Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis

被引:0
|
作者
Takaki Miyagawa
Kazu Matsumoto
Shingo Komura
Haruhiko Akiyama
机构
[1] Gifu University School of Medicine,Department of Orthopaedic Surgery
关键词
Finite element analysis; Total hip arthroplasty; Three-dimensional porous structure; Radiolucent line;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [41] Prediction of PD Magnitudes using Three-Dimensional Finite Element Analysis
    Guo, Jim Jun
    Boggs, Steve
    Campbell, Thomas
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 534 - +
  • [42] Clinical and radiological outcomes of total hip arthroplasty using a highly porous titanium cup or a conventional hydroxyapatite-coated titanium cup: A retrospective study in Japanese patients
    Tamaki, Yasuaki
    Goto, Tomohiro
    Takasago, Tomoya
    Wada, Keizo
    Hamada, Daisuke
    Sairyo, Koichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (01) : 163 - 168
  • [43] Prediction of the mechanical response of canine humerus to three-point bending using subject-specific finite element modelling
    Laurent, Cedric P.
    Bohme, Beatrice
    Mengoni, Marlene
    d'Otreppe, Vinciane
    Balligand, Marc
    Ponthot, Jean-Philippe
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (07) : 639 - 649
  • [44] Three-Dimensional Finite Element Analysis of Cement-Cup Junction in Total Hip Prosthesis: Mechanical Stress Distribution, Crack Initiation and Rupture Dynamics
    Bounoua, Noureddine
    Belhouari, Mohamed
    Menni, Younes
    Alkhafaji, Mohammed Ayad
    Bayram, Mustafa
    Ikumapayi, Omolayo M.
    Chamkha, Ali J.
    NANO, 2025, 20 (04)
  • [45] Sagittal pelvic mal-rotation and positioning of the acetabular component in total hip arthroplasty: Three-dimensional computer model analysis
    Tang, W. M.
    Chiu, K. Y.
    Kwan, M. F. Y.
    Ng, T. P.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (06) : 766 - 771
  • [46] Mechanical behaviour investigation of PEEK coated titanium alloys for hip arthroplasty using finite element analysis
    Belwanshi, Manish
    Jayaswal, Pratesh
    Aherwar, Amit
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 2808 - 2817
  • [47] Three-Dimensional Subject-Specific Knee Shape Reconstruction with Asynchronous Fluoroscopy Images Using Statistical Shape Modeling
    Lu, Hsuan-Yu
    Shih, Kao-Shang
    Lin, Cheng-Chung
    Lu, Tung-Wu
    Li, Song-Ying
    Kuo, Hsin-Wen
    Hsu, Horng-Chaung
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [48] Quantification of Patellofemoral Joint Reaction Forces During Functional Activities Using a Subject-Specific Three-Dimensional Model
    Chen, Yu-Jen
    Scher, Irving
    Powers, Christopher M.
    JOURNAL OF APPLIED BIOMECHANICS, 2010, 26 (04) : 415 - 423
  • [49] Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty
    Kazuki Oishi
    Yuji Yamamoto
    Yoshifumi Harada
    Ryo Inoue
    Eiji Sasaki
    Yasuyuki Ishibashi
    Journal of Orthopaedic Surgery and Research, 16
  • [50] Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty
    Oishi, Kazuki
    Yamamoto, Yuji
    Harada, Yoshifumi
    Inoue, Ryo
    Sasaki, Eiji
    Ishibashi, Yasuyuki
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)