[8] Montpellier University Hospital,Department of Biochemistry and Immunology, Institute of Biological Sciences
[9] University of Montpellier,undefined
[10] Federal University of Minas Gerais,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In the context of social events reopening and economic relaunch, sanitary surveillance of SARS-CoV-2 infection is still required. Here, we evaluated the diagnostic performances of a rapid, extraction-free and connected reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay on saliva. Nasopharyngeal (NP) swabs and saliva from 443 outpatients were collected simultaneously and tested by reverse-transcription quantitative PCR (RT-qPCR) as reference standard test. Seventy-one individuals (16.0%) were positive by NP and/or salivary RT-qPCR. Sensitivity and specificity of salivary RT-LAMP were 85.9% (95%CI 77.8–94.0%) and 99.5% (98.7–100%), respectively. Performances were similar for symptomatic and asymptomatic participants. Moreover, SARS-CoV-2 genetic variants were analyzed and no dominant mutation in RT-LAMP primer region was observed during the period of the study. We demonstrated that this RT-LAMP test on self-collected saliva is reliable for SARS-CoV-2 detection. This simple connected test with optional automatic results transfer to health authorities is unique and opens the way to secure professional and social events in actual context of economics restart.
引用
收藏
相关论文
共 50 条
  • [31] Detection of SARS-CoV-2 RNA using RT-LAMP and molecular beacons
    Sherrill-Mix, Scott
    Hwang, Young
    Roche, Aoife M.
    Glascock, Abigail
    Weiss, Susan R.
    Li, Yize
    Haddad, Leila
    Deraska, Peter
    Monahan, Caitlin
    Kromer, Andrew
    Graham-Wooten, Jevon
    Taylor, Louis J.
    Abella, Benjamin S.
    Ganguly, Arupa
    Collman, Ronald G.
    Van Duyne, Gregory D.
    Bushman, Frederic D.
    GENOME BIOLOGY, 2021, 22 (01)
  • [32] Evaluation of SARS-CoV-2 RNA quantification by RT-LAMP compared to RT-qPCR
    Minami, Kenta
    Masutani, Ryota
    Suzuki, Youichi
    Kubota, Meri
    Osaka, Naofumi
    Nakanishi, Toyofumi
    Nakano, Takashi
    Ukimura, Akira
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2021, 27 (07) : 1068 - 1071
  • [33] Diagnostic Tools for Rapid Screening and Detection of SARS-CoV-2 Infection
    Pandey, Satish Kumar
    Mohanta, Girish C.
    Kumar, Vinod
    Gupta, Kuldeep
    VACCINES, 2022, 10 (08)
  • [34] A rapid, specific, extraction-less, and cost-effective RT-LAMP test for the detection of SARS-CoV-2 in clinical specimens
    Marino, Francesco Elia
    Proffitt, Eric
    Joseph, Eugene
    Manoharan, Arun
    PLOS ONE, 2022, 17 (04):
  • [35] Rapid detection of novel coronavirus SARS-CoV-2 by RT-LAMP coupled solid-state nanopores
    Tang, Zifan
    Nouri, Reza
    Dong, Ming
    Yang, Jianbo
    Greene, Wallace
    Zhu, Yusheng
    Yon, Michele
    Nair, Meera Surendran
    Kuchipudi, Suresh, V
    Guan, Weihua
    BIOSENSORS & BIOELECTRONICS, 2022, 197
  • [36] Optimization and clinical validation of dual-target RT-LAMP for SARS-CoV-2
    Mohon, Abu Naser
    Oberding, Lisa
    Hundt, Jana
    van Marle, Guido
    Pabbaraju, Kanti
    Berenger, Byron M.
    Lisboa, Luiz
    Griener, Thomas
    Czub, Markus
    Doolan, Cody
    Servellita, Venice
    Chiu, Charles Y.
    Greninger, Alexander L.
    Jerome, Keith R.
    Pillai, Dylan R.
    JOURNAL OF VIROLOGICAL METHODS, 2020, 286
  • [37] Profiling RT-LAMP tolerance of sequence variation for SARS-CoV-2 RNA detection
    Tamanaha, Esta
    Zhang, Yinhua
    Tanner, Nathan A.
    PLOS ONE, 2022, 17 (03):
  • [38] Detection of SARS-CoV-2 RNA in Urine by RT-LAMP: A Very Rare Finding
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Munoz-Bellido, Juan Luis
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Carbonell, Cristina
    Lopez-Bernus, Amparo
    Marcos, Miguel
    Belhassen-Garcia, Moncef
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (01)
  • [39] Colorimetric RT-LAMP and LAMP-sequencing for Detecting SARS-CoV-2 RNA in Clinical Samples
    Herbst, Konrad
    Meurer, Matthias
    Kirrmaier, Daniel
    Anders, Simon
    Knop, Michael
    Thi, Viet Loan Dao
    BIO-PROTOCOL, 2021, 11 (06):
  • [40] Extraction-Free Colorimetric RT-LAMP Detection of SARS-CoV-2 in Saliva
    Rivas-Macho, Ane
    Sorarrain, Ane
    Marimon, Jose M.
    Goni-de-Cerio, Felipe
    Olabarria, Garbine
    DIAGNOSTICS, 2023, 13 (14)